Network equipment media converter DN5810E seriesHandling Company
Daiden Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Maximum packet length | TX port compatible connector | TX port compatible cable | TX port compliant standards | TX port maximum transmission distance | TX port transmission speed | TX port transmission code | TX port transmission method | TX port pinout | TX port interface | LED display TX LK/Act | LED display Pow | LED display FX LK/Act | LED display FDX | LED display 1000M | FX port Compatible optical fiber | FX port compatible connector | FX port emission center wavelength | FX port emission level | FX port compliant standards | FX port receiving wavelength | FX port light reception level | FX port optical power loss | FX port transmission speed | FX port transmission distance (estimate) | FX port transmission code | FX port transmission method | FX port connector polishing method | FXport interface | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DN5810GE |
$ 585.00〜 |
1,632Bytes |
RJ-45 connector |
UTP Cat5E or higher (at 1,000M) /Cat5 or higher (at 10M/100M) |
10M: IEEE802.3 10BASE-T |
100m |
10Mbps / 100Mbps / 1,000Mbps |
10M: Manchester code/100M: MLT-3 code/1,000M: PAM-5 code |
Full duplex / half duplex |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 1000BASE-T display - and in two places on the front) |
Lights up (yellow) when power is supplied (internal voltage is normal) /Lights up (yellow) when MC fails (internal voltage is abnormal) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when Signal Detect (green) (located on top - 1000BASE-X display - and in two places on the front) |
UTP side: Lights up during full duplex operation (yellow) |
UTP side: Lights up when operating at 1,000M (yellow) / Blinks when operating at 100M (yellow) / Turns off when operating at 10M or not selected |
Silica-based multimode optical fiber (bandwidth 500MHz/km or more @850nm) |
SC connector (JIS C 5973 F04 type) |
820~860nm |
-4~-9.5dBm |
IEEE802.3z 1000BASE-SX |
770~860nm |
0~-17dBm |
0~7.5dB |
1,000Mbps |
2m~550m |
8B/10B code |
Full duplex method |
PC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN5810SG2E (IEEE802.3z 1000BASE-LX) |
$ 881.40〜 |
1,632Bytes |
RJ-45 connector |
UTP Cat5E or higher (at 1,000M) /Cat5 or higher (at 10M/100M) |
10M: IEEE802.3 10BASE-T |
100m |
10Mbps / 100Mbps / 1,000Mbps |
10M: Manchester code/100M: MLT-3 code/1,000M: PAM-5 code |
Full duplex / half duplex |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 1000BASE-T display - and in two places on the front) |
Lights up (yellow) when power is supplied (internal voltage is normal) /Lights up (yellow) when MC fails (internal voltage is abnormal) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when Signal Detect (green) (located on top - 1000BASE-X display - and in two places on the front) |
UTP side: Lights up during full duplex operation (yellow) |
UTP side: Lights up when operating at 1,000M (yellow) / Blinks when operating at 100M (yellow) / Turns off when operating at 10M or not selected |
Silica-based single mode 1.31μm band zero dispersion optical fiber or silica-based multimode optical fiber (bandwidth 500MHz/km or more @1,300nm) |
SC connector (JIS C 5973 F04 type) |
1,270~1,355nm |
-3~-10dBm |
IEEE802.3z 1000BASE-LX |
1,100~1,600nm |
-3~-20dBm |
0~10dB |
1,000Mbps |
2~550m/2m~15km (SM time) |
8B/10B code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN5810SG2E (IEEE802.3z 1000BASE-X) |
$ 881.40〜 |
1,632Bytes |
RJ-45 connector |
UTP Cat5E or higher (at 1,000M) /Cat5 or higher (at 10M/100M) |
10M: IEEE802.3 10BASE-T |
100m |
10Mbps / 100Mbps / 1,000Mbps |
10M: Manchester code/100M: MLT-3 code/1,000M: PAM-5 code |
Full duplex / half duplex |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 1000BASE-T display - and in two places on the front) |
Lights up (yellow) when power is supplied (internal voltage is normal) /Lights up (yellow) when MC fails (internal voltage is abnormal) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when Signal Detect (green) (located on top - 1000BASE-X display - and in two places on the front) |
UTP side: Lights up during full duplex operation (yellow) |
UTP side: Lights up when operating at 1,000M (yellow) / Blinks when operating at 100M (yellow) / Turns off when operating at 10M or not selected |
Silica-based multimode optical fiber (bandwidth 500MHz/km or more @1,300nm) |
SC connector (JIS C 5973 F04 type) |
1,270~1,355nm |
