All Categories
History
Relatively Fast Response
Product
Industrial electronics ClipXHandling Company
Hottinger Brüel & KjærCategories
Usage Scenarios
Electronics & Electrical UseImage | Part Number | Price (excluding tax) | Measurement input | Real-time calculation of equipment Calculation channel-3 | Real-time calculation of equipment Calculation channel-2 | Real-time calculation of equipment Calculation channel-1 | Power consumption (at maximum 24V supply voltage) | Connectable sensors | Signal bandwidth (-3dB) | Supply voltage cutoff | Supply voltage range | Peak value memory number | Peak value memory reference level | Fuse automatic current limiter | Sensor Identification Supported Types | Sensor identification TEDS module spacing (maximum) | Sensor identification | Sampling rate | Galvanic isolation | Active low pass filter | Ethernet (data link) -5 | Ethernet (data link) -4 | Ethernet (data link) -3 | Ethernet (data link) -2 | Ethernet (data link) -1 | ClipX bus (data transfer) -6 | ClipX bus (data transfer) -5 | ClipX bus (data transfer) -4 | ClipX bus (data transfer) -3 | ClipX bus (data transfer) -2 | ClipX bus (data transfer) -1 | A/D converter |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ClipX |
Available upon quote |
1 number (electrically isolated from power supply) |
Features: Matrix calculation (2x2~6x6), 4:1 multiplexer, tolerance range, peak value with capture, trigger, weight checker, auto average/RMS, physical work, etc. |
Update rate: 1ms |
6 |
5W |
4-gauge type/2-gauge type strain gauge, piezoresistive sensor (voltage supply type), potentiometer, resistance thermometer (Pt100), voltage (±10V), current (±20mA) |
Direct voltage sensor excitation (DC): 3,800Hz (without filter), carrier frequency sensor excitation (CF): 200Hz |
24V (-10%): 10ms, 12V (-10%): 1ms (Compliant with PLC standard DIN EN61131-2) |
10~30VDC (nominal (rated) voltage 24V) |
3 (min, max, peak-to-peak) |
All measurement signals, all calculation channels, data from ClipX bus/fieldbus/Ethernet, analog output |
For all input and output signals |
Zero wire TEDS and one wire TEDS |
100m |
TEDS, IEEE 1451.4 |
19,200S/s |
60V (power supply, sensor input, ClipX bus, analog output, between all digital inputs and outputs, between fieldbuses other than PROFIBUS) |
Bessel or Butterworth 6th order, IIR DC: 0.02~3,000, filter OFF (3,800) CF: 0.02~200 |
Maximum cable length to device: 100m |
Cable type: Standard LAN, CAT5S SFTP |
Plug connection: RJ45, 8 pin |
Protocol/Addressing: TCP/IP (Direct IP address or DHCP) |
10Base-T/100Base-TX |
Maximum distance between two modules: 30cm |
Wiring: Wires, twisted in pairs, shielded |
Protocol/Addressing: RS485, Node 1~6 |
Transmission speed: 1kHz, with automatic synchronization |
Data transfer: 1 data value with status (measured value, calculated value, etc.) |
Maximum number of devices: 6 |
32 bit (delta-sigma converter) |
Reviews shown here are reviews of companies.