■Summary

This is a 4-unit synthesis device that can efficiently perform pressurized reactions. You can evaluate the effects of temperature, pressure, and catalysts in hydrogenation (hydrogenation) reactions, polymerization reactions, catalytic reactions, carbonylation reactions, autoclaves, and high-temperature/high-pressure reactions. Individual temperature control allows synthesis experiments to be performed under different temperature conditions at the same time, making it useful for new reactions, catalyst development, reaction risk evaluation, and reaction condition studies when developing pharmaceuticals and functional materials.

■Features

The temperature of four pressure-resistant containers can be controlled independently within the range of -10 to 200℃. Temperature gradient control is also possible (°C/min), allowing you to set the temperature increase pattern to the reaction start temperature, cooling for the purpose of crystallization, etc. All lines are independent gas lines. Each reaction vessel has independent pressurization, evacuation, and addition valves to allow reagents to be delivered to the reaction system without cross-contamination. A high-pressure addition unit (optional) allows liquid reagents to be added during pressurized reactions without opening the reaction system. If you want to release the pressure in a pressure-resistant container, use an individual relief valve (optional). Internal pressure is released at the upper limit set pressure. If you want to record pressure increases, use a pressure transmitter (optional). When used in conjunction with temperature measurements (using optional data loggers and chemical thermocouples), conditions before and after reactions can be analyzed. The block has a sensor hole for a chemical thermocouple sensor (optional) for temperature measurement. To prevent condensation, a defrost heater is incorporated and a shutter is installed at the pressure container insertion port. You can switch between two lines: purge gas and reaction gas. Reaction gas purge after inert gas purge and reaction gas introduction during reaction can be performed smoothly. Electrical parts can be prevented from entering flammable and corrosive atmospheres by air purging.

■Pressure-resistant (reaction) container that can be tightened by hand

Three types of pressure containers can be commonly used: with φ30 sensor protection tube, without protection tube, and with φ60 sensor protection tube. It can be tightened by hand and the maximum working pressure is 5MPa.

■Autoclave-on-head pressure container convenient for transportation

It is possible to change to a pressure-resistant container using an on-head type pressure gauge (optional). The pressure-resistant container can be moved while being sealed, and it can be quickly cooled after autoclaving. Maximum working pressure is 5MPa.

  • Product

    Personal organic synthesizer ChemStation PPV-4430/4431/4460 type

Share this product


200+ people viewing

Last viewed: 14 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

3 Models of Personal organic synthesizer ChemStation PPV-4430/4431/4460 type

Click on the part number for more information about each product

Image Part Number Price (excluding tax) High pressure manifold panel Power input/power voltage Mass Reagent addition method Pressure container Temperature setting/display Temperature measurement Temperature control range (aluminum block temperature) Maximum working pressure Stirring settings/display Stirring method Wetted parts material Safety features External dimensions (mm) Pressure display Pressure measurement Rotation speed range (4 x same rotation speed) Synthetic scale Reaction container/number Cooling water connection diameter Operating ambient temperature range Gas replacement Gas pressure reduction/regulation Gas pressurization/pressure regulation

PPV-4430

Available upon quote

PPV-40HP type

13A, 1,300VA・AC100V 50/60Hz

34kg

Addition and evacuation of gaseous reactants, addition of up to 5 mL of liquid reactants under pressure (optional)

HIP-30 type

Sheet key input/digital display (−40.0 to 200.0℃)

The pressure container is equipped with a temperature sensor protection tube, and the aluminum block temperature is equipped with a temperature sensor insertion hole.

-10~200℃ (individual temperature control x 4)
*Requires cooling water circulation device

Less than 1MPa (when using compressed gas/liquefied gas)
Less than 0.2MPa (when using acetylene gas, etc.)
Less than 5MPa (Separate special parts are required for autoclave reaction.)

Volume setting/digital display (20~2,000rpm)

Ferromagnetic magnetic stirrer

SUS316, Perflo® (O-ring), Glass Teflon® (inner container), Fluorocarbon (relief valve seal)

Relief function: Pressure side relief valve (relief pressure: 0.95MPa), option: individual relief valve (0.34~2.41MPa, 2.41~5.16MPa), gas backflow prevention: check valve installed at each gas inlet, etc.

475W×421D×590H

A Bourdon tube pressure gauge is installed independently in each container.

