Product
Switching adapter SKY seriesHandling Company
Taisei Electronics Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Cooling method method | Efficiency (Typ.) | Frequency | Input current (Typ) | Input voltage range | Insulation voltage | Noise | Operating ambient temperature/humidity | Output current (A) | Output voltage (V) | Overcurrent protection | Overvoltage protection | Ripple | Storage ambient temperature/humidity | Voltage accuracy | Weight (g) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SKY0503 |
Available upon quote | Natural air cooling | 68% | 50/60Hz (47~63Hz) | 0.15A | AC100V (AC90V ~ AC110V) | Input-output AC1,000V for 1 minute Cutoff current 10mA / DC500V 50MΩ or more | 200mVp-p | 0 ~ 40℃ 20 ~ 90%RH (no condensation) | 1.5 | 3 | Operates at 105% or more of rated current Automatic recovery | Operates at 115% or more of rated voltage Zener clamp method | 100mVp-p | -20 ~ 80℃ 20 ~ 90%RH (no condensation) | 3V±10% | About 77 | |
SKY0533 |
Available upon quote | Natural air cooling | 70% | 50/60Hz (47~63Hz) | 0.15A | AC100V (AC90V ~ AC110V) | Input-output AC1,000V for 1 minute Cutoff current 10mA / DC500V 50MΩ or more | 200mVp-p | 0 ~ 40℃ 20 ~ 90%RH (no condensation) | 1.5 | 3.3 | Operates at 105% or more of rated current Automatic recovery | Operates at 115% or more of rated voltage Zener clamp method | 100mVp-p | -20 ~ 80℃ 20 ~ 90%RH (no condensation) | 3.3V±10% | About 77 | |
SKY0805 |
Available upon quote | Natural air cooling | 72% | 50/60Hz (47~63Hz) | 0.20A | AC100V (AC90V ~ AC110V) | Input-output AC1,000V for 1 minute Cutoff current 10mA / DC500V 50MΩ or more | 200mVp-p | 0 ~ 40℃ 20 ~ 90%RH (no condensation) | 1.5 | 5 | Operates at 105% or more of rated current Automatic recovery | Operates at 115% or more of rated voltage Zener clamp method | 100mVp-p | -20 ~ 80℃ 20 ~ 90%RH (no condensation) | 5V±5% | About 77 | |
SKY1209 |
Available upon quote | Natural air cooling | 75% | 50/60Hz (47~63Hz) | 0.27A | AC100V (AC90V ~ AC110V) | Input-output AC1,000V for 1 minute Cutoff current 10mA / DC500V 50MΩ or more | 200mVp-p | 0 ~ 40℃ 20 ~ 90%RH (no condensation) | 1.3 | 9 | Operates at 105% or more of rated current Automatic recovery | Operates at 115% or more of rated voltage Zener clamp method | 100mVp-p | -20 ~ 80℃ 20 ~ 90%RH (no condensation) | 9V±5% | About 77 | |
SKY1212 |
Available upon quote | Natural air cooling | 80% | 50/60Hz (47~63Hz) | 0.26A | AC100V (AC90V ~ AC110V) | Input-output AC1,000V for 1 minute Cutoff current 10mA / DC500V 50MΩ or more | 200mVp-p | 0 ~ 40℃ 20 ~ 90%RH (no condensation) | 1 | 12 | Operates at 105% or more of rated current Automatic recovery | Operates at 115% or more of rated voltage Zener clamp method | 100mVp-p | -20 ~ 80℃ 20 ~ 90%RH (no condensation) | 12V±5% | About 77 | |
SKY1215 |
Available upon quote | Natural air cooling | 80% | 50/60Hz (47~63Hz) | 0.26A | AC100V (AC90V ~ AC110V) | Input-output AC1,000V for 1 minute Cutoff current 10mA / DC500V 50MΩ or more | 300mVp-p | 0 ~ 40℃ 20 ~ 90%RH (no condensation) | 0.8 | 15 | Operates at 105% or more of rated current Automatic recovery | Operates at 115% or more of rated voltage Zener clamp method | 150mVp-p | -20 ~ 80℃ 20 ~ 90%RH (no condensation) | 15V±5% | About 77 |
Click on the part number for more information about each product