Canister type load cell C16AHandling Company
Hottinger Brüel & KjærCategories
Image | Part Number | Price (excluding tax) | Nonlinearity dlin | Limit load EL | Weight (G) (without cable) (approximate) | Allowable temperature range Btu | Allowable dynamic load Fsrel | Insulation resistance Ris | Breaking load Ed | Temperature compensation range BT | Material | Minimum force output return, 30 minutes DR | Ratio of minimum verification scale Y | Minimum verification scale Vmin | Deflection amount at maximum capacity load (approximate) Snom | Maximum capacity Emax | Maximum load cell division number nLC | Sensitivity tolerance | Temperature coefficient for sensitivity TKc | Sensitivity Cn | Reference bridge applied voltage Uref | Output resistance R0 | Input resistance RLC | Protection class | Storage temperature range Btl | Bridge applied voltage range BU | Hysteresis error dhy | Temperature effect on zero point TK0 | Creep, 30 minutes dcr | Accuracy class based on OIML R60 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
C16A |
Available upon quote |
±0.0120~±0.0330 (% of Cn) (The nonlinearity (diin) value is the recommended value. The sum of these values is pLC=0.7, which meets the cumulative error requirement specified by OIML R60) |
150 (% of Emax) |
8~22.0kg |
-50~+70℃ |
70 (% of Emax) (amplitude conditions according to DIN 50100) |
>5GΩ |
>200~>350 (% of Emax) |
-10~+40℃ |
Edge body and main body: Stainless steel (according to EN10088-1), Cable outlet: Stainless steel (according to EN10088-1), Cable sealing: Viton🄬, Cable covering: Thermoplastic elastomer |
±0.0100~±0.0330 (% of Cn) |
5,000~12,000 |
0.0083~0.0200 (% of Emax) |
0.65~2.64mm |
20t~400t |
1,000~5,000 |
±0.5% (The error in sensitivity and output resistance value does not need to be small. By adjusting the sensitivity and output resistance of each load cell, the indicated value will not be affected even if an unbalanced load is applied.) |
±0.0060~±0.0250 (% of Cn/10K) (Temperature effect on sensitivity (TCs) values are recommended values. The sum of these values is pLC=0.7, which satisfies the cumulative error requirement specified by OIML R60. ) |
2mV/V |
5V |
706±3.5Ω (The error in sensitivity and output resistance value does not need to be small. By adjusting the sensitivity and output resistance of each load cell, the indicated value will not be affected even if an unbalanced load is applied.) |
700±20Ω |
IP68 (load test conditions: 100/10,000 hours immersion in a water tank at a depth of 1/2 m), IP69K (high pressure water, steam jet cleaning) (based on EN 60529 (IEC 529)) |
-50~+85℃ |
0.5~12V |
±0.0140~±0.0330 (% of Cn) (The value of hysteresis error (dhy) is the recommended value. The sum of these values is pLC=0.7, which meets the cumulative error requirement specified by OIML R60) |
±0.0116~±0.0285 (Cn%/10K) |
±0.0100~±0.0330 (% of Cn) |
D1/C3/C4/C5 |