Measurement with pressure transmitter (optional)

50~1,500rpm (at 14mL of water)

Φ30: 14mL (inner volume: 42mL, without temperature sensor protection tube)

Pressure-resistant container・1~4 pieces

Outer diameter 12mm hose port, for silicone hose φ9 x 13mm

5~35℃

With needle valve (2 gas introduction systems, 1 exhaust system), exhaust and inert gas introduction. Leak test possible

Individual pressure adjustment x 4 (fine adjustment possible with needle valve)

Individual pressure adjustment x 4 (fine adjustment possible with needle valve)

PPV-4431

Available upon quote

PPV-40HP type

13A, 1,300VA・AC100V 50/60Hz

34kg

Addition and evacuation of gaseous reactants, addition of up to 5 mL of liquid reactants under pressure (optional)

HIP-30L type

Sheet key input/digital display (−40.0 to 200.0℃)

The pressure container is equipped with a temperature sensor protection tube, and the aluminum block temperature is equipped with a temperature sensor insertion hole.

-10~200℃ (individual temperature control x 4)
*Requires cooling water circulation device

Less than 1MPa (when using compressed gas/liquefied gas)
Less than 0.2MPa (when using acetylene gas, etc.)
Less than 5MPa (Separate special parts are required for autoclave reaction.)

Volume setting/digital display (20~2,000rpm)

Ferromagnetic magnetic stirrer

SUS316, Perflo® (O-ring), Glass Teflon® (inner container), Fluorocarbon (relief valve seal)

Relief function: Pressure side relief valve (relief pressure: 0.95MPa), option: individual relief valve (0.34~2.41MPa, 2.41~5.16MPa), gas backflow prevention: check valve installed at each gas inlet, etc.

475W×421D×590H

A Bourdon tube pressure gauge is installed independently in each container.

Measurement with pressure transmitter (optional)

50~1,500rpm (at 11mL of water)

Φ30: 11mL (inner volume: 33mL, with temperature sensor protection tube)

Pressure-resistant container・1~4 pieces

Outer diameter 12mm hose port, for silicone hose φ9 x 13mm

5~35℃

With needle valve (2 gas introduction systems, 1 exhaust system), exhaust and inert gas introduction. Leak test possible

Individual pressure adjustment x 4 (fine adjustment possible with needle valve)

Individual pressure adjustment x 4 (fine adjustment possible with needle valve)

Personal organic synthesizer ChemStation PPV-4430/4431/4460 type-Part Number-PPV-4460

PPV-4460

Available upon quote

PPV-40HP type

13A, 1,300VA・AC100V 50/60Hz

60kg

Addition and evacuation of gaseous reactants, addition of up to 5 mL of liquid reactants under pressure (optional)

HIP-60 type

Sheet key input/digital display (−40.0 to 200.0℃)

The pressure container is equipped with a temperature sensor protection tube, and the aluminum block temperature is equipped with a temperature sensor insertion hole.

-10~200℃ (individual temperature control x 4)
*Requires cooling water circulation device

Less than 1MPa (when using compressed gas/liquefied gas)
Less than 0.2MPa (when using acetylene gas, etc.)
Less than 5MPa (Separate special parts are required for autoclave reaction.)

Volume setting/digital display (20~2,000rpm)

Ferromagnetic magnetic stirrer

SUS316, Perflo® (O-ring), Glass Teflon® (inner container), Fluorocarbon (relief valve seal)

Relief function: Pressure side relief valve (relief pressure: 0.95MPa), option: individual relief valve (0.34~2.41MPa, 2.41~5.16MPa), gas backflow prevention: check valve installed at each gas inlet, etc.

475W×421D×590H

A Bourdon tube pressure gauge is installed independently in each container.

Measurement with pressure transmitter (optional)

50~1,000rpm (at 63mL of water)

Φ60: 63mL (inner volume: 190mL, with temperature sensor protection tube)

Pressure-resistant container・1~4 pieces

Outer diameter 12mm hose port, for silicone hose φ9 x 13mm

5~35℃

With needle valve (2 gas introduction systems, 1 exhaust system), exhaust and inert gas introduction. Leak test possible

Individual pressure adjustment x 4 (fine adjustment possible with needle valve)

Individual pressure adjustment x 4 (fine adjustment possible with needle valve)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Automatic Chemical Synthesizers Products

Other products of Tokyo Rikakikai Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Tokyo Rikakikai Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

41.4hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree