All Categories
History
Response Rate
100.0%
Response Time
28.9hours
Relatively Fast Response
Product
2-phase microstep driver SD seriesHandling Company
Vanguard Systems Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Drive method | Power supply current | Weight | Selection function | Applicable motor | Adjustment function STOP | Adjustment function RUN | Adjustment function JOG | Display function | Maximum input pulse frequency | External dimensions | Operating temperature/humidity | Output current | Output signal | Input power voltage | Input signal | Storage temperature/humidity | Current down function | CE mark |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SD4015B3 |
Available upon quote |
Bipolar constant current chopper method |
2A (MAX) when output current is set to 1.5A |
40g |
Number of divisions (1/2, 1/8, 1/10, 1/16, 1/20, 1/32, 1/40, 1/64) Automatic current down enable/disable JOG function MIX::Mix decay ratio setting |
2-phase stepping motor (bipolar type/unipolar type) |
Stop current setting |
Operating current setting (0.25~1.5A) |
Speed setting during JOG operation |
Lights up when power is input |
200Kpps |
W72×D50×H21 |
0~40℃, 35~80% (no condensation) |
0.25~1.5Apeak (±5%) /phase |
Alarm (power element heating detection) Normal: ON/Alarm: OFF |
DC18V~36V |
Command pulse (CW/CCW or PULSE/DIR) Excitation OFF |
-20~+85℃, 35~80% (no condensation) |
Function selection possible with automatic current down switch |
○ |
![]() |
SD4030B3 |
Available upon quote |
Bipolar constant current chopper method |
3A (MAX) When output current is set to 3A |
112g |
Number of divisions (1/2, 1/8, 1/10, 1/16, 1/20, 1/32, 1/40, 1/64) Automatic current down enable/disable JOG function MIX::Mix decay ratio setting |
2-phase stepping motor (bipolar type/unipolar type) |
Stop current setting |
Operating current setting (0.5~3A) |
Speed setting during JOG operation |
Lights up when power is input |
200Kpps |
W90×D55.5×H28 |
0~40℃, 35~80% (no condensation) |
0.5~3Apeak (±5%) /phase |
Alarm (power element heating detection) Normal: ON/Alarm: OFF |
DC18V~36V |
Command pulse (CW/CCW or PULSE/DIR) Excitation OFF |
-20~+85℃, 35~80% (no condensation) |
Function selection possible with automatic current down switch |
○ |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
28.9hrs