Digital indicatorHandling Company
Sanyu Electronics Industry Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Zero point adjustment range | Applicable converter | Number of views | Load display Display range | Load display indicator | Load display Display increment | Load display Over display | Effect of temperature Zero point | Effects of temperature Sensitivity | Decimal point display | Input range | Input filter | Input noise | Bridge power supply | A/D sampling | Status display | Judgment display | Comparator function setting number | Comparator function setting value | Comparator function Hysteresis data setting value | Nonlinearity display | Nonlinearity output | External control function ZERO | External control function HOLD | Front panel sheet key switch function S1/◀ | Output range | Number of outputs | Output resolution | Comparator function Hysteresis time width setting | CHECK |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Csd701b |
Available upon quote |
-0.3mV/V~2.4mV/V |
Up to 4 strain gauge transducers (350Ω) can be connected |
4 times/s (20 times/s switchable) |
-9,999~99,999 |
Red 7 segment LED character height 17mm |
1 (2, 5, 10 switchable) |
-OL" when minus over, "OL" when plus over |
±1μV/℃ (input conversion, when F.S. is set at ±0.5mV/V~3.1mV/V input) |
±0.02%F.S./℃ (input conversion, when F.S. is set at ±0.5mV/V~3.1mV/V input) |
No display, 10^1, 10^2, 10^3, 10^4 switchable |
F.S. can be set with 0.4mV/V~3.1mV/V input (when bridge power supply DC5V) |
1Hz (with digital filter and stabilization filter setting "0") |
±1μVp-p or less (with digital filter and stabilization filter default settings) |
DC10V±0.5V within 60mA (DC2.5V switchable) |
20 times/s |
◎、HOLD、A/Z、CHECK、PEAK |
S1,S2 |
S1,S2 2 points |
-99,999~99,999 (0~99,999 for input mode and discharge mode) |
0~99digits |
0.05% F.S. |
0.05% F.S. |
Same as S2/▲/ZERO key |
Display, comparison output, analog output, BCD output hold |
S1 set value display/set value carry |
DC5V load resistance 5kΩ or more (F.S. set by function) |
Switchable between 4 times/s and 20 times/s (synchronized with display count) |
Approximately 1/10,000 |
0~9.9s |
Approximately 0.4mV/V (Can be set in the range of approximately 0.2mV/V to 1.4mV/V in approximately 0.2mV/V steps) |
|
Csd702 |
Available upon quote |
-0.3mV/V~2.4mV/V |
Up to 4 strain gauge transducers (350Ω) can be connected |
4 times/s (20 times/s switchable) |
-9,999~99,999 |
Red 7 segment LED character height 17mm |
1 (2, 5, 10 switchable) |
-OL" when minus over, "OL" when plus over |
±1μV/℃ (input conversion, when F.S. is set at 0.5mV/V~3.1mV/V input) |
±0.02%F.S./℃ (input conversion, when F.S. is set at 0.5mV/V~3.1mV/V input) |
No display, 10^1, 10^2, 10^3, 10^4 switchable |
F.S. can be set with 0.4mV/V~3.1mV/V input |
1Hz (with digital filter and stabilization filter setting "0") |
±1μVp-p or less (with digital filter and stabilization filter default settings) |
DC5V±0.25V within 60mA |
20 times/s |
HOLD, PEAK |
S1,S2 |
S1,S2 2 points |
-99,999~99,999 |
0~99digits |
0.05% F.S. |
0.1% F.S. |
Same as S2/▲/ZERO key |
Display, comparison output, analog output hold |
S1 set value display/set value carry |
DC2V load resistance 5kΩ or more (F.S. set by function) |
Switchable between 4 times/s and 20 times/s (synchronized with display count) |
Approximately 1/10,000 |
0~9.9s |
- | |
Csd814b |
Available upon quote |
±2.4mV/V |
Up to 4 strain gauge transducers (350Ω) can be connected |
4 times/s (20 times/s possible depending on settings) |
-1,000~11,000 (×2, ×5, ×10 possible), -11,000~11,000 (×2, ×5, ×10 possible when +/- display mode is set with function setting) |
Green 7-segment fluorescent display tube, character height 22mm |
- |
-OL" when minus over, "OL" when plus over |
±0.2μV/℃ (input conversion) |
±0.0015%F.S./℃ |
No display, 10^1, 10^2, 10^3, 10^4 (can be changed) |
±F.S. can be set with 0.3mV/V~3mV/V input (when +/- display mode is selected in function settings) (when bridge power supply DC10V) |
- | - |
DC10V±0.3V within 120mA (DC2.5V, 5V switchable) With remote sensing |
100 times/s |
RUN, A/Z (auto zero), LOCK, HOLD, CHECK |
S0,S1,S2,S3,S4 |
S1,S2,S3,S4 4 points |
-999,999~999,999 |
0~99digits (When setting increment, this setting value is ×2, ×5, ×10 respectively) |
- | - |
Same as ZERO key + SHIFT key |
Display, comparison output, BCD output (sold separately), current output (sold separately), voltage output (sold separately) hold |
