Differential transformer type displacement measuring device KA-SA-KA-SA-005 ±5 mm
Differential transformer type displacement measuring device KA-SA-KA-SA-010 ±10 mm
Differential transformer type displacement measuring device KA-SA-KA-SA-020 ±20 mm
Differential transformer type displacement measuring device KA-SA-KA-SA-030 ±30 mm
Differential transformer type displacement measuring device KA-SA-KA-SA-050 ±50 mm
Differential transformer type displacement measuring device KA-SA-KA-SA-100 ±100 mm
Differential transformer type displacement measuring device KA-SA-KA-SA-150 ±150 mm
Differential transformer type displacement measuring device KA-SA-KYOWA ELECTRONIC INSTRUMENTS CO., LTD

Differential transformer type displacement measuring device KA-SA
KYOWA ELECTRONIC INSTRUMENTS CO., LTD

KYOWA ELECTRONIC INSTRUMENTS CO., LTD's Response Status

Response Rate

100.0%

Response Time

30.3hours

Relatively Fast Response


About This Product

This is a differential transformer type (LVDT) displacement measurement device. It consists of a displacement sensor and a dedicated conditioner.

■Features

・No reaction force measured ・Drip-proof structure (displacement sensor)

  • Product

    Differential transformer type displacement measuring device KA-SA

Share this product


410+ people viewing

Last viewed: 11 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

8 Models of Differential transformer type displacement measuring device KA-SA

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Measurement sensor model Measurement stroke Displacement sensor temperature coefficient Cable between displacement sensor and signal conditioner Displacement sensor withstand voltage test Displacement sensor insulation resistance test Displacement sensor standard mounting bracket Displacement sensor structure Displacement sensor method Displacement sensor excitation Displacement sensor operating temperature range Sold separately Output specifications Signal conditioner model Signal conditioner power supply Signal conditioner weight Signal conditioner withstand voltage test Signal conditioner insulation resistance test Signal conditioner linearity Signal conditioner polarity Signal conditioner responsiveness Signal conditioner paint color Signal conditioner mounting bracket Signal conditioner Excitation signal switching Signal conditioner Excitation signal Signal conditioner operating temperature range Signal conditioner zero adjustment range Signal conditioner span adjustment range Signal conditioner span adjustment switching
Differential transformer type displacement measuring device KA-SA-Part Number-KA-SA-005 ±5 mm

KA-SA-005 ±5 mm

Available upon quote

KA-005

±5 mm

±100 ppm/℃

Only the 5 m pull-out cable of the displacement sensor is connected between the displacement sensor and the signal conditioner to perform adjustment and verification.

Between each line, between each line and case AC 500 V 60 Hz 1 minute

Between each line and between each line and case 500 V DC 100 MΩ or more

LH-16A (1 piece/unit)

Drip-proof structure, cable pull-out

Differential transformer (LVDT)

5 kHz, AC 5 V

-10℃~80℃ (However, no condensation or freezing)

Power cable 0.75SQ-3C-3M

±10 V/±5 mm

SA-DM-K005

AC 100V (AC 90V~138V) 50/60Hz

Approximately 1.3 kg

Between power supply and chassis AC 500 V 60Hz 1 minute

Between power supply and chassis: DC 500 V 25 MΩ or more

Within ±0.5%/All measurement stroke range for each model

Output increases when the core axis is pulled out from the sensor body

0~200Hz (±3dB)

Munsell 5GY7/1.5

H-02 (2 pieces/unit)

The excitation signal can be switched between external and internal using the OSC switch.
EXT: Use external excitation signal
INT: Uses internal excitation signal

5 kHz, AC 5 V

0~50℃

±10%/each model one side measurement stroke

±20%/each model one side measurement stroke

SPAN switch allows switching between factory adjustment and user adjustment
VAL/CAL

Differential transformer type displacement measuring device KA-SA-Part Number-KA-SA-010 ±10 mm

KA-SA-010 ±10 mm

Available upon quote

KA-010

±10 mm

±100 ppm/℃

Only the 5 m pull-out cable of the displacement sensor is connected between the displacement sensor and the signal conditioner to perform adjustment and verification.

Between each line, between each line and case AC 500 V 60 Hz 1 minute

Between each line and between each line and case 500 V DC 100 MΩ or more

LH-16A (1 piece/unit)

Drip-proof structure, cable pull-out

Differential transformer (LVDT)

5 kHz, AC 5 V

-10℃~80℃ (However, no condensation or freezing)

Power cable 0.75SQ-3C-3M

±10 V/±10 mm

SA-DM-K010

AC 100V (AC 90V~138V) 50/60Hz

Approximately 1.3 kg

Between power supply and chassis AC 500 V 60Hz 1 minute

Between power supply and chassis: DC 500 V 25 MΩ or more

Within ±0.5%/All measurement stroke range for each model

Output increases when the core axis is pulled out from the sensor body

0~200Hz (±3dB)

Munsell 5GY7/1.5

H-02 (2 pieces/unit)

The excitation signal can be switched between external and internal using the OSC switch.
EXT: Use external excitation signal
INT: Uses internal excitation signal

5 kHz, AC 5 V

0~50℃

±10%/each model one side measurement stroke

±20%/each model one side measurement stroke

SPAN switch allows switching between factory adjustment and user adjustment
VAL/CAL

Differential transformer type displacement measuring device KA-SA-Part Number-KA-SA-020 ±20 mm

KA-SA-020 ±20 mm

Available upon quote

KA-020

±20 mm

±100 ppm/℃

Only the 5 m pull-out cable of the displacement sensor is connected between the displacement sensor and the signal conditioner to perform adjustment and verification.

