All Categories

History

Hot wind high -performance type J series-SHD-5J
Hot wind high -performance type J series-Suiden Co.,Ltd.

Hot wind high -performance type J series
Suiden Co.,Ltd.

Suiden Co.,Ltd.'s Response Status

Response Rate

100.0%

Response Time

18.8hours

Relatively Fast Response


About This Product

Because it is an inverter control method, 60Hz driving is possible even in 50Hz area. The air volume during manual operation can be switched by adjusting the frequency by the inverter. In addition, the air volume can be adjusted even with a damper. (Adjustable range is 60Hz ~ 30Hz) When the set temperature is changed during autonomous driving, the program is automatically adjusted to the optimal air volume. The troublesome detailed settings are no longer required, making it possible to drive efficiently. Equipped with a simple pro -con function that allows you to operate at the set temperature for each time you have programmed in advance. Product characteristics ・ Equipped with inverter ・ Equipped with autonomous driving function ・ Equipped with a simple professional con ・ Equipped with external device connection terminals as standard ・ Wind volume adjustment damper standard equipment ・ Heater capacity 5kw ~ 15kW Equipped with an external switch, external temperature adjustment system, buzzer, pattlamps that inform you of abnormal driving, and connection terminals to optional remote control Box-J. It has become easier for customers to customize.

  • Product

    Hot wind high -performance type J series

Share this product


340+ people viewing

Last viewed: 2 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

4 Models of Hot wind high -performance type J series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Series division power supply Heater capacity power consumption Current value Temperature adjustment method electronic control P.I.D Control method Non -contact SSC type Inverter control method Manual bumper method Temperature adjustment range including heat circulation One -way discharge success temperature Types and capacity of the electric motor Maximum air volume Maximum static pressure Compatible duct diameter (hot air outlet / suction port) Inspitable maximum allowable temperature (when using circulation) External dimensions (width W x depth D x height H) mass Installation conditions installation location Installation conditions ground Leakage breaker Temperature and humidity of the surrounding environment Power cord condition
Hot wind high -performance type J series-Part Number-SHD-5J

SHD-5J

Available upon quote

J series

3 phase 200V

5kw

5.1kw

15.7A

〇 (60Hz ~ 30Hz)

Room temperature -350 ° C

350 ℃

3φ200 (210W)

5.7㎥ / min

1.2kpa

φ75mm / φ75mm

200 ° C

W670 x D368 x H514mm

36kg

Horizontal installation indoors that are not exposed to rain and wind

Land (D type)

Sensitive current 100mA or more 20A type

0-40 ° C / 80 % RH or less

VCT2.0 Square Mirimeter x 4 core

Hot wind high -performance type J series-Part Number-SHD-7.5J

SHD-7.5J

Available upon quote

J series

3 phase 200V

7.5kw

7.6kw

23A

〇 (60Hz ~ 30Hz)

Room temperature -350 ° C

350 ℃

3φ200 (210W)

5.7㎥ / min

1.2kpa

φ75mm / φ75mm

200 ° C

W670 x D368 x H514mm

38kg

Horizontal installation indoors that are not exposed to rain and wind

Land (D type)

Sensitive current 100mA or more 30A type

0-40 ° C / 80 % RH or less

VCT3.5 square Mirimeter x 4 core

Hot wind high -performance type J series-Part Number-SHD-10J

SHD-10J

Available upon quote

J series

3 phase 200V

10kW

10.3kw

31a

〇 (60Hz ~ 30Hz)

Room temperature -350 ° C

350 ℃

3φ200 (420W)

9.0㎥ / min

1.4kpa

φ100mm / φ100mm

200 ° C

W719 x D396 x H514mm

41kg

Horizontal installation indoors that are not exposed to rain and wind

Land (D type)

Sensitive current 100mA or more 40A type

0-40 ° C / 80 % RH or less

VCT5.5 Square Mirimeter x 4 core

Hot wind high -performance type J series-Part Number-SHD-15J

SHD-15J

Available upon quote

J series

3 phase 200V

15kW

15.5kW

46.5A

〇 (60Hz ~ 30Hz)

Room temperature -350 ° C

350 ℃

3φ200 (580W)

12.0㎥ / min

1.6kpa

φ125mm / φ125mm

200 ° C

W913 x D452 x H553mm

57kg

Horizontal installation indoors that are not exposed to rain and wind

Land (D type)

Sensitive current 100mA or more 60A type

0-40 ° C / 80 % RH or less

VCT14 Square Mirimeter x 4 core

Click on the part number for more information about each product

Other products of Suiden Co.,Ltd.

Reviews shown here are reviews of companies.


View more products of Suiden Co.,Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

18.8hrs

Company Overview

Suiden Co. Ltd, established in 1961 at Osaka, Japan is a manufacturer of industrial air conditioning equipment...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree