All Categories
History
Response Rate
100.0%
Response Time
10.0hours
Fast Response
Product
Network equipment media converter DN2800E seriesHandling Company
Daiden Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Delay time (round trip) | TX port compatible connector | TX port compatible cable | TX port compliant standards | TX port maximum transmission distance | TX port transmission speed | TX port transmission code | TX port transmission method | TX port pinout | TX port interface | LED display TXLK/Act | LED display Pow | LED display LPT | LED display FXLK/Act | LED display Auto | FX port Compatible optical fiber | FX port compatible connector | FX port emission center wavelength | FX port emission level | FX port compliant standards | FX port receiving wavelength | FX port light reception level | FX port optical power loss | FX port transmission speed | FX port transmission distance (estimate) | FX port transmission code | FX port transmission method | FX port connector polishing method | FXport interface | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DN2800GE |
$ 248.30〜 |
185 BitTime (1.85μs) or less |
RJ-45 connector |
UTP Cat5 cable or higher |
IEEE802.3u 100BASE-TX |
100m |
100Mbps |
MLT-3 code |
Full duplex method |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 100BASE-TX display - and in two places on the front) |
Lights up when power is supplied (yellow) |
LPT (Link Pass Through) - Lights up when link link is set (yellow) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when far end fault signal is received (green) (Located in 2 places on top - 100BASE-FX display - and front) |
Lights up (yellow) when Autonegotiation (Auto) is set. |
Silica-based multimode optical fiber (bandwidth 500MHz/km or more @1,300nm) |
SC connector (JIS C 5973 F04 type) |
1,260~1,360nm |
-14~-19dBm (62.5μm) |
IEEE802.3u 100BASE-FX |
1,260~1,360nm |
-14~-30dBm |
0~11dB (62.5μm) |
100Mbps |
2m~2km |
NRZI code |
Full duplex method |
PC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN2800SE |
$ 358.80〜 |
185 BitTime (1.85μs) or less |
RJ-45 connector |
UTP Cat5 cable or higher |
IEEE802.3u 100BASE-TX |
100m |
100Mbps |
MLT-3 code |
Full duplex method |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 100BASE-TX display - and in two places on the front) |
Lights up when power is supplied (yellow) |
LPT (Link Pass Through) - Lights up when link link is set (yellow) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when far end fault signal is received (green) (Located in 2 places on top - 100BASE-FX display - and front) |
Lights up (yellow) when Autonegotiation (Auto) is set. |
Silica-based single mode 1.31μm band zero dispersion optical fiber |
SC connector (JIS C 5973 F04 type) |
1,260~1,360nm |
-8~-15dBm |
IEEE802.3u 100BASE-FX |
1,260~1,360nm |
-8~-34dBm |
0~19dB |
100Mbps |
2m~40km |
NRZI code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN2800LE |
$ 608.40〜 |
185 BitTime (1.85μs) or less |
RJ-45 connector |
UTP Cat5 cable or higher |
IEEE802.3u 100BASE-TX |
100m |
100Mbps |
MLT-3 code |
Full duplex method |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 100BASE-TX display - and in two places on the front) |
Lights up when power is supplied (yellow) |
LPT (Link Pass Through) - Lights up when link link is set (yellow) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when far end fault signal is received (green) (Located in 2 places on top - 100BASE-FX display - and front) |
Lights up (yellow) when Autonegotiation (Auto) is set. |
Silica-based single mode 1.31μm band zero dispersion optical fiber |
SC connector (JIS C 5973 F04 type) |
1,260~1,360nm |
0~-5dBm |
IEEE802.3u 100BASE-FX |
1,260~1,360nm |
0~-34dBm |
0~29dB |
100Mbps |
2m~65km |
NRZI code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN2800ZE |
$ 3,728.40〜 |
185 BitTime (1.85μs) or less |
RJ-45 connector |
UTP Cat5 cable or higher |
IEEE802.3u 100BASE-TX |
100m |
100Mbps |
MLT-3 code |
Full duplex method |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 100BASE-TX display - and in two places on the front) |
Lights up when power is supplied (yellow) |
LPT (Link Pass Through) - Lights up when link link is set (yellow) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when far end fault signal is received (green) (Located in 2 places on top - 100BASE-FX display - and front) |
Lights up (yellow) when Autonegotiation (Auto) is set. |
Silica-based single mode 1.31μm band zero dispersion optical fiber or 1.55μm band zero dispersion shifted optical fiber (DSF) |
SC connector (JIS C 5973 F04 type) |
1,480~1,580nm |
|
IEEE802.3u 100BASE-FX |
1,100~1,600nm |
-9~-45dBm |
14~46dB |
100Mbps |
45~170km |
NRZI code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN2800WL3E |
$ 842.40〜 |
185 BitTime (1.85μs) or less |
RJ-45 connector |
UTP Cat5 cable or higher |
IEEE802.3u 100BASE-TX |
100m |
100Mbps |
MLT-3 code |
Full duplex method |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 100BASE-TX display - and in two places on the front) |
Lights up when power is supplied (yellow) |
LPT (Link Pass Through) - Lights up when link link is set (yellow) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when far end fault signal is received (green) (Located in 2 places on top - 100BASE-FX display - and front) |
Lights up (yellow) when Autonegotiation (Auto) is set. |
Silica-based single mode 1.31μm band zero dispersion optical fiber |