Between each line, between each line and case AC 500 V 60 Hz 1 minute

Between each line and between each line and case 500 V DC 100 MΩ or more

LH-16A (1 piece/unit)

Drip-proof structure, cable pull-out

Differential transformer (LVDT)

5 kHz, AC 5 V

-10℃~80℃ (However, no condensation or freezing)

Power cable 0.75SQ-3C-3M

±10 V/±20 mm

SA-DM-K020

AC 100V (AC 90V~138V) 50/60Hz

Approximately 1.3 kg

Between power supply and chassis AC 500 V 60Hz 1 minute

Between power supply and chassis: DC 500 V 25 MΩ or more

Within ±0.5%/All measurement stroke range for each model

Output increases when the core axis is pulled out from the sensor body

0~200Hz (±3dB)

Munsell 5GY7/1.5

H-02 (2 pieces/unit)

The excitation signal can be switched between external and internal using the OSC switch.
EXT: Use external excitation signal
INT: Uses internal excitation signal

5 kHz, AC 5 V

0~50℃

±10%/each model one side measurement stroke

±20%/each model one side measurement stroke

SPAN switch allows switching between factory adjustment and user adjustment
VAL/CAL

Differential transformer type displacement measuring device KA-SA-Part Number-KA-SA-030 ±30 mm

KA-SA-030 ±30 mm

Available upon quote

KA-030

±30 mm

±50 ppm/℃

Only the 5 m pull-out cable of the displacement sensor is connected between the displacement sensor and the signal conditioner to perform adjustment and verification.

Between each line, between each line and case AC 500 V 60 Hz 1 minute

Between each line and between each line and case 500 V DC 100 MΩ or more

LH-16A (1 piece/unit)

Drip-proof structure, cable pull-out

Differential transformer (LVDT)

5 kHz, AC 5 V

-10℃~80℃ (However, no condensation or freezing)

Power cable 0.75SQ-3C-3M

±10 V/±30 mm

SA-DM-K030

AC 100V (AC 90V~138V) 50/60Hz

Approximately 1.3 kg

Between power supply and chassis AC 500 V 60Hz 1 minute

Between power supply and chassis: DC 500 V 25 MΩ or more

Within ±0.5%/All measurement stroke range for each model

Output increases when the core axis is pulled out from the sensor body

0~200Hz (±3dB)

Munsell 5GY7/1.5

H-02 (2 pieces/unit)

The excitation signal can be switched between external and internal using the OSC switch.
EXT: Use external excitation signal
INT: Uses internal excitation signal

5 kHz, AC 5 V

0~50℃

±10%/each model one side measurement stroke

±20%/each model one side measurement stroke

SPAN switch allows switching between factory adjustment and user adjustment
VAL/CAL

Differential transformer type displacement measuring device KA-SA-Part Number-KA-SA-050 ±50 mm

KA-SA-050 ±50 mm

Available upon quote

KA-050

±50 mm

±50 ppm/℃

Only the 5 m pull-out cable of the displacement sensor is connected between the displacement sensor and the signal conditioner to perform adjustment and verification.

Between each line, between each line and case AC 500 V 60 Hz 1 minute

Between each line and between each line and case 500 V DC 100 MΩ or more

LH-16A (1 piece/unit)

Drip-proof structure, cable pull-out

Differential transformer (LVDT)

5 kHz, AC 5 V

-10℃~80℃ (However, no condensation or freezing)

Power cable 0.75SQ-3C-3M

±10V/±50mm

SA-DM-K050

AC 100V (AC 90V~138V) 50/60Hz

Approximately 1.3 kg

Between power supply and chassis AC 500 V 60Hz 1 minute

Between power supply and chassis: DC 500 V 25 MΩ or more

Within ±0.5%/All measurement stroke range for each model

Output increases when the core axis is pulled out from the sensor body

0~200Hz (±3dB)

Munsell 5GY7/1.5

H-02 (2 pieces/unit)

The excitation signal can be switched between external and internal using the OSC switch.
EXT: Use external excitation signal
INT: Uses internal excitation signal

5 kHz, AC 5 V

0~50℃

±10%/each model one side measurement stroke

±20%/each model one side measurement stroke

SPAN switch allows switching between factory adjustment and user adjustment
VAL/CAL

Differential transformer type displacement measuring device KA-SA-Part Number-KA-SA-100 ±100 mm

KA-SA-100 ±100 mm

Available upon quote

KA-100

±100 mm

±50 ppm/℃

Only the 5 m pull-out cable of the displacement sensor is connected between the displacement sensor and the signal conditioner to perform adjustment and verification.