0~-10dBm |
IEEE802.3z 1000BASE-X |
1,270~1,355nm |
0~-17dBm |
0~7dB |
1,000Mbps |
2m~2km (when using 50μm fiber) /2m~1km (when using 62.5μm fiber) |
8B/10B code |
Full duplex method |
PC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN5810LE |
$ 1,848.60〜 |
1,632Bytes |
RJ-45 connector |
UTP Cat5E or higher (at 1,000M) /Cat5 or higher (at 10M/100M) |
10M: IEEE802.3 10BASE-T |
100m |
10Mbps / 100Mbps / 1,000Mbps |
10M: Manchester code/100M: MLT-3 code/1,000M: PAM-5 code |
Full duplex / half duplex |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 1000BASE-T display - and in two places on the front) |
Lights up (yellow) when power is supplied (internal voltage is normal) /Lights up (yellow) when MC fails (internal voltage is abnormal) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when Signal Detect (green) (located on top - 1000BASE-X display - and in two places on the front) |
UTP side: Lights up during full duplex operation (yellow) |
UTP side: Lights up when operating at 1,000M (yellow) / Blinks when operating at 100M (yellow) / Turns off when operating at 10M or not selected |
Silica-based single mode 1.31μm band zero dispersion optical fiber |
SC connector (JIS C 5973 F04 type) |
1,304.5~1,317.5nm |
|
IEEE802.3z 1000BASE-X |
1,100~1,620nm |
-3~-23dBm |
8~21dB |
1,000Mbps |
15~45km |
8B/10B code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN5810ZE |
$ 4,875.00〜 |
1,632Bytes |
RJ-45 connector |
UTP Cat5E or higher (at 1,000M) /Cat5 or higher (at 10M/100M) |
10M: IEEE802.3 10BASE-T |
100m |
10Mbps / 100Mbps / 1,000Mbps |
10M: Manchester code/100M: MLT-3 code/1,000M: PAM-5 code |
Full duplex / half duplex |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 1000BASE-T display - and in two places on the front) |
Lights up (yellow) when power is supplied (internal voltage is normal) /Lights up (yellow) when MC fails (internal voltage is abnormal) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when Signal Detect (green) (located on top - 1000BASE-X display - and in two places on the front) |
UTP side: Lights up during full duplex operation (yellow) |
UTP side: Lights up when operating at 1,000M (yellow) / Blinks when operating at 100M (yellow) / Turns off when operating at 10M or not selected |
Silica-based single mode 1.31μm band zero dispersion optical fiber or 1.55μm band zero dispersion shifted optical fiber (DSF) |
SC connector (JIS C 5973 F04 type) |
1,480~1,580nm |
|
IEEE802.3z 1000BASE-X |
1,100~1,600nm |
-9~-35dBm |
15~38dB |
1,000Mbps |
50~140km |
8B/10B code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN5810WG3E |
$ 1,053.00〜 |
1,632Bytes |
RJ-45 connector |
UTP Cat5E or higher (at 1,000M) /Cat5 or higher (at 10M/100M) |
10M: IEEE802.3 10BASE-T |
100m |
10Mbps / 100Mbps / 1,000Mbps |
10M: Manchester code/100M: MLT-3 code/1,000M: PAM-5 code |
Full duplex / half duplex |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 1000BASE-T display - and in two places on the front) |
Lights up (yellow) when power is supplied (internal voltage is normal) /Lights up (yellow) when MC fails (internal voltage is abnormal) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when Signal Detect (green) (located on top - 1000BASE-X display - and in two places on the front) |
UTP side: Lights up during full duplex operation (yellow) |
UTP side: Lights up when operating at 1,000M (yellow) / Blinks when operating at 100M (yellow) / Turns off when operating at 10M or not selected |
Silica-based multimode optical fiber (bandwidth 500MHz/km or more @1,300nm) |
SC connector (JIS C 5973 F04 type) |
1,260~1,360nm |
-1~-8dBm |
IEEE802.3z 1000BASE-X |
1,480~1,580nm |
-1~-17dBm |
0~9dB |
1,000Mbps |
2~550m |
8B/10B code |
Full duplex method |
PC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN5810WG5E |
$ 1,053.00〜 |
1,632Bytes |
RJ-45 connector |
UTP Cat5E or higher (at 1,000M) /Cat5 or higher (at 10M/100M) |
10M: IEEE802.3 10BASE-T |
100m |
10Mbps / 100Mbps / 1,000Mbps |
10M: Manchester code/100M: MLT-3 code/1,000M: PAM-5 code |
Full duplex / half duplex |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 1000BASE-T display - and in two places on the front) |
Lights up (yellow) when power is supplied (internal voltage is normal) /Lights up (yellow) when MC fails (internal voltage is abnormal) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when Signal Detect (green) (located on top - 1000BASE-X display - and in two places on the front) |
UTP side: Lights up during full duplex operation (yellow) |
UTP side: Lights up when operating at 1,000M (yellow) / Blinks when operating at 100M (yellow) / Turns off when operating at 10M or not selected |
Silica-based multimode optical fiber (bandwidth 500MHz/km or more @1,300nm) |
SC connector (JIS C 5973 F04 type) |
1,480~1,580nm |
-1~-8dBm |
IEEE802.3z 1000BASE-X |
1,260~1,360nm |
-1~-17dBm |
0~9dB |
1,000Mbps |
2~550m |
8B/10B code |
Full duplex method |
PC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN5810WS3E |
$ 1,246.70〜 |
1,632Bytes |
RJ-45 connector |
UTP Cat5E or higher (at 1,000M) /Cat5 or higher (at 10M/100M) |
10M: IEEE802.3 10BASE-T |
100m |
10Mbps / 100Mbps / 1,000Mbps |
10M: Manchester code/100M: MLT-3 code/1,000M: PAM-5 code |
Full duplex / half duplex |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 1000BASE-T display - and in two places on the front) |
Lights up (yellow) when power is supplied (internal voltage is normal) /Lights up (yellow) when MC fails (internal voltage is abnormal) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when Signal Detect (green) (located on top - 1000BASE-X display - and in two places on the front) |
UTP side: Lights up during full duplex operation (yellow) |
UTP side: Lights up when operating at 1,000M (yellow) / Blinks when operating at 100M (yellow) / Turns off when operating at 10M or not selected |
Silica-based single mode 1.31μm band zero dispersion optical fiber |
SC connector (JIS C 5973 F04 type) |
1,260~1,360nm |
-2~-8dBm |
IEEE802.3z 1000BASE-X |
1,480~1,580nm |
-2~-21dBm |
0~13dB |
1,000Mbps |
2m~25km |
8B/10B code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN5810WS5E |
$ 1,246.70〜 |
1,632Bytes |
RJ-45 connector |
UTP Cat5E or higher (at 1,000M) /Cat5 or higher (at 10M/100M) |
10M: IEEE802.3 10BASE-T |
100m |
10Mbps / 100Mbps / 1,000Mbps |
10M: Manchester code/100M: MLT-3 code/1,000M: PAM-5 code |
Full duplex / half duplex |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 1000BASE-T display - and in two places on the front) |
Lights up (yellow) when power is supplied (internal voltage is normal) /Lights up (yellow) when MC fails (internal voltage is abnormal) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when Signal Detect (green) (located on top - 1000BASE-X display - and in two places on the front) |
UTP side: Lights up during full duplex operation (yellow) |
UTP side: Lights up when operating at 1,000M (yellow) / Blinks when operating at 100M (yellow) / Turns off when operating at 10M or not selected |
Silica-based single mode 1.31μm band zero dispersion optical fiber |
SC connector (JIS C 5973 F04 type) |
1,480~1,580nm |
-2~-8dBm |
IEEE802.3z 1000BASE-X |
1,260~1,360nm |
-2~-21dBm |
0~13dB |
1,000Mbps |
2m~25km |
8B/10B code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
|
DN5810WL3E |
$ 2,028.00〜 |
1,632Bytes |
RJ-45 connector |
UTP Cat5E or higher (at 1,000M) /Cat5 or higher (at 10M/100M) |
10M: IEEE802.3 10BASE-T |
100m |
10Mbps / 100Mbps / 1,000Mbps |
10M: Manchester code/100M: MLT-3 code/1,000M: PAM-5 code |
Full duplex / half duplex |
Auto MDI-X (Automatic sequence switching) |
1 port connector for UTP |
Lights up when receiving an idle signal on the UTP side (green) / Blinks at high speed when transmitting/receiving data (green) / Blinks at low speed when Signal Detect (green) (located on the top - 1000BASE-T display - and in two places on the front) |
Lights up (yellow) when power is supplied (internal voltage is normal) /Lights up (yellow) when MC fails (internal voltage is abnormal) |
Lights up when optical side idle signal is received (green) / High-speed blinking when transmitting/receiving data (green) / Low-speed blinking when Signal Detect (green) (located on top - 1000BASE-X display - and in two places on the front) |
UTP side: Lights up during full duplex operation (yellow) |
UTP side: Lights up when operating at 1,000M (yellow) / Blinks when operating at 100M (yellow) / Turns off when operating at 10M or not selected |
Silica-based single mode 1.31μm band zero dispersion optical fiber |
SC connector (JIS C 5973 F04 type) |
1,260~1,360nm |
|
IEEE802.3z 1000BASE-X |
1,480~1,580nm |
-3~-25dBm |
8~25dB |
1,000Mbps |
15~50km |
8B/10B code |
Full duplex method |
PC, SPC, AdPC, UPC polishing |
1 port each for sending and receiving connectors (2 ports in total) |
Fixing holder, magnet case (fixing holder already installed), AC adapter |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
14.7hrs