All Categories

History

16ch Universal Data Acquisition Module QuantumX MX1601B-MX1601B
16ch Universal Data Acquisition Module QuantumX MX1601B-Hottinger Brüel & Kjær

16ch Universal Data Acquisition Module QuantumX MX1601B
Hottinger Brüel & Kjær


About This Product

■16ch/universal data acquisition module QuantumX MX1601B

Attractive price per channel. A 16-channel universal data acquisition system that can accommodate a variety of inputs, allowing you to connect the following sensors and adjust parameters for each channel. ・Normalized voltage (+/-10V or 100mV) ・Normalized current (0 or 4-20mA) ・IEPE/ICP© sensor

■Features

1. High precision ・Accuracy class: 0.03 ・High resolution digital converter (24bit) ・Low pass filter (Bessel, Butterworth, linear) ・Sampling rate: Maximum 20kS/s (all channels) Bandwidth (maximum 3kHz) ・Highly resistant to noise due to the use of electrically isolated channels ・High precision and low noise: Adopts independent channels with galvanic isolation and digital filters 2. Supports various input signals ・16 independent channels ・Voltage input (±100mV; ±10V; ±60V) and current input (20mA) ・Active, current, piezo sensor input (IEPE) ・Voltage input (0.1V to 60V) ・Supports complex measurement tasks: 16 independent channels 3. Easy operation ・Modular amplifier that can combine various input signals ・Push-in terminal allows quick connection ・Rack mountable ・TEDS support ・Various accessories: cables, mounts, drivers, software ・Ethernet and FireWire interface ・Easy to use and easy to use: push-in terminal and TEDS support

  • Product

    16ch Universal Data Acquisition Module QuantumX MX1601B

Share this product


80+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of 16ch Universal Data Acquisition Module QuantumX MX1601B

Image Part Number Price (excluding tax) Power consumption No adjustable applied voltage to sensor Power consumption Adjustable applied voltage to sensor available Connectable sensors Synchronization option PROFINET Synchronization option IRIG-B Synchronization options IEEE1588, NTP Synchronization option EtherCAT® Input Signal bandwidth Supply voltage range (DC) Supply voltage interruption Sensor identification Maximum cable length for TEDS Sensor identification Sensor connection Sensor applied voltage (active sensor) -4 Sensor applied voltage (active sensor) -3 Sensor applied voltage (active sensor) -2 Sensor applied voltage (active sensor) -1 Sampling rate Active low pass filter IEEE1394b FireWire-5 IEEE1394b FireWire-4 IEEE1394b FireWire-3 IEEE1394b FireWire-2 IEEE1394b FireWire-1 Ethernet (data link) -4 Ethernet (data link) -3 Ethernet (data link) -2 Ethernet (data link) -1 A/D converter (per channel)
16ch Universal Data Acquisition Module QuantumX MX1601B-Part Number-MX1601B

MX1601B

Available upon quote

10W

13W

Voltage, current and current-supplied piezoelectric sensors (IEPE)

Ethernet-based Time Sync Protocol

Via CX27C (B000 to B007; B120 to B127)

Via MX440B/840B input channel (IEEE1588 (PTPv2))

IEEE1394b FireWire (QuantumX only, automatic, recommended) (EtherCAT® is a patented registered trademark of Beckhoff Automation GmbH (Germany))

16. Electrically isolated between channels and from the power supply (when using variable sensor applied voltage, remove electrical isolation from the power supply)

3,800Hz (-3dB) with linear phase filter

10~30V (recommended (rated) voltage 24V)

5ms max at 24V

100m

TEDS, IEEE 1451.4

Plug terminal Phoenix contact, FMC-1.5/8-ST-3.5-RF

Channels 9-16 only: Maximum output current: 30mA per channel/total maximum 75mA

Channels 9~16 only: Power supply (DC): 9~29V (voltage supply to module -1V)

Channels 1~8 only: Maximum output power: 0.7W per channel/total maximum 2W

Channels 1~8 only: Adjustable supply voltage (DC): 5~24V, adjustable per channel

Decimal: 0.1~20,000S/s, Standard: 0.1~19,200S/s (Domain setting possible via software, Factory setting: Standard)

Bessel, Butterworth, linear phase, 0.01~3,000Hz (-3dB), filter off

Maximum number of connectable modules (consecutive): 12 (=11 hops) (inter-module synchronization, data link, supply voltage options)

Maximum cable length between connections: 5m (inter-module synchronization, data link, supply voltage options)

Maximum current between modules: 1.5A (inter-module synchronization, data link, supply voltage options)

Baud rate: 400MBaud (approximately 50MBytes/s) (inter-module synchronization, data link, supply voltage options)

IEEE 1394b (HBM modules only) (inter-module synchronization, data link, supply voltage options)

Maximum cable length to module: 100m

Plug connection: 8P8C plug (RJ-45) with twisted pair cable (CAT-5)

Protocol/Addressing: TCP/IP (static IP/DHCP, IPv4/IPv6)

10Base-T/100Base-TX

24Bit Delta Sigma Converter

Other products of Hottinger Brüel & Kjær

Reviews shown here are reviews of companies.


View more products of Hottinger Brüel & Kjær

About Company Handling This Product

Company Overview

HBK, formerly named HBM, is a global ISO9001 and ISO14001-certified company founded in 1950. It is known for p...

See More

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree