All Categories

History

PH/ORP controller that can measure pH/ORP values ​​and transmit output-PE-11N
PH/ORP controller that can measure pH/ORP values ​​and transmit output-PE-51
PH/ORP controller that can measure pH/ORP values ​​and transmit output-PE-61
PH/ORP controller that can measure pH/ORP values ​​and transmit output-Cem Corporation Co., Ltd.

PH/ORP controller that can measure pH/ORP values ​​and transmit output
Cem Corporation Co., Ltd.

Cem Corporation Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

16.9hours

Relatively Fast Response


About This Product

Capable of measuring pH/ORP values ​​and transmitting output

  • Product

    PH/ORP controller that can measure pH/ORP values ​​and transmit output

Share this product


370+ people viewing

Last viewed: 2 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

3 Models of PH/ORP controller that can measure pH/ORP values ​​and transmit output

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Power supply Weight Alarm output Display Automatic calibration Measuring range Temperature compensation element Temperature compensation Power consumption Standard accessories Manual calibration Size Operating environment Control method Control output Control input Resolution Protective structure Transmission output Error display PH calibration
PH/ORP controller that can measure pH/ORP values ​​and transmit output-Part Number-PE-11N

PE-11N

Available upon quote

AC100~240V free power supply

Approximately 2kg

-

LCD (with backlight)

With automatic calibration liquid judgment function
pH6.86 and one of pH4.01, 9.18, 1.68 (JIS)
One of pH7.00, 4.00, and 10.00 (USA)

PH: 0.00~14.00 ORP: -999~+999mV Temperature: 0~100℃

6.8kΩ・500Ω・Pt1000Ω

PH automatic temperature compensation Temperature compensation range: 0~60℃

10VA (at no load)

Sunshade cover

PH6.86, 7.00 and liquids that are more than 2pH apart

138 (W) × 138 (H) × 175 (D) mm

-

ON/OFF control, time division proportional control, twin timer control, zone alarm, ON/OFF relay output

2 points of control, no-voltage contact output, maximum resistance load capacity AC250V3A
1 zone alarm, no-voltage contact output maximum load capacity AC250V3A

Output P1, P2 only, 1 external voltage signal (EXT) AC100~240V, 3 external contacts (LC1, 2, 3) No-voltage contact

PH: 0.01pH ORP: 1mV

Drip-proof structure equivalent to IP54 (when using sunshade cover)

DC4~20mA (maximum load resistance 500Ω) *Error current setting possible

- -
PH/ORP controller that can measure pH/ORP values ​​and transmit output-Part Number-PE-51

PE-51

Available upon quote

DC24V±5%

Approximately 1.0kg

-

Digital LCD (with backlight)

-

PH: 0.00~14.00 ORP: -999~+999mV
Temperature: 0~100℃ (when using high temperature temperature compensation electrode)

6.8kΩ・500Ω・Pt1000Ω

PH automatic temperature compensation Temperature compensation range 0~100℃ (0~60℃ at 6.8k)

4VA

Sunshade cover

-

138 (W) × 138 (H) × 17 4 (D) mm

0~45℃ 85%RH or less

- - -

PH: 0.01pH ORP: 1mV

Drip-proof structure equivalent to IP54 (when using sunshade cover)

DC4~20mA Input/output isolation Maximum connected load resistance 500Ω

PH over, Temp abnormality, error current setting possible

With automatic calibration liquid judgment function
pH6.86 and one of pH4.01, 9.18, 1.68 (JIS)
One of pH7.00, 4.00, and 10.00 (USA)

PH/ORP controller that can measure pH/ORP values ​​and transmit output-Part Number-PE-61

PE-61

Available upon quote

AC100~240V 50/60Hz

Approximately 1.5kg

1A contact output 1 point Contact capacity: AC250V 3A max A (Alarm) Zone alarm

Digital LCD (with backlight) Graphic type
Items: Setting value, output status, external signal input status

With automatic calibration liquid judgment function
pH6.86 and one of pH4.01, 9.18, 1.68 (JIS)
One of pH7.00, 4.00, and 10.00 (USA)

PH: 0.00~14.00 ORP: -999~+999mV
Temperature: 0~100℃ (when using high temperature temperature compensation electrode)

6.8kΩ, 1,000Ω, 500Ω

Automatic temperature compensation Temperature compensation range: 0~100℃ (0~60℃ at 6.8k)

Approximately 10 VA

Sunshade cover

PH6.86, 7.00 and liquids that are more than 2pH apart

138 (W) × 138 (H) × 175 (D) mm

0~45℃ 85%RH or less

Pulse proportional operation: SET 0~14.00pH: (-999~+999mV)
PB 0~14.00pH: (-999~+999mV)
Pulse number variable 5~350 pulses
Twin timer operation: ON/OFF time ON...0~599 seconds, OFF...1~599 seconds
Manual: Manual operation via display screen

Contact output for pulse pump 2 points (semiconductor relay contact) 350 pulses MAX/min
P1, P2 pH (ORP) control contact output (P1, P2 can be linked with external signals)
Contact capacity: DC48V 0.1A max

No-voltage contact signal 3 points
Voltage signal 1 point (AC100~240V)
HOLD signal (no voltage contact)

PH: 0.01pH ORP: 1mV

Drip-proof structure equivalent to IP54 (when using sunshade cover)

DC4~20mA Input/output isolation Maximum connected load resistance 500Ω

- -

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More pH Meters Products

Other products of Cem Corporation Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Cem Corporation Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

16.9hrs


Company Review

5.0
  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree