Earth pressure meter BEM-AHandling Company
KYOWA ELECTRONIC INSTRUMENTS CO., LTDCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Nonlinearity | Temperature effect at zero point | Mass | Allowable overload | Allowable temperature range | Allowable applied voltage | Temperature compensation range | Recommended applied voltage | Rated capacity | Rated output | Output resistance | Temperature effect on output | Input resistance | Hysteresis | Cable |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BEM-A-100KP for 100kPa |
Available upon quote |
Within ±2%RO |
Within ±0.3%RO/℃ |
Approx. 1kg (excluding cable) |
120% |
-20~80℃ |
10V AC or DC |
-15~70℃ |
2~8V AC or DC |
100kPa |
0.5mV/V (1,000×10^-6 strain) or more |
350Ω±1% |
Within ±0.1%/℃ |
350Ω±1% |
Within ±1%RO |
0.5mm2, 4-core chloroprene 1m, outer diameter 8mm, exposed tip |
|
BEM-A-1MP for 1MPa |
Available upon quote |
Within ±1%RO |
Within ±0.2%RO/℃ |
Approx. 1kg (excluding cable) |
120% |
-20~80℃ |
10V AC or DC |
-15~70℃ |
2~8V AC or DC |
1MPa |
1mV/V (2,000×10^-6 strain) or more |
350Ω±1% |
Within ±0.1%/℃ |
350Ω±1% |
Within ±1%RO |
0.5mm2, 4-core chloroprene 1m, outer diameter 8mm, exposed tip |
|
BEM-A-200KP for 200kPa |
Available upon quote |
Within ±2%RO |
Within ±0.3%RO/℃ |
Approx. 1kg (excluding cable) |
120% |
-20~80℃ |
10V AC or DC |
-15~70℃ |
2~8V AC or DC |
200kPa |
0.5mV/V (1,000×10^-6 strain) or more |
350Ω±1% |
Within ±0.1%/℃ |
350Ω±1% |
Within ±1%RO |
0.5mm2, 4-core chloroprene 1m, outer diameter 8mm, exposed tip |
|
BEM-A-500KP for 500kPa |
Available upon quote |
Within ±1%RO |
Within ±0.2%RO/℃ |
Approx. 1kg (excluding cable) |
120% |
-20~80℃ |
10V AC or DC |
-15~70℃ |
2~8V AC or DC |
500kPa |
1mV/V (2,000×10^-6 strain) or more |
350Ω±1% |
Within ±0.1%/℃ |
350Ω±1% |
Within ±1%RO |
0.5mm2, 4-core chloroprene 1m, outer diameter 8mm, exposed tip |
|
BEM-A-50KP for 50kPa |
Available upon quote |
Within ±2%RO |
Within ±0.5%RO/℃ |
Approx. 1kg (excluding cable) |
120% |
-20~80℃ |
10V AC or DC |
-15~70℃ |
2~8V AC or DC |
50kPa |
0.25mV/V (500×10^-6 strain) or more |
350Ω±1% |
Within ±0.1%/℃ |
350Ω±1% |
Within ±1%RO |
0.5mm2, 4-core chloroprene 1m, outer diameter 8mm, exposed tip |