Image | Part Number | Price (excluding tax) | Nonlinearity dlin | Limit load EL | Allowable temperature range Btu | Allowable lateral load Elq | Allowable dynamic load Fsrel | Insulation resistance Riso | Accuracy class | Breaking load Ed | Temperature compensation range BT | Material | Minimum load cell verification scale vmin | Maximum allowable applied voltage | Maximum capacity Emax | Sensitivity error under tensile load | Sensitivity error under compressive load | Temperature effect on sensitivity Within permissible temperature range TKc | Temperature effect on sensitivity Within temperature compensation range TKc | Sensitivity Cn | Reference bridge applied voltage Uref | Output resistance R0 | Input resistance RLC | Protection class (IP) | Storage temperature range Btl | Maximum number of load cell graduations nLC | Bridge applied voltage range BU | Hysteresis error dhy | Temperature effect on zero balance-2 TC0 | Temperature effect on zero balance-1 TC0 | Creep, more than 30 minutes dcr |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
U2A |
Available upon quote |
Accuracy grade 0.2: <±0.20%, Accuracy grade 0.1: ±0.10%, Accuracy grade D1: ±0.05% |
Accuracy grade 0.2: 130, Accuracy grade 0.1/D1: 150 (% of Emax) |
-30~+70℃ (-30~+120℃) /-22~185℉ (-22~248℉) (This value differs from the explosion-proof specification. Please refer to the precautions for safe use. please) |
25 (% of Emax) |
Accuracy class 0.2: 100, accuracy class 0.1/D1: 160 (% of Emax) (peak-to-peak according to DIN 50100) |
>5GΩ |
0.2/0.1/D1 |
300 (% of Emax) |
-10~+40℃ (14~104℉) (This value differs from the explosion-proof specification. Please refer to the safety precautions.) |
Edge body: Stainless steel (according to EN 10088-1), Cable outlet: Nickel-plated brass/silicon, Cable covering: Thermoplastic elastomer |
D1: 0.0286 (% of Emax) |
Accuracy class 0.2: 12V, accuracy class 0.1/D1: 18V (values differ from explosion-proof specifications.Please refer to the precautions for safe use) |
Accuracy grade 0.2: 50kg, Accuracy grade 0.1: 100kg~20t, Accuracy grade D1: 500kg~5t |
<±0.20% |
Accuracy grade 0.2: <±1.50%, accuracy grade 0.1/D1: ±0.50% |
±0.10%/10K (The temperature effect data on sensitivity is a typical value. These combined values meet the requirements stipulated by OIML R60.) |
±0.05%/10K (Data on temperature effect on sensitivity is a typical value. These combined values meet the requirements stipulated by OIML R60) |
2mV/V |
5V |
356±0.2Ω (when cable length is less than 12m), 358±0.2Ω (when cable length is 12m), 359±0.2Ω (when cable length is 20m) |
340~550Ω |
IP67 |
-50~+85℃ (-58~185℉) |
Accuracy grade D1: 1,000 |
Accuracy class 0.2: 0.5~10V, accuracy class 0.1/D1: 0.5~12V (values differ from explosion-proof specifications.Please refer to the precautions for safe use) |
Accuracy grade 0.2/0.1: <±0.15%, Accuracy grade D1: ±0.07% (Hysteresis error data is a typical value. These combined values meet the requirements specified by OIML R60) |
Within allowable temperature range ±0.10%/10K |
Within temperature compensation range Accuracy grade 0.2/0.1: ±0.05%/10K, Accuracy grade D1: ±0.04%/10K |
Accuracy grade 0.2/0.1: <±0.06%, accuracy grade D1: ±0.05% |