- | - | - | - |
0~9.9s |
Approximately 0.3mV/V 1 point |
|
Csd815b |
Available upon quote |
±2.4mV/V |
Up to 4 strain gauge transducers (350Ω) can be connected |
4 times/s (switchable 20 times/s, 50 times/s, 100 times/s) |
-99,999~99,999 |
Red 7 segment LED character height 17mm |
1 (2, 5, 10 switchable) |
-OL" when minus over, "OL" when plus over |
±0.5μV/℃ (input conversion, when F.S. is set at ±0.5mV/V~3.1mV/V input) |
±0.01%F.S./℃ (input conversion, when F.S. is set at ±0.5mV/V~3.1mV/V input) |
No display, 10^1, 10^2, 10^3, 10^4 switchable |
F.S. can be set with 0.4mV/V~3.1mV/V input (when bridge power supply DC5V) |
2Hz (10Hz, 100Hz, 2kHz switchable) |
±0.6μVp-p or less (with digital filter and stabilization filter default settings) |
DC5V±0.25V within 60mA (DC2.5V switchable) |
100 times/s |
SEL.1, SEL.2, ◎, HOLD, A/Z, CHECK, PEAK, BOTTOM |
S0,S1,S2 |
S0,S1,S2 3 points |
-99,999~99,999 (0~99,999 for input mode and discharge mode) |
0~99digits |
0.01% F.S. |
0.05% F.S. |
Same as ZERO key |
Display, comparison output, analog output, BCD output, CC-Link load output, RS-232C load output, RS-422/485 load output hold |
S1 set value display/Set value carry/S0 set value display by pressing the shift key at the same time |
DC10V load resistance 5kΩ or more (F.S. set by function) |
4 times/s, 20 times/s, 50 times/s, 100 times/s switchable (synchronized with the number of displays) |
Approximately 1/12,000 |
0~9.9s |
Approximately 0.3mV/V (can be set in the range of approximately 0.1mV/V to 1.5mV/V in approximately 0.1mV/V increments) |
|
Csd903 |
Available upon quote |
±2.5mV/V |
Up to 6 strain gauge transducers (350Ω) can be connected in parallel |
4 times/s (20 times/s switchable) |
-999,999~999,999 |
7-segment green fluorescent display tube, character height 11.55mm, 7 digits |
1 (2,5,10,20,50 switchable) |
-OL" when minus over, "OL" when plus over |
±0.2μV/℃ (When calibrated with input sensitivity of 0.2μV/d or more) |
±0.0015%F.S./℃ (When calibrated with input sensitivity of 0.2μV/d or more) |
No display, 10^1, 10^2, 10^3, 10^4 switchable |
-3.1mV/V~3.1mV/V |
- |
±0.2μVp-p or less (with analog filter, digital filter, and stabilization filter default settings) |
DC10V±0.5V180mA or less with remote sensing |
200 times/s (20 times/s switchable) |
- | - |
S1,S2,S3,S4 4 points |
-999,999~999,999 |
0~99digits |
- | - | - | - | - | - | - | - | - | - | |
Csd904 |
Available upon quote |
±2.5mV/V |
Up to 8 strain gauge transducers (350Ω) can be connected |
5 times/s (15 times/s switchable) |
-999,999~999,999 |
7 segment green fluorescent display tube character height 22mm |
1 (2,5,10,20,50 switchable) |
-OL" when minus over, "OL" when plus over |
±0.2μV/℃ (When calibrated with input sensitivity of 0.2μV/d or more) |
±0.0015%F.S./℃ (When calibrated with input sensitivity of 0.2μV/d or more) |
No display, 10^1, 10^2, 10^3 switchable |
-3.1mV/V~3.1mV/V |
Approximately 1Hz (with digital filter and stabilization filter settings) |
±0.4μVp-p or less (with analog filter, digital filter, and stabilization filter default settings) |
DC5V±0.25V within 120mA With sensing |
15 times/s |
Cumulative, stable, fixed tare subtraction, tare subtraction, gross amount, net amount, zero point |
HI, OK, LO (OK: green fluorescent display tube, HI, LO: orange fluorescent display tube) |
LO, HI 2 points (4 points for input mode and discharge mode: target value, head, pre-quantification, and near zero) |
-999,999~999,999 (0~999,999 for input mode and discharge mode) |
0~99digits |
- | - | - | - | - | - | - | - | - | - | |
Csd912 |
Available upon quote |
±2.5mV/V |
Up to 4 strain gauge transducers (350Ω) can be connected |
4 times/s (20 times/s switchable) |
-999,999~999,999 |
7 segment method Character height 22mm |
1 (2,5,10,20,50 switchable) |
-OL" when minus over, "OL" when plus over |
±0.1μV/℃ (When calibrated with input sensitivity of 0.3μV/d or more) |
±0.0008%F.S./℃ (When calibrated with input sensitivity of 0.3μV/d or more) |
None, 10^1, 10^2, 10^3, 10^4 switchable |
-3.1mV/V~3.1mV/V |
Approximately 4Hz (2, 6, 8, 10, 100Hz switchable) |
±0.2μVp-p or less (with analog filter, digital filter, stabilization filter, and A/D sampling default settings) |
DC12V±0.3V within 140mA (DC3V, 6V switchable) With remote sensing |
200 times/s (1,000 times/s, 100 times/s, 50 times/s, 20 times/s, 10 times/s switchable) |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - |