Product
Switching adapter SKV30 seriesHandling Company
Taisei Electronics Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Voltage accuracy | Weight (g) | Overcurrent protection | Overvoltage protection | Insulation voltage | Frequency | Operating ambient temperature/humidity | Efficiency (Typ.) | Output current (A) | Output voltage (V) | Cooling method method | Input current (Typ) | Input voltage range | Storage ambient temperature/humidity | Ripple | Noise |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SKV1805 |
Available upon quote |
5V±5% |
Approximately 300 |
Operates at 105% or more of rated current Automatic recovery |
Operates at 115% or more of rated voltage Zener clamp method |
Input-output AC1,000V for 1 minute Cutoff current 10mA / DC500V 50MΩ or more |
50/60Hz (47~63Hz) |
0 ~ 40℃ 20 ~ 90%RH (no condensation) |
72% |
3.5 |
5 |
Natural air cooling |
0.50A |
AC100V (AC85V ~ AC115V) |
-20 ~ 80℃ 20 ~ 90%RH (no condensation) |
100mVp-p |
200mVp-p |
![]() |
SKV1807 |
Available upon quote |
7V±10% |
Approximately 300 |
Operates at 105% or more of rated current Automatic recovery |
Operates at 115% or more of rated voltage Zener clamp method |
Input-output AC1,000V for 1 minute Cutoff current 10mA / DC500V 50MΩ or more |
50/60Hz (47~63Hz) |
0 ~ 40℃ 20 ~ 90%RH (no condensation) |
72% |
2.5 |
7 |
Natural air cooling |
0.50A |
AC100V (AC85V ~ AC115V) |
-20 ~ 80℃ 20 ~ 90%RH (no condensation) |
100mVp-p |
200mVp-p |
![]() |
SKV3012 |
Available upon quote |
12V±5% |
Approximately 300 |
Operates at 105% or more of rated current Automatic recovery |
Operates at 115% or more of rated voltage Zener clamp method |
Input-output AC1,000V for 1 minute Cutoff current 10mA / DC500V 50MΩ or more |
50/60Hz (47~63Hz) |
0 ~ 40℃ 20 ~ 90%RH (no condensation) |
80% |
2.3 |
12 |
Natural air cooling |
0.70A |
AC100V (AC85V ~ AC115V) |
-20 ~ 80℃ 20 ~ 90%RH (no condensation) |
100mVp-p |
200mVp-p |
![]() |
SKV3015 |
Available upon quote |
15V±5% |
Approximately 300 |
Operates at 105% or more of rated current Automatic recovery |
Operates at 115% or more of rated voltage Zener clamp method |
Input-output AC1,000V for 1 minute Cutoff current 10mA / DC500V 50MΩ or more |
50/60Hz (47~63Hz) |
0 ~ 40℃ 20 ~ 90%RH (no condensation) |
80% |
2 |
15 |
Natural air cooling |
0.70A |
AC100V (AC85V ~ AC115V) |
-20 ~ 80℃ 20 ~ 90%RH (no condensation) |
150mVp-p |
300mVp-p |
![]() |
SKV3024 |
Available upon quote |
24V±5% |
Approximately 300 |
Operates at 105% or more of rated current Automatic recovery |
Operates at 115% or more of rated voltage Zener clamp method |
Input-output AC1,000V for 1 minute Cutoff current 10mA / DC500V 50MΩ or more |
50/60Hz (47~63Hz) |
0 ~ 40℃ 20 ~ 90%RH (no condensation) |
80% |
1.25 |
Twenty four |
Natural air cooling |
0.70A |
AC100V (AC85V ~ AC115V) |
-20 ~ 80℃ 20 ~ 90%RH (no condensation) |
150mVp-p |
300mVp-p |