All Categories
History
Relatively Fast Response
Product
Air management hubHandling Company
Nippon Dick Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Fluid measurement fluid | Electrical power supply voltage | Electrical specification protection | Electrical specification current consumption | Electrical indicator | Environmental use temperature range | Environmental preservation temperature range | Environmental protection structure | Environmental and humidity | Environmental altitude | Environmental pollution | Environmental installation location | Flow rate specification rated rated flow rate range | Flow -up specification specification flow rate range | Flow -up specification settings minimum unit instantaneous flow rate | Flow -up specification setting settings minimum unit accumulation flow rate | Flow rate specification accuracy | Flow -up specification repetition accuracy | Flow -up specification pressure characteristics | Flow -up specification temperature characteristic | Flow rate specification unit | Pressure specification rated pressure range | Pressure specification pressure -bearing pressure | Pressure specification accuracy | Pressure specification repetition accuracy | Pressure specification temperature characteristics | Pressure specification unit | Temperature specification rated temperature range | Temperature specification accuracy | Input / output user setting Port Number of empty ports | Input/Output User configurable ports Number of free ports | Pressure specifications Unit | Pressure specifications Rated pressure range | Pressure specifications Temperature characteristics | Pressure specifications accuracy | Pressure specifications Repeatability | Pressure specifications | Fluid fluid temperature | Fluid Measuring fluid | Flow specification unit | Flow rate specifications Pressure characteristics | Flow specification Rated flow range | Flow rate specifications Temperature characteristics | Flow rate specifications Accumulated flow range | Flow rate specifications Accuracy | Flow rate specifications Repeatability | Flow rate specifications Minimum setting unit Instantaneous flow rate | Flow rate specifications Minimum setting unit Total flow rate | Temperature specification unit | Temperature specifications Rated temperature range | Temperature specifications Accuracy | Environment Operating temperature range | Environment Storage temperature range | Environment protection structure | Environment Ambient humidity | Environment pollution degree | Environmental standards | Environment Installation location | Environment altitude | Electrical specifications indicator | Electrical specifications protection | Electrical specifications Current consumption | Electrical specifications Power supply voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
EXA1-20 |
Available upon quote |
air |
DC24V ± 10 % |
Reverse connection protection, overcurrent protection |
400ma |
LED & LCD |
0 to 50 ° C (freezing and without condensation) |
-10 to 60 ° C (freezing and without condensation) |
IP65 (only for electrical equipment) complies with IEC60529 |
35-85 % RH |
Up to 3,000m |
3 |
Outdoors |
5 ~ 500L/min |
0 ~ 9,999,999,990L |
1L/min |
10L |
± 3.0 % F.S. |
± 1.0 % F.S. |
± 5.0 % F.S. |
± 5.0 % F.S. (0 to 50 ° C, 25 ° C standard) |
L/Min, CFM (FT3/Min) |
0 ~ 1.0MPa |
1.5MPA |
± 3.0 % F.S. |
± 1.0 % F.S. |
± 5.0 % F.S. (0 to 50 ° C, 25 ° C standard) |
MPA, KPA, KGF/CM2, Bar, PSI |
0 to 50 ℃ |
± 2.5 ℃ (flow range 10 % to 100 %) |
1 |
1 |
MPa, kPa, kgf/cm2, bar, psi |
0~1.0MPa |
±5.0%F.S. (0~50℃, 25℃ standard) |
±3.0%F.S. |
±1.0%F.S. |
1.5MPa |
0~50℃ |
air |
L/min, CFM (ft3/min) |
±5.0%F.S. (0~1.0MPa 0.5MPa standard) |
5~500L/min |
±5.0%F.S. (0~50℃, 25℃ standard) |
0~9,999,999,990L |
±3.0%F.S. |
±1.0%F.S. |
1L/min |
10L |
℃, ℉ |
0~50℃ |
±2.5℃ (Flow rate range 10%~100%) |
0~50℃ (No freezing or condensation) |
-10~60℃ (No freezing or condensation) |
IP65 (electrical equipment only) Compliant with IEC60529 |
35~85%RH |
3 |
CE/UKCA marking, UL (CSA) |
outdoor |
Up to 3,000m |
LED&LCD |
Reverse connection protection, overcurrent protection |
400mA |
DC24V±10% |
![]() |
EXA1-30 |
Available upon quote |
air |
DC24V ± 10 % |
Reverse connection protection, overcurrent protection |
400ma |
LED & LCD |
0 to 50 ° C (freezing and without condensation) |
-10 to 60 ° C (freezing and without condensation) |
IP65 (only for electrical equipment) complies with IEC60529 |
35-85 % RH |
Up to 3,000m |
3 |
Outdoors |
10 ~ 1,000L/min |
0 ~ 9,999,999,990L |
1L/min |
10L |
± 3.0 % F.S. |
± 1.0 % F.S. |
± 5.0 % F.S. |
± 5.0 % F.S. (0 to 50 ° C, 25 ° C standard) |
L/Min, CFM (FT3/Min) |
0 ~ 1.0MPa |
1.5MPA |
± 3.0 % F.S. |
± 1.0 % F.S. |
± 5.0 % F.S. (0 to 50 ° C, 25 ° C standard) |
MPA, KPA, KGF/CM2, Bar, PSI |
0 to 50 ℃ |
± 2.5 ℃ (flow range 10 % to 100 %) |
1 |
1 |
MPa, kPa, kgf/cm2, bar, psi |
0~1.0MPa |
±5.0%F.S. (0~50℃, 25℃ standard) |
±3.0%F.S. |
±1.0%F.S. |
1.5MPa |
0~50℃ |
air |
L/min, CFM (ft3/min) |
±5.0%F.S. (0~1.0MPa 0.5MPa standard) |
10~1,000L/min |
±5.0%F.S. (0~50℃, 25℃ standard) |
0~9,999,999,990L |
±3.0%F.S. |
±1.0%F.S. |
1L/min |
10L |
℃, ℉ |
0~50℃ |
±2.5℃ (Flow rate range 10%~100%) |
0~50℃ (No freezing or condensation) |
-10~60℃ (No freezing or condensation) |
IP65 (electrical equipment only) Compliant with IEC60529 |
35~85%RH |
3 |
CE/UKCA marking, UL (CSA) |
outdoor |
Up to 3,000m |
LED&LCD |
Reverse connection protection, overcurrent protection |
400mA |
DC24V±10% |
![]() |
EXA1-40 |
Available upon quote |
air |
DC24V ± 10 % |
Reverse connection protection, overcurrent protection |
400ma |
LED & LCD |
0 to 50 ° C (freezing and without condensation) |
-10 to 60 ° C (freezing and without condensation) |
IP65 (only for electrical equipment) complies with IEC60529 |
35-85 % RH |
Up to 3,000m |
3 |
Outdoors |
20 ~ 2,000L/min |
0 ~ 9,999,999,990L |
2L/min |
10L |
± 3.0 % F.S. |
± 1.0 % F.S. |
± 5.0 % F.S. |
± 5.0 % F.S. (0 to 50 ° C, 25 ° C standard) |
L/Min, CFM (FT3/Min) |
0 ~ 1.0MPa |
1.5MPA |
± 3.0 % F.S. |
± 1.0 % F.S. |
± 5.0 % F.S. (0 to 50 ° C, 25 ° C standard) |
MPA, KPA, KGF/CM2, Bar, PSI |
0 to 50 ℃ |
± 2.5 ℃ (flow range 10 % to 100 %) |
1 |
1 |
MPa, kPa, kgf/cm2, bar, psi |
0~1.0MPa |
±5.0%F.S. (0~50℃, 25℃ standard) |
±3.0%F.S. |
±1.0%F.S. |
1.5MPa |
0~50℃ |
air |
L/min, CFM (ft3/min) |
±5.0%F.S. (0~1.0MPa 0.5MPa standard) |
20~2,000L/min |
±5.0%F.S. (0~50℃, 25℃ standard) |
0~9,999,999,990L |
±3.0%F.S. |
±1.0%F.S. |
2L/min |
10L |
℃, ℉ |
0~50℃ |
±2.5℃ (Flow rate range 10%~100%) |
0~50℃ (No freezing or condensation) |
-10~60℃ (No freezing or condensation) |
IP65 (electrical equipment only) Compliant with IEC60529 |
35~85%RH |
3 |
CE/UKCA marking, UL (CSA) |
outdoor |
Up to 3,000m |
LED&LCD |
Reverse connection protection, overcurrent protection |
400mA |
DC24V±10% |
![]() |
EXA1-60 |
Available upon quote |
air |
DC24V ± 10 % |
Reverse connection protection, overcurrent protection |
400ma |
LED & LCD |
0 to 50 ° C (freezing and without condensation) |
-10 to 60 ° C (freezing and without condensation) |
IP65 (only for electrical equipment) complies with IEC60529 |
35-85 % RH |
Up to 3,000m |
3 |
Outdoors |
40 ~ 4,000L/min |
0 ~ 9,999,999,990L |
2L/min |
10L |
± 3.0 % F.S. |
± 1.0 % F.S. |
± 5.0 % F.S. |
± 5.0 % F.S. (0 to 50 ° C, 25 ° C standard) |
L/Min, CFM (FT3/Min) |
0 ~ 1.0MPa |
1.5MPA |
± 3.0 % F.S. |
± 1.0 % F.S. |
± 5.0 % F.S. (0 to 50 ° C, 25 ° C standard) |
MPA, KPA, KGF/CM2, Bar, PSI |
0 to 50 ℃ |
± 2.5 ℃ (flow range 10 % to 100 %) |
1 |
1 |
MPa, kPa, kgf/cm2, bar, psi |
0~1.0MPa |
±5.0%F.S. (0~50℃, 25℃ standard) |
±3.0%F.S. |
±1.0%F.S. |
1.5MPa |
0~50℃ |
air |
L/min, CFM (ft3/min) |
±5.0%F.S. (0~1.0MPa 0.5MPa standard) |
40~4,000L/min |
±5.0%F.S. (0~50℃, 25℃ standard) |
0~9,999,999,990L |
±3.0%F.S. |
±1.0%F.S. |
2L/min |
10L |
℃, ℉ |
0~50℃ |
±2.5℃ (Flow rate range 10%~100%) |
0~50℃ (No freezing or condensation) |
-10~60℃ (No freezing or condensation) |
IP65 (electrical equipment only) Compliant with IEC60529 |
35~85%RH |
3 |
CE/UKCA marking, UL (CSA) |
outdoor |
Up to 3,000m |
LED&LCD |
Reverse connection protection, overcurrent protection |
400mA |
DC24V±10% |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
14.2hrs
Company Review
5.0