Product
Digital indicatorHandling Company
Sanyu Electronics Industry Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | A/D sampling | Applicable converter | Bridge power supply | CHECK | Comparator function Hysteresis data setting value | Comparator function Hysteresis time width setting | Comparator function setting number | Comparator function setting value | Decimal point display | Effect of temperature Zero point | Effects of temperature Sensitivity | External control function HOLD | External control function ZERO | Front panel sheet key switch function S1/◀ | Input filter | Input noise | Input range | Judgment display | Load display Display increment | Load display Display range | Load display Over display | Load display indicator | Nonlinearity display | Nonlinearity output | Number of outputs | Number of views | Output range | Output resolution | Status display | Zero point adjustment range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Csd701b |
Available upon quote | 20 times/s | Up to 4 strain gauge transducers (350Ω) can be connected | DC10V±0.5V within 60mA (DC2.5V switchable) | Approximately 0.4mV/V (Can be set in the range of approximately 0.2mV/V to 1.4mV/V in approximately 0.2mV/V steps) | 0~99digits | 0~9.9s | S1,S2 2 points | -99,999~99,999 (0~99,999 for input mode and discharge mode) | No display, 10^1, 10^2, 10^3, 10^4 switchable | ±1μV/℃ (input conversion, when F.S. is set at ±0.5mV/V~3.1mV/V input) | ±0.02%F.S./℃ (input conversion, when F.S. is set at ±0.5mV/V~3.1mV/V input) | Display, comparison output, analog output, BCD output hold | Same as S2/▲/ZERO key | S1 set value display/set value carry | 1Hz (with digital filter and stabilization filter setting "0") | ±1μVp-p or less (with digital filter and stabilization filter default settings) | F.S. can be set with 0.4mV/V~3.1mV/V input (when bridge power supply DC5V) | S1,S2 | 1 (2, 5, 10 switchable) | -9,999~99,999 | -OL" when minus over, "OL" when plus over | Red 7 segment LED character height 17mm | 0.05% F.S. | 0.05% F.S. | Switchable between 4 times/s and 20 times/s (synchronized with display count) | 4 times/s (20 times/s switchable) | DC5V load resistance 5kΩ or more (F.S. set by function) | Approximately 1/10,000 | ◎、HOLD、A/Z、CHECK、PEAK | -0.3mV/V~2.4mV/V | |
Csd702 |
Available upon quote | 20 times/s | Up to 4 strain gauge transducers (350Ω) can be connected | DC5V±0.25V within 60mA | - | 0~99digits | 0~9.9s | S1,S2 2 points | -99,999~99,999 | No display, 10^1, 10^2, 10^3, 10^4 switchable | ±1μV/℃ (input conversion, when F.S. is set at 0.5mV/V~3.1mV/V input) | ±0.02%F.S./℃ (input conversion, when F.S. is set at 0.5mV/V~3.1mV/V input) | Display, comparison output, analog output hold | Same as S2/▲/ZERO key | S1 set value display/set value carry | 1Hz (with digital filter and stabilization filter setting "0") | ±1μVp-p or less (with digital filter and stabilization filter default settings) | F.S. can be set with 0.4mV/V~3.1mV/V input | S1,S2 | 1 (2, 5, 10 switchable) | -9,999~99,999 | -OL" when minus over, "OL" when plus over | Red 7 segment LED character height 17mm | 0.05% F.S. | 0.1% F.S. | Switchable between 4 times/s and 20 times/s (synchronized with display count) | 4 times/s (20 times/s switchable) | DC2V load resistance 5kΩ or more (F.S. set by function) | Approximately 1/10,000 | HOLD, PEAK | -0.3mV/V~2.4mV/V | |
Csd814b |
Available upon quote | 100 times/s | Up to 4 strain gauge transducers (350Ω) can be connected | DC10V±0.3V within 120mA (DC2.5V, 5V switchable) With remote sensing | Approximately 0.3mV/V 1 point | 0~99digits (When setting increment, this setting value is ×2, ×5, ×10 respectively) | 0~9.9s | S1,S2,S3,S4 4 points | -999,999~999,999 | No display, 10^1, 10^2, 10^3, 10^4 (can be changed) | ±0.2μV/℃ (input conversion) | ±0.0015%F.S./℃ | Display, comparison output, BCD output (sold separately), current output (sold separately), voltage output (sold separately) hold | Same as ZERO key + SHIFT key | - | - | - | ±F.S. can be set with 0.3mV/V~3mV/V input (when +/- display mode is selected in function settings) (when bridge power supply DC10V) | S0,S1,S2,S3,S4 | - | -1,000~11,000 (×2, ×5, ×10 possible), -11,000~11,000 (×2, ×5, ×10 possible when +/- display mode is set with function setting) | -OL" when minus over, "OL" when plus over | Green 7-segment fluorescent display tube, character height 22mm | - | - | - | 4 times/s (20 times/s possible depending on settings) | - | - | RUN, A/Z (auto zero), LOCK, HOLD, CHECK | ±2.4mV/V | |
Csd815b |
Available upon quote | 100 times/s | Up to 4 strain gauge transducers (350Ω) can be connected | DC5V±0.25V within 60mA (DC2.5V switchable) | Approximately 0.3mV/V (can be set in the range of approximately 0.1mV/V to 1.5mV/V in approximately 0.1mV/V increments) | 0~99digits | 0~9.9s | S0,S1,S2 3 points | -99,999~99,999 (0~99,999 for input mode and discharge mode) | No display, 10^1, 10^2, 10^3, 10^4 switchable | ±0.5μV/℃ (input conversion, when F.S. is set at ±0.5mV/V~3.1mV/V input) | ±0.01%F.S./℃ (input conversion, when F.S. is set at ±0.5mV/V~3.1mV/V input) | Display, comparison output, analog output, BCD output, CC-Link load output, RS-232C load output, RS-422/485 load output hold | Same as ZERO key | S1 set value display/Set value carry/S0 set value display by pressing the shift key at the same time | 2Hz (10Hz, 100Hz, 2kHz switchable) | ±0.6μVp-p or less (with digital filter and stabilization filter default settings) | F.S. can be set with 0.4mV/V~3.1mV/V input (when bridge power supply DC5V) | S0,S1,S2 | 1 (2, 5, 10 switchable) | -99,999~99,999 | -OL" when minus over, "OL" when plus over | Red 7 segment LED character height 17mm | 0.01% F.S. | 0.05% F.S. | 4 times/s, 20 times/s, 50 times/s, 100 times/s switchable (synchronized with the number of displays) | 4 times/s (switchable 20 times/s, 50 times/s, 100 times/s) | DC10V load resistance 5kΩ or more (F.S. set by function) | Approximately 1/12,000 | SEL.1, SEL.2, ◎, HOLD, A/Z, CHECK, PEAK, BOTTOM | ±2.4mV/V | |
Csd903 |
Available upon quote | 200 times/s (20 times/s switchable) | Up to 6 strain gauge transducers (350Ω) can be connected in parallel | DC10V±0.5V180mA or less with remote sensing | - | 0~99digits | - | S1,S2,S3,S4 4 points | -999,999~999,999 | No display, 10^1, 10^2, 10^3, 10^4 switchable | ±0.2μV/℃ (When calibrated with input sensitivity of 0.2μV/d or more) | ±0.0015%F.S./℃ (When calibrated with input sensitivity of 0.2μV/d or more) | - | - | - | - | ±0.2μVp-p or less (with analog filter, digital filter, and stabilization filter default settings) | -3.1mV/V~3.1mV/V | - | 1 (2,5,10,20,50 switchable) | -999,999~999,999 | -OL" when minus over, "OL" when plus over | 7-segment green fluorescent display tube, character height 11.55mm, 7 digits | - | - | - | 4 times/s (20 times/s switchable) | - | - | - | ±2.5mV/V | |
Csd904 |
Available upon quote | 15 times/s | Up to 8 strain gauge transducers (350Ω) can be connected | DC5V±0.25V within 120mA With sensing | - | 0~99digits | - | LO, HI 2 points (4 points for input mode and discharge mode: target value, head, pre-quantification, and near zero) | -999,999~999,999 (0~999,999 for input mode and discharge mode) | No display, 10^1, 10^2, 10^3 switchable | ±0.2μV/℃ (When calibrated with input sensitivity of 0.2μV/d or more) | ±0.0015%F.S./℃ (When calibrated with input sensitivity of 0.2μV/d or more) | - | - | - | Approximately 1Hz (with digital filter and stabilization filter settings) | ±0.4μVp-p or less (with analog filter, digital filter, and stabilization filter default settings) | -3.1mV/V~3.1mV/V | HI, OK, LO (OK: green fluorescent display tube, HI, LO: orange fluorescent display tube) | 1 (2,5,10,20,50 switchable) | -999,999~999,999 | -OL" when minus over, "OL" when plus over | 7 segment green fluorescent display tube character height 22mm | - | - | - | 5 times/s (15 times/s switchable) | - | - | Cumulative, stable, fixed tare subtraction, tare subtraction, gross amount, net amount, zero point | ±2.5mV/V | |
Csd912 |
Available upon quote | 200 times/s (1,000 times/s, 100 times/s, 50 times/s, 20 times/s, 10 times/s switchable) | Up to 4 strain gauge transducers (350Ω) can be connected | DC12V±0.3V within 140mA (DC3V, 6V switchable) With remote sensing | - | - | - | - | - | None, 10^1, 10^2, 10^3, 10^4 switchable | ±0.1μV/℃ (When calibrated with input sensitivity of 0.3μV/d or more) | ±0.0008%F.S./℃ (When calibrated with input sensitivity of 0.3μV/d or more) | - | - | - | Approximately 4Hz (2, 6, 8, 10, 100Hz switchable) | ±0.2μVp-p or less (with analog filter, digital filter, stabilization filter, and A/D sampling default settings) | -3.1mV/V~3.1mV/V | - | 1 (2,5,10,20,50 switchable) | -999,999~999,999 | -OL" when minus over, "OL" when plus over | 7 segment method Character height 22mm | - | - | - | 4 times/s (20 times/s switchable) | - | - | - | ±2.5mV/V |
Click on the part number for more information about each product