Tension load cell Robust hanging load cell Z16AHandling Company
Hottinger Brüel & KjærCategories
Image | Part Number | Price (excluding tax) | Nonlinearity dlin | Limit load EL | Mass (G), without cable, approximate | Allowable temperature range Btu | Allowable dynamic load Fsrel | Breaking load Ed | Temperature compensation range BT | Material | Ratio of minimum verification scale Y | Minimum verification scale vmin | Deflection amount at maximum capacity load (approximate) snom | Maximum capacity Emax | Maximum load cell division number nLC | Sensitivity error | Temperature effect on sensitivity TCs | Sensitivity Cn | Reference bridge applied voltage Uref | Output resistance (red-white) | Input resistance (black-blue) RLC | Protection class | Storage temperature range Btl | Bridge applied voltage range BU | Hysteresis error dhy | Temperature effect on zero point TC0 | Cable length 6 wire type | Creep, more than 30 minutes dcr | Accuracy class based on OIMLR60 | Insulation resistance Ris at 100VDC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Z16A |
Available upon quote |
D1: ±0.0300, C3: ±0.0180 (% of Cn/10K) (Temperature effect on sensitivity is the recommended value. These combined values meet the cumulative error requirements specified by OIML R60) |
150 (% of Emax) |
2.3kg |
-30~+70℃ |
70 (% of Emax) (amplitude conditions according to DIN 50100) |
>350 (% of Emax) |
-10~+40℃ |
Straight body and body: Stainless steel (based on EN 10088-1), Cable outlet: Stainless steel (based on EN 10088-1), Cable sealing: VitonⓇ, Cable covering: Thermoplastic elastomer |
D1: 5,000, C3: 10,000 |
D1: 0.0200, C3: 0.0100 (% of Emax) |
D1: 0.20, C3: 0.27mm |
D1: 7.5/15t, C3: 15t |
D1: 1,000, C3: 3,000 |
±0.5% |
D1: ±0.0250, C3: ±0.0080 (% of Cn/10K) (Temperature effect on sensitivity is a recommended value. These combined values meet the cumulative error requirements specified by OIML R60) |
2mV/V (The error in sensitivity and output resistance value does not need to be small. By adjusting the sensitivity and output resistance of each load cell, the indicated value will not be affected even if an unbalanced load is applied.) |
5V |
706±3.5Ω (Option 40m: 711±3.5Ω) |
700±20Ω |
IP68 (load test conditions: 100 hours immersion in a water tank at a depth of 1 m), IP69K (high pressure water, steam jet cleaning) (according to EN 60 529 (IEC 529)) |
-50~+85℃ |
0.5~12V |
D1: ±0.0330, C3: ±0.0170 (% of Cn/10K) (Temperature effect on sensitivity is the recommended value. These combined values meet the cumulative error requirements specified by OIML R60) |
D1: ±0.0285, C3: ±0.0140 (% of Cn/10K) |
For 12m |
D1: ±0.0330, C3: ±0.0167 (% of Cn/10K) |
D1/C3 (PLC=0.7) |
>5GΩ |