Hot wind standard type F series-SHD-1.3FⅡ
Hot wind standard type F series-Suiden Co.,Ltd.

Hot wind standard type F series
Suiden Co.,Ltd.


About This Product

It is an easy -to -see digital display and easy to operate, so it is a hot wind that can be intuitively operated. By using optional devices, it is possible to interlock with other machines and control temperature in the dried furnace. Either ON or OFF timer can be set in 1 minute from 0 minutes to 99 hours 50 minutes. Product characteristics ・ With digital display temperature control function ・ Beautiful hot air electric heater type ・ Adopt reliable seed heater ・ Power supply single phase 100V three -phase 200V ・ Heater capacity 1.3kw ~ 15kW ・ Manual damper air volume adjustment If the temperature is not stable, the P.I.D. constant can be automatically corrected.

  • Product

    Hot wind standard type F series




*Please note that we may not be able to accommodate sample requests.

6 Models of Hot wind standard type F series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Compatible duct diameter (hot air outlet / suction port) Control method Non -contact SSC type Current value (50 / 60Hz) External dimensions (hot air outlet / suction port) External dimensions (width W x depth D x height H) Heater capacity Inspitable maximum allowable temperature (when using circulation) Installation conditions ground Installation conditions installation location Leakage breaker Mobile volume (50 / 60Hz) One -way discharge maximum temperature (Note 1) Power consumption (50 / 60Hz) Power cord condition Series division Static pressure (50 / 60Hz) Temperature adjustment method electronic control P.I.D Temperature adjustment range including heat circulation Temperature and humidity of the surrounding environment Types and capacity (50 / 60Hz) Wind volume adjustment manual damper method mass power supply
Hot wind standard type F series-Part Number-SHD-1.3FⅡ

SHD-1.3FⅡ

Available upon quote φ50mm / φ75mm 13.5 / 13.6a φ48mm / φ73mm W524 x D344 x H469mm 1.3kw 200 ° C Installation (D type) Horizontal installation indoors that are not exposed to rain and wind Sensitive current 100mA or more 20A type 1.7 / 2.1㎥ / min 200 ° C 1.4 / 1.4kw VCT2.0 square Mirimeter x 3 core FⅡ series 333 / 480pa Room temperature -350 ° C 0-40 ° C / 80 % RH or less 1φ100 (45 / 66W) 26kg 100V
Hot wind standard type F series-Part Number-SHD-2FⅡ

SHD-2FⅡ

Available upon quote φ50mm / φ75mm 10.2 / 10.3A φ48mm / φ73mm W524 x D344 x H469mm 2kw 200 ° C Installation (D type) Horizontal installation indoors that are not exposed to rain and wind Sensitive current 100ma or more 15A type 1.7 / 2.1㎥ / min 200 ° C 2.1 / 2.1kw VCT2.0 square Mirimeter x 3 core FⅡ series 333 / 480pa Room temperature -350 ° C 0-40 ° C / 80 % RH or less 1φ200 (47 / 60W) 26kg Single phase 200V
Hot wind standard type F series-Part Number-SHD-4FⅡ

SHD-4FⅡ

Available upon quote φ75mm / φ100mm 12.2 / 12.3A φ73mm / φ98mm W578 × D359 × H522mm 4kw 200 ° C Installation (D type) Horizontal installation indoors that are not exposed to rain and wind Sensitive current 100ma or more 15A type 3.7 / 4.3㎥ / min 300 ° C 4.1 / 4.2kw VCT2.0 Square Mirimeter x 4 core FⅡ series 627 / 882Pa Room temperature -350 ° C 0-40 ° C / 80 % RH or less 1φ200 (110 / 155W) 33kg 3 phase 200V
Hot wind standard type F series-Part Number-SHD-6FⅡ

SHD-6FⅡ

Available upon quote φ75mm / φ100mm 18.0 / 18.1a φ73mm / φ98mm W578 × D359 × H522mm 6kw 200 ° C Installation (D type) Horizontal installation indoors that are not exposed to rain and wind Sensitive current 100mA or more 20A type 3.7 / 4.3㎥ / min 350 ℃ 6.1 / 6.2kw VCT3.5 square Mirimeter x 4 core FⅡ series 627 / 882Pa Room temperature -350 ° C 0-40 ° C / 80 % RH or less 1φ200 (110 / 155W) 33kg 3 phase 200V
Hot wind standard type F series-Part Number-SHD-9FⅡ

SHD-9FⅡ

Available upon quote φ100mm / φ100mm 26.9 / 27.2a φ98mm / φ98mm W612 x D364 x H522mm 9kw 200 ° C Installation (D type) Horizontal installation indoors that are not exposed to rain and wind Sensitive current 100mA or more 30A type 5.0 / 6.0㎥ / min 350 ℃ 9.1 / 9.2kw VCT5.5 Square Mirimeter x 4 core FⅡ series 725 / 1068Pa Room temperature -350 ° C 0-40 ° C / 80 % RH or less 1φ200 (150 / 230W) 35kg 3 phase 200V
Hot wind standard type F series-Part Number-SHD-15FⅢ

SHD-15FⅢ

Available upon quote φ100mm / φ100mm 45.0 / 45.3A φ98mm / φ98mm W922 × D418 × H545mm 15kW 200 ° C Installation (D type) Horizontal installation indoors that are not exposed to rain and wind Sensitive current 100mA or more 60A type 8.0 / 9.0㎥ / min 350 ℃ 15.4 / 15.6kw VCT14 Square Mirimeter x 4 core FⅡ series 1150 / 1650pa Room temperature -350 ° C 0-40 ° C / 80 % RH or less 3φ200 (330 / 440W) 58kg 3 phase 200V

Click on the part number for more information about each product

Other products of Suiden Co.,Ltd.


View more products of Suiden Co.,Ltd.