Infrared thermal camera for traffic monitoring FC T2-SeriesHandling Company
Frier Systems Japan Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Requirements | Impact | Consumption | Vibration | Shipping size (sensor/packaging) (L×W×H) | Protection | Storage temperature range | Operating temperature range | Video output | Sensor weight | Sensor dimensions (L×W×H) | Imaging and Lens Viewing Angle | Imaging and Lens Automatic Heater | Imaging and lenses Optimizing image uniformity | Imaging and lenses Image processing | Imaging and Lens Focus | Imaging and Lens Temperature Resolution | Imaging and Lens Detector Type | Imaging and lens sensor resolution | Imaging and lens spectral range | Imaging and Lens Camera Frequency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FLIR FC317 T2, 320 x 240, 17° FOV |
Available upon quote |
90~240VAC, single phase 50~60Hz |
Mil-Std-810F |
5.5 W nominal at 110 VAC, 23 W peak with heater |
IEC 60068-2-27 |
366x188x178mm |
IP66 + IP67 (IEC 60529) |
–55℃~+85℃ |
-50℃~75℃ (Cold start: -40℃~70℃) |
NTSC, analog |
Without sunshade 1.8 kg With sunshade 2.2 kg |
Without sunshade 259 x 114 x 106 mm With sunshade 282 x 129 x 115 mm |
17° x 13° |
Removes up to 4mm of ice from windows Automatic de-icing, tested according to MIL-STD-810F method 521.1 |
Auto flat field correction (FFC) |
Auto Gain Control (AGC), Digital Detail Enhancement (DDE) |
Focus free, athermal lens |
<50 mK at f/1.0 |
Focal Plane Array (FPA), uncooled microbolometer VOx |
320x240 |
7.5 ~ 13.5μm |
NTSC: 30Hz |
|
FLIR FC324 T2, 320 x 240, 24° FOV |
Available upon quote |
90~240VAC, single phase 50~60Hz |
Mil-Std-810F |
5.5 W nominal at 110 VAC, 23 W peak with heater |
IEC 60068-2-27 |
366x188x178mm |
IP66 + IP67 (IEC 60529) |
–55℃~+85℃ |
-50℃~75℃ (Cold start: -40℃~70℃) |
NTSC, analog |
Without sunshade 1.8 kg With sunshade 2.2 kg |
Without sunshade 259 x 114 x 106 mm With sunshade 282 x 129 x 115 mm |
24° x 18° |
Removes up to 4mm of ice from windows Automatic de-icing, tested according to MIL-STD-810F method 521.1 |
Auto flat field correction (FFC) |
Auto Gain Control (AGC), Digital Detail Enhancement (DDE) |
Focus free, athermal lens |
<50 mK at f/1.0 |
Focal Plane Array (FPA), Uncooled Vanadium Oxide (Vox) Microbolometer |
320x240 |
7.5 ~ 13.5μm |
NTSC: 30Hz |
|
FLIR FC332 T2, 320x240, 32° FOV |
Available upon quote |
90~240VAC, single phase 50~60Hz |
Mil-Std-810F |
5.5 W nominal at 110 VAC, 23 W peak with heater |
IEC 60068-2-27 |
366x188x178mm |
IP66 + IP67 (IEC 60529) |
–55℃~+85℃ |
Focus free, athermal lens |
NTSC, analog |
Without sunshade 1.8 kg With sunshade 2.2 kg |
Without sunshade 259 x 114 x 106 mm With sunshade 282 x 129 x 115 mm |
32° x 26° |
Removes up to 4mm of ice from windows Automatic de-icing, tested according to MIL-STD-810F method 521.1 |
Auto flat field correction (FFC) |
Auto Gain Control (AGC), Digital Detail Enhancement (DDE) |
Focus free, athermal lens |
<50 mK at f/1.0 |
Focal Plane Array (FPA), Uncooled Vanadium Oxide (Vox) Microbolometer |
320x240 |
7.5 ~ 13.5μm |
NTSC: 30Hz |
|
FLIR FC344 T2, 320x240, 44° FOV |
Available upon quote |
90~240VAC, single phase 50~60Hz |
Mil-Std-810F |
5.5 W nominal at 110 VAC, 23 W peak with heater |
IEC 60068-2-27 |
366x188x178mm |
IP66 + IP67 (IEC 60529) |
–55℃~+85℃ |
-50℃~75℃ (Cold start: -40℃~70℃) |
NTSC, analog |
Without sunshade 1.8 kg With sunshade 2.2 kg |
Without sunshade 259 x 114 x 106 mm With sunshade 282 x 129 x 115 mm |
44° x 36° |
Removes up to 4mm of ice from windows Automatic de-icing, tested according to MIL-STD-810F method 521.1 |
Auto flat field correction (FFC) |
Auto Gain Control (AGC), Digital Detail Enhancement (DDE) |
Focus free, athermal lens |
<50 mK at f/1.0 |
Focal Plane Array (FPA), Uncooled Vanadium Oxide (Vox) Microbolometer |
320x240 |
7.5 ~ 13.5μm |
NTSC: 30Hz |
|
FLIR FC632 T2, 640 x 480, 32° FOV |
Available upon quote |
90~240VAC, single phase 50~60Hz |
Mil-Std-810F |
5.5 W nominal at 110 VAC, 23 W peak with heater |
IEC 60068-2-27 |
366x188x178mm |
IP66 + IP67 (IEC 60529) |
–55℃~+85℃ |
-50℃~75℃ (Cold start: -40℃~70℃) |
NTSC, analog |
Without sunshade 1.8 kg With sunshade 2.2 kg |
Without sunshade 259 x 114 x 106 mm With sunshade 282 x 129 x 115 mm |
32° x 26° |
Removes up to 4mm of ice from windows Automatic de-icing, tested according to MIL-STD-810F method 521.1 |
Auto flat field correction (FFC) |
Auto Gain Control (AGC), Digital Detail Enhancement (DDE) |
Focus free, athermal lens |
<50 mK at f/1.0 |
Focal Plane Array (FPA), uncooled microbolometer VOx |
640x480 |
7.5 ~ 13.5μm |
NTSC: 30Hz |
|
FLIR FC632 T2, 640 x 480, 44° FOV |
Available upon quote |
90~240VAC, single phase 50~60Hz |
Mil-Std-810F |
5.5 W nominal at 110 VAC, 23 W peak with heater |
IEC 60068-2-27 |
366x188x178mm |
IP66 + IP67 (IEC 60529) |
–55℃~+85℃ |
-50℃~75℃ (Cold start: -40℃~70℃) |
NTSC, analog |
Without sunshade 1.8 kg With sunshade 2.2 kg |
Without sunshade 259 x 114 x 106 mm With sunshade 282 x 129 x 115 mm |
44° x 36° |
Removes up to 4mm of ice from windows Automatic de-icing, tested according to MIL-STD-810F method 521.1 |
Auto flat field correction (FFC) |
Auto Gain Control (AGC), Digital Detail Enhancement (DDE) |
Focus free, athermal lens |
<50 mK at f/1.0 |
Focal Plane Array (FPA), uncooled microbolometer VOx |
640x480 |
7.5 ~ 13.5μm |
NTSC: 30Hz |