SC connector (JIS C 5973 F04 type) |
1,260~1,360nm |
0~-5dBm |
IEEE802.3u 100BASE-FX |
1,480~1,580nm |
0~-34dBm |
0~29dB |
100Mbps |
2m~65km |
NRZI code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
Send/receive connector 1 port |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN2800WL5E |
$ 842.40〜 |
185 BitTime (1.85μs) or less |
RJ-45 connector |
UTP Cat5 cable or higher |
IEEE802.3u 100BASE-TX |
100m |
100Mbps |
MLT-3 code |
Full duplex method |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 100BASE-TX display - and in two places on the front) |
Lights up when power is supplied (yellow) |
LPT (Link Pass Through) - Lights up when link link is set (yellow) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when far end fault signal is received (green) (Located in 2 places on top - 100BASE-FX display - and front) |
Lights up (yellow) when Autonegotiation (Auto) is set. |
Silica-based single mode 1.31μm band zero dispersion optical fiber |
SC connector (JIS C 5973 F04 type) |
1,480~1,580nm |
0~-5dBm |
IEEE802.3u 100BASE-FX |
1,260~1,360nm |
0~-34dBm |
0~29dB |
100Mbps |
2m~65km |
NRZI code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
Send/receive connector 1 port |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN2800WX5E |
$ 1,719.90〜 |
185 BitTime (1.85μs) or less |
RJ-45 connector |
UTP Cat5 cable or higher |
IEEE802.3u 100BASE-TX |
100m |
100Mbps |
MLT-3 code |
Full duplex method |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 100BASE-TX display - and in two places on the front) |
Lights up when power is supplied (yellow) |
LPT (Link Pass Through) - Lights up when link link is set (yellow) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when far end fault signal is received (green) (Located in 2 places on top - 100BASE-FX display - and front) |
Lights up (yellow) when Autonegotiation (Auto) is set. |
Silica-based single mode 1.31μm band zero dispersion optical fiber or 1.55μm band zero dispersion shifted optical fiber (DSF) |
SC connector (JIS C 5973 F04 type) |
1,480~1,520nm |
|
IEEE802.3u 100BASE-FX |
1,580~1,620nm |
-3~-35dBm |
8~35dB |
100Mbps |
25~120km |
NRZI code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
Send/receive connector 1 port |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN2800WX6E |
$ 1,719.90〜 |
185 BitTime (1.85μs) or less |
RJ-45 connector |
UTP Cat5 cable or higher |
IEEE802.3u 100BASE-TX |
100m |
100Mbps |
MLT-3 code |
Full duplex method |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 100BASE-TX display - and in two places on the front) |
Lights up when power is supplied (yellow) |
LPT (Link Pass Through) - Lights up when link link is set (yellow) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when far end fault signal is received (green) (Located in 2 places on top - 100BASE-FX display - and front) |
Lights up (yellow) when Autonegotiation (Auto) is set. |
Silica-based single mode 1.31μm band zero dispersion optical fiber or 1.55μm band zero dispersion shifted optical fiber (DSF) |
SC connector (JIS C 5973 F04 type) |
1,580~1,620nm |
|
IEEE802.3u 100BASE-FX |
1,480~1,520nm |
-3~-35dBm |
8~35dB |
100Mbps |
25~120km |
NRZI code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
Send/receive connector 1 port |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN2800WZ5E |
$ 4,914.00〜 |
185 BitTime (1.85μs) or less |
RJ-45 connector |
UTP Cat5 cable or higher |
IEEE802.3u 100BASE-TX |
100m |
100Mbps |
MLT-3 code |
Full duplex method |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 100BASE-TX display - and in two places on the front) |
Lights up when power is supplied (yellow) |
LPT (Link Pass Through) - Lights up when link link is set (yellow) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when far end fault signal is received (green) (Located in 2 places on top - 100BASE-FX display - and front) |
Lights up (yellow) when Autonegotiation (Auto) is set. |
Silica-based single mode 1.31μm band zero dispersion optical fiber or 1.55μm band zero dispersion shifted optical fiber (DSF) |
SC connector (JIS C 5973 F04 type) |
1,480~1,520nm |
|
IEEE802.3u 100BASE-FX |
1,580~1,620nm |
-10~-44dBm |
15~45dB |
100Mbps |
50~165km |
NRZI code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
Send/receive connector 1 port |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN2800WZ6E |
$ 4,914.00〜 |
185 BitTime (1.85μs) or less |
RJ-45 connector |
UTP Cat5 cable or higher |
IEEE802.3u 100BASE-TX |
100m |
100Mbps |
MLT-3 code |
Full duplex method |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 100BASE-TX display - and in two places on the front) |
Lights up when power is supplied (yellow) |
LPT (Link Pass Through) - Lights up when link link is set (yellow) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when far end fault signal is received (green) (Located in 2 places on top - 100BASE-FX display - and front) |
Lights up (yellow) when Autonegotiation (Auto) is set. |
Silica-based single mode 1.31μm band zero dispersion optical fiber or 1.55μm band zero dispersion shifted optical fiber (DSF) |
SC connector (JIS C 5973 F04 type) |
1,580~1,620nm |
|
IEEE802.3u 100BASE-FX |
1,480~1,520nm |
-10~-44dBm |
15~45dB |
100Mbps |
50~165km |
NRZI code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
Send/receive connector 1 port |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
10.0hrs