Hot wind standard type F series-SHD-1.3FⅡ
Hot wind standard type F series-Suiden Co.,Ltd.

Hot wind standard type F series
Suiden Co.,Ltd.

Suiden Co.,Ltd.'s Response Status

Response Rate

100.0%

Response Time

18.8hours

Relatively Fast Response


About This Product

It is an easy -to -see digital display and easy to operate, so it is a hot wind that can be intuitively operated. By using optional devices, it is possible to interlock with other machines and control temperature in the dried furnace. Either ON or OFF timer can be set in 1 minute from 0 minutes to 99 hours 50 minutes. Product characteristics ・ With digital display temperature control function ・ Beautiful hot air electric heater type ・ Adopt reliable seed heater ・ Power supply single phase 100V three -phase 200V ・ Heater capacity 1.3kw ~ 15kW ・ Manual damper air volume adjustment If the temperature is not stable, the P.I.D. constant can be automatically corrected.

  • Product

    Hot wind standard type F series

Share this product


470+ people viewing

Last viewed: 29 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Hot wind standard type F series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Series division power supply Heater capacity Power consumption (50 / 60Hz) Current value (50 / 60Hz) Temperature adjustment method electronic control P.I.D Control method Non -contact SSC type Wind volume adjustment manual damper method Temperature adjustment range including heat circulation One -way discharge maximum temperature (Note 1) Types and capacity (50 / 60Hz) Mobile volume (50 / 60Hz) Static pressure (50 / 60Hz) External dimensions (hot air outlet / suction port) Compatible duct diameter (hot air outlet / suction port) Inspitable maximum allowable temperature (when using circulation) External dimensions (width W x depth D x height H) mass Installation conditions installation location Installation conditions ground Leakage breaker Temperature and humidity of the surrounding environment Power cord condition
Hot wind standard type F series-Part Number-SHD-1.3FⅡ

SHD-1.3FⅡ

Available upon quote

FⅡ series

100V

1.3kw

1.4 / 1.4kw

13.5 / 13.6a

Room temperature -350 ° C

200 ° C

1φ100 (45 / 66W)

1.7 / 2.1㎥ / min

333 / 480pa

φ48mm / φ73mm

φ50mm / φ75mm

200 ° C

W524 x D344 x H469mm

26kg

Horizontal installation indoors that are not exposed to rain and wind

Installation (D type)

Sensitive current 100mA or more 20A type

0-40 ° C / 80 % RH or less

VCT2.0 square Mirimeter x 3 core

Hot wind standard type F series-Part Number-SHD-2FⅡ

SHD-2FⅡ

Available upon quote

FⅡ series

Single phase 200V

2kw

2.1 / 2.1kw

10.2 / 10.3A

Room temperature -350 ° C

200 ° C

1φ200 (47 / 60W)

1.7 / 2.1㎥ / min

333 / 480pa

φ48mm / φ73mm

φ50mm / φ75mm

200 ° C

W524 x D344 x H469mm

26kg

Horizontal installation indoors that are not exposed to rain and wind

Installation (D type)

Sensitive current 100ma or more 15A type

0-40 ° C / 80 % RH or less

VCT2.0 square Mirimeter x 3 core

Hot wind standard type F series-Part Number-SHD-4FⅡ

SHD-4FⅡ

Available upon quote

FⅡ series

3 phase 200V

4kw

4.1 / 4.2kw

12.2 / 12.3A

Room temperature -350 ° C

300 ° C

1φ200 (110 / 155W)

3.7 / 4.3㎥ / min

627 / 882Pa

φ73mm / φ98mm

φ75mm / φ100mm

200 ° C

W578 × D359 × H522mm

33kg

Horizontal installation indoors that are not exposed to rain and wind

Installation (D type)

Sensitive current 100ma or more 15A type

0-40 ° C / 80 % RH or less

VCT2.0 Square Mirimeter x 4 core

Hot wind standard type F series-Part Number-SHD-6FⅡ

SHD-6FⅡ

Available upon quote

FⅡ series

3 phase 200V

6kw

6.1 / 6.2kw

18.0 / 18.1a

Room temperature -350 ° C

350 ℃

1φ200 (110 / 155W)

3.7 / 4.3㎥ / min

627 / 882Pa

φ73mm / φ98mm

φ75mm / φ100mm

200 ° C

W578 × D359 × H522mm

33kg

Horizontal installation indoors that are not exposed to rain and wind

Installation (D type)

Sensitive current 100mA or more 20A type

0-40 ° C / 80 % RH or less

VCT3.5 square Mirimeter x 4 core

Hot wind standard type F series-Part Number-SHD-9FⅡ

SHD-9FⅡ

Available upon quote

FⅡ series

3 phase 200V

9kw

9.1 / 9.2kw

26.9 / 27.2a

Room temperature -350 ° C

350 ℃

1φ200 (150 / 230W)

5.0 / 6.0㎥ / min

725 / 1068Pa

φ98mm / φ98mm

φ100mm / φ100mm

200 ° C

W612 x D364 x H522mm

35kg

Horizontal installation indoors that are not exposed to rain and wind

Installation (D type)

Sensitive current 100mA or more 30A type

0-40 ° C / 80 % RH or less

VCT5.5 Square Mirimeter x 4 core

Hot wind standard type F series-Part Number-SHD-15FⅢ

SHD-15FⅢ

Available upon quote

FⅡ series

3 phase 200V

15kW

15.4 / 15.6kw

45.0 / 45.3A

Room temperature -350 ° C

350 ℃

3φ200 (330 / 440W)

8.0 / 9.0㎥ / min

1150 / 1650pa

φ98mm / φ98mm

φ100mm / φ100mm

200 ° C

W922 × D418 × H545mm

58kg

Horizontal installation indoors that are not exposed to rain and wind

Installation (D type)

Sensitive current 100mA or more 60A type

0-40 ° C / 80 % RH or less

VCT14 Square Mirimeter x 4 core

Click on the part number for more information about each product

Other products of Suiden Co.,Ltd.

Reviews shown here are reviews of companies.


View more products of Suiden Co.,Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

18.8hrs

Company Overview

Suiden Co. Ltd, established in 1961 at Osaka, Japan is a manufacturer of industrial air conditioning equipment...

See More