Revolution of membrane thickening measurement, advanced utilities, non -contact film thick meter coat master Flex-Court Master Flex
Revolution of membrane thickening measurement, advanced utilities, non -contact film thick meter coat master Flex-SANKO ELECTRONIC LABORATORY CO.,LTD

Revolution of membrane thickening measurement, advanced utilities, non -contact film thick meter coat master Flex
SANKO ELECTRONIC LABORATORY CO.,LTD

SANKO ELECTRONIC LABORATORY CO.,LTD's Response Status

Response Rate

100.0%

Response Time

12.3hours

Relatively Fast Response


About This Product

Measure the wet / dry coating layer in non -contact. It also supports the measurement of powder paint before and after the curing treatment.

■ Features

・ The coating thickness of the wet / dry state can be measured in non -contact ・ It also supports curved surfaces, corners, edges, etc. ・ The coating thickness on the coarse surface can also be measured ・ Supports the base and coating layers of various materials (eg, metal, resin, wood, CFRP, ceramic, etc.) ・ Measurement in real time can be performed even when the painted line is operating ・ Avoid redoing and turning back, etc. by greatly reducing construction time ・ It can be confirmed immediately after applying, and can reduce the consumption of materials by up to 30%. ・ The measurement time per place is a few seconds, and the measurement area is φ1 to 50mm. ・ The distance from the measured object is 2 to 15 cm, the irradiation angle is ± 35 ° (no right angle is 90 °). ・ Ideal for on -site work with a lightweight / compact weight of about 1.5 kg ・ Wi-Fi connection is required for measurement. Customers will select either an optional data analysis server or a cloud service that can be used for free for 3 years.

■ Use

・ Paint on plastic ・ Zinc flakes coating (low -temperature baking paint) ・ Laser coating on plastic substrate ・ Fiber enhancement cement board ・ Medium density fiber plate (MDF / molded plate made from wood fiber) ・ Powder coating (aluminum coating), etc.

■ Principles

The principle of the coatmaster uses advanced hot light (utilities / ATO). The coating layer (surface) of the sample (the surface) of the sample (the occurrence of infrared rays) is caused by the excitation phenomenon by the optical pulse (visible light / xenon light flash) containing an irradiated infrared. The radiant heat generated at that time is captured by an infrared sensor. Since the frequency differs depending on the unique property of the coating layer, the time (ΔT) of irradiation to radiation (δ T) is measured and performed by performing calculation processing (μm). The thinner the coating layer, the shorter the time from irradiation to radiation, and the thicker the time.

■ Advanced coatmaster

When measuring a coarse surface, the coat master automatically uses the average process to correct the roughness.

■ Applicable field

·Powder coating ・ Industrial coating ・ Sliding coating ·glue ・ Dissolve coating

  • Product

    Revolution of membrane thickening measurement, advanced utilities, non -contact film thick meter coat master Flex

Share this product


300+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Revolution of membrane thickening measurement, advanced utilities, non -contact film thick meter coat master Flex

Image Part Number Price (excluding tax) Storage environment Measurement angle Measurement time Operating environment temperature Operating environment humidity power supply Range of measurement distance Measurement interval size IP grade Measurement of mobile body Measurement range Measured number Measurement point size standard deviation weight
Revolution of membrane thickening measurement, advanced utilities, non -contact film thick meter coat master Flex-Part Number-Court Master Flex

Court Master Flex

Available upon quote

-10 to 50 ° C, maximum humidity: 80% (without condensation)

± 35 °

0.25 seconds (depending on the thickness of the coating)

0 to 35 ℃

10 to 75 %

18VDC LI -Ion Battery Pack

20-150mm

2 seconds

374 x 91 x 203mm

IP50

Possible (depending on the movement speed)

Painting after drying: 1-1,000 μm, drying pre-paint: 1-400 μm (depending on the coating status)

Up to 800 times

2mm^2 at 75mm measured distance

Standard

Approximately 1.3kg

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Film Thickness Meters Products

Other products of SANKO ELECTRONIC LABORATORY CO.,LTD

Reviews shown here are reviews of companies.


View more products of SANKO ELECTRONIC LABORATORY CO.,LTD

About Company Handling This Product

Response Rate

100.0%


Response Time

12.3hrs

Company Overview

SANKO ELECTRONIC LABORATORY CO.,LTD, established on August 1, 1963, and based in Kawasaki, Kanagawa, is a manu...

See More

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree