Product
Micro liquid flowmeter μLF-300S (separate sensor type)Handling Company
Sonic Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Alarm output | Analog output | Applicable fluid temperature range | Attached cable | Contact input | Digital output | Flow range | Fluid kinematic viscosity | Fluid pressure | Integrated pulse output | Key input | Liquid to be measured | Measurement accuracy | Measurement principle | Model | Power consumption | Power supply | Repeatability | Size WxHxD (mm) | Structure | Tube diameter | Tube material | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ΜLF-300S |
Available upon quote | 1ch (open collector) | 4-20mA (instantaneous flow rate), load resistance 500Ω or less |
15℃~80℃ *Please check in advance if using at temperatures above 60℃. |
5m, connector connection | 1ch (zero flow rate setting or integration clear) | 4-wire RS-422, 4-wire RS-485 |
0 ml/min ~ 1,000 ml/min (μLF-300S + μLT-8I) 0 ml/min ~ 1,000 ml/min (μLF-300S + μLT-8I) |
100mm^2/sec or less | 0.5MPa or less | 1ch (open collector) | 4 input buttons |
Pure water, aqueous solutions, various chemical solutions *Please check in advance if using liquids other than water. |
±0.5%RD (1/8 inch : 200 ~ 1,000ml/min Conditions: room temperature, constant temperature water) ±1ml/min (1/8 inch : 0 ~ 199ml/min) |
Ultrasonic propagation time difference method | ΜLF-300S + μLT-8I (1/8 inch) or μLF-300S + μLT-4I (1/4 inch) | 3.6W or less | DC 24V ±10% | ±0.2% (pure, liquid temperature ±0.5℃, 30 seconds average value) |
Transducer 97 x 49 x 127 Detection part 90 x 25 x 20 (excluding tube) |
IP65 equivalent | 1/8 inch OD: 3.17mm, ID: 2.17mm, 1/4 inch OD: 6.35mm, ID: 4.35mm | PFA (fluororesin) | Converter 240g, Detector 70g |