Between each line, between each line and case AC 500 V 60 Hz 1 minute

Between each line and between each line and case 500 V DC 100 MΩ or more

LH-16A (1 piece/unit)

Drip-proof structure, cable pull-out

Differential transformer (LVDT)

5 kHz, AC 5 V

-10℃~80℃ (However, no condensation or freezing)

Power cable 0.75SQ-3C-3M

±10V/±100mm

SA-DM-K100

AC 100V (AC 90V~138V) 50/60Hz

Approximately 1.3 kg

Between power supply and chassis AC 500 V 60Hz 1 minute

Between power supply and chassis: DC 500 V 25 MΩ or more

Within ±0.5%/All measurement stroke range for each model

Output increases when the core axis is pulled out from the sensor body

0~200Hz (±3dB)

Munsell 5GY7/1.5

H-02 (2 pieces/unit)

The excitation signal can be switched between external and internal using the OSC switch.
EXT: Use external excitation signal
INT: Uses internal excitation signal

5 kHz, AC 5 V

0~50℃

±10%/each model one side measurement stroke

±20%/each model one side measurement stroke

SPAN switch allows switching between factory adjustment and user adjustment
VAL/CAL

Differential transformer type displacement measuring device KA-SA-Part Number-KA-SA-150 ±150 mm

KA-SA-150 ±150 mm

Available upon quote

KA-150

±150 mm

±50 ppm/℃

Only the 5 m pull-out cable of the displacement sensor is connected between the displacement sensor and the signal conditioner to perform adjustment and verification.

Between each line, between each line and case AC 500 V 60 Hz 1 minute

Between each line and between each line and case 500 V DC 100 MΩ or more

LH-16A (1 piece/unit)

Drip-proof structure, cable pull-out

Differential transformer (LVDT)

5 kHz, AC 5 V

-10℃~80℃ (However, no condensation or freezing)

Power cable 0.75SQ-3C-3M

±10V/±150mm

SA-DM-K150

AC 100V (AC 90V~138V) 50/60Hz

Approximately 1.3 kg

Between power supply and chassis AC 500 V 60Hz 1 minute

Between power supply and chassis: DC 500 V 25 MΩ or more

Within ±0.5%/All measurement stroke range for each model

Output increases when the core axis is pulled out from the sensor body

0~200Hz (±3dB)

Munsell 5GY7/1.5

H-02 (2 pieces/unit)

The excitation signal can be switched between external and internal using the OSC switch.
EXT: Use external excitation signal
INT: Uses internal excitation signal

5 kHz, AC 5 V

0~50℃

±10%/each model one side measurement stroke

±20%/each model one side measurement stroke

SPAN switch allows switching between factory adjustment and user adjustment
VAL/CAL

Differential transformer type displacement measuring device KA-SA-Part Number-KA-SA-200 ±200 mm

KA-SA-200 ±200 mm

Available upon quote

KA-200

±200 mm

±50 ppm/℃

Only the 5 m pull-out cable of the displacement sensor is connected between the displacement sensor and the signal conditioner to perform adjustment and verification.

Between each line, between each line and case AC 500 V 60 Hz 1 minute

Between each line and between each line and case 500 V DC 100 MΩ or more

LH-16A (1 piece/unit)

Drip-proof structure, cable pull-out

Differential transformer (LVDT)

5 kHz, AC 5 V

-10℃~80℃ (However, no condensation or freezing)

Power cable 0.75SQ-3C-3M

±10V/±200mm

SA-DM-K200

AC 100V (AC 90V~138V) 50/60Hz

Approximately 1.3 kg

Between power supply and chassis AC 500 V 60Hz 1 minute

Between power supply and chassis: DC 500 V 25 MΩ or more

Within ±0.5%/All measurement stroke range for each model

Output increases when the core axis is pulled out from the sensor body

0~200Hz (±3dB)

Munsell 5GY7/1.5

H-02 (2 pieces/unit)

The excitation signal can be switched between external and internal using the OSC switch.
EXT: Use external excitation signal
INT: Uses internal excitation signal

5 kHz, AC 5 V

0~50℃

±10%/each model one side measurement stroke

±20%/each model one side measurement stroke

SPAN switch allows switching between factory adjustment and user adjustment
VAL/CAL

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Displacement Meters Products

Other products of KYOWA ELECTRONIC INSTRUMENTS CO., LTD

Reviews shown here are reviews of companies.


View more products of KYOWA ELECTRONIC INSTRUMENTS CO., LTD

About Company Handling This Product

Response Rate

100.0%


Response Time

30.3hrs

Company Overview

KYOWA ELECTRONIC INSTRUMENTS CO., LTD., founded in 1949 as Kyowa Radio Laboratory Co., Ltd., is a Japanese man...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree