All Categories
History
Product
Canister type load cell C16iHandling Company
Hottinger Brüel & KjærCategories
Image | Part Number | Price (excluding tax) | Asynchronous interface | Limit load (EL) | Mass (including cable) (G) (approximate) | Allowable temperature range (Btu) | Allowable dynamic load (Fsrel) | Maximum resolution of measurement signal | Breaking load (Ed) | Temperature compensation range (BT) | Minimum verification scale (vmin) | Deflection amount at maximum capacity load (snom) (approximate) | Maximum capacity Emax | Maximum number of load cell divisions (nLC) | Sensitivity error | Sensitivity (Cn) | Rated current consumption | Reference bridge applied voltage (Uref) | Storage temperature range (BTL) | Baud rate | Bridge applied voltage range (BU) | Filter mode 1 | Filter mode 0 | Bus node | Temperature effect on zero point (TK0) | Sampling rate | Accuracy class based on OIMLR60 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
C16i C3 |
Available upon quote |
RS-485/4-wire (maximum cable length 500m) |
150 (% of Emax) |
2.2~3.8kg |
-20~+70℃ |
70 (% of Emax) (amplitude conditions according to DIN 50100) |
20bit (at 1Hz) |
>350 (% of Emax) |
-10~+40℃ |
0.0083~0.0100 (% of Emax) |
0.65~1.22mm |
20~60t |
3,000 |
±0.03% |
1,000,000digit |
50mA (see power supply table in instruction manual) |
12V (DC) |
-50~+85℃ |
1,200~115,200baud |
8.5~15V (DC) (see power supply table in instruction manual) |
8~3Hz (low pass) |
8~0.05Hz (low pass) |
Max 32 |
±0.0116~±0.0140 (%Cn/10K) |
1~200 (1/sec) |
C3 |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.