TILTIX inclination ACS-◯◯◯ -M100-ACS-360-1-M100-VK2-PM
TILTIX inclination ACS-◯◯◯ -M100-ACS-360-1-M100-VK2-PN
TILTIX inclination ACS-◯◯◯ -M100-ACS-360-1-M100-VE2-PM
TILTIX inclination ACS-◯◯◯ -M100-POSITAL -Fraba

TILTIX inclination ACS-◯◯◯ -M100
POSITAL -Fraba


About This Product

◾️The precise and robust tilt sensor The inclination is also called a tilt sensor and is designed to measure the angle of the object against gravity. This inclination measures the direction of the angle in a space based on gravity and outputs the value via an electric interface. The inclination does not require a mechanical link other than installation, so it is easy to incorporate into the application and is a great advantage for the designer. Posital's inclined portfolio provides solutions in various industries to work on applications peculiar to applications. It is a dynamic inclination that outputs a clean measurement signal that can be used with confidence in a mobile, shock, or vibration, such as cranes, construction machinery, mining machinery, and agricultural machinery. ◾️ Installation and installation The inclined meter must be installed horizontally when measuring the inclined angle of the two axis, and when measuring one axis, differs depending on the application and machine. ◾️ Application The inclination is a great advantage for the designer because it does not require a mechanical link mechanism, but can easily and efficiently monitor spatial directions.

  • Product

    TILTIX inclination ACS-◯◯◯ -M100




*Please note that we may not be able to accommodate sample requests.

6 Models of TILTIX inclination ACS-◯◯◯ -M100

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Connection type Connector 1 Connector 2 Current consumption current Default node ID EMC: Noise Immediate Electromagnetic interference Filling material Housing material Impact resistance Measurement range Mttf Operating temperature Output driver Over -voltage prevention Polar Improvement Protective structure Setting time Supply voltage Temperature gradient Vibration resistance accuracy application interface resolution storage temperature weight
TILTIX inclination ACS-◯◯◯ -M100-Part Number-ACS-360-1-M100-VK2-PM

ACS-360-1-M100-VK2-PM

Available upon quote Connector M12 M12 male connector (5 pins, A code) - ≤ 100 ma @5V, ≤ 45 ma @10V, ≤ 25 ma @24V 127D Din en 61000-6-2 Din en 61000-6-4 PUR (polyurethane) Daikast aluminum alloy ≤ 100 g (Half Sign 6 MS, EN 60068-27) 360 ° 450 YEARS @ 40 ℃ -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) Desc Existence Existence IP68/IP69K 320 MS 9 - 30 VDC 0.004 °/ K 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) ± 0.10 ° 1 -axis measurement and vertical measurement MODBUS RTU 0.01 ° -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) 220 g (0.49 LB)
TILTIX inclination ACS-◯◯◯ -M100-Part Number-ACS-360-1-M100-VK2-PN

ACS-360-1-M100-VK2-PN

Available upon quote Connector 2 x M12 (M+F) M12 male connector (5 pins, A code) M12 female connector (5 pins, A code) ≤ 100 ma @5V, ≤ 45 ma @10V, ≤ 25 ma @24V 127D Din en 61000-6-2 Din en 61000-6-4 PUR (polyurethane) Daikast aluminum alloy ≤ 100 g (Half Sign 6 MS, EN 60068-27) 360 ° 450 YEARS @ 40 ℃ -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) Desc Existence Existence IP68/IP69K 320 MS 9 - 30 VDC 0.004 °/ K 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) ± 0.10 ° 1 -axis measurement and vertical measurement MODBUS RTU 0.01 ° -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) 220 g (0.49 LB)
TILTIX inclination ACS-◯◯◯ -M100-Part Number-ACS-360-1-M100-VE2-PM

ACS-360-1-M100-VE2-PM

Available upon quote Connector M12 M12 male connector (5 pins, A code) - ≤ 100 ma @5V, ≤ 45 ma @10V, ≤ 25 ma @24V 127D Din en 61000-6-2 Din en 61000-6-4 PUR (polyurethane) Fiber Enhancement PBT (Polybchiren Televaltarate) ≤ 100 g (Half Sign 6 MS, EN 60068-27) 360 ° 450 YEARS @ 40 ℃ -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) Desc Existence Existence IP66/IP67 320 MS 9 - 30 VDC 0.004 °/ K 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) ± 0.10 ° 1 -axis measurement and vertical measurement MODBUS RTU 0.01 ° -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) 100 g (0.22 LB)
TILTIX inclination ACS-◯◯◯ -M100-Part Number-ACS-080-2-M100-HE2-PM

ACS-080-2-M100-HE2-PM

Available upon quote Connector M12 M12 male connector (5 pins, A code) - ≤ 100 ma @5V, ≤ 45 ma @10V, ≤ 25 ma @24V 127D Din en 61000-6-2 Din en 61000-6-4 PUR (polyurethane) Fiber Enhancement PBT (Polybchiren Televaltarate) ≤ 100 g (Half Sign 6 MS, EN 60068-27) ± 80 ° 450 YEARS @ 40 ℃ -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) Desc Existence Existence IP66/IP67 320 MS 9 - 30 VDC 0.004 °/ K 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) ± 0.10 ° (within +/- 60 ° range) 2 axis measurement and horizontal measurement MODBUS RTU 0.01 ° -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) 100 g (0.22 LB)
TILTIX inclination ACS-◯◯◯ -M100-Part Number-ACS-080-2-M100-HK2-PN

ACS-080-2-M100-HK2-PN

Available upon quote Connector 2 x M12 (M+F) M12 male connector (5 pins, A code) M12 female connector (5 pins, A code) ≤ 100 ma @5V, ≤ 45 ma @10V, ≤ 25 ma @24V 127D Din en 61000-6-2 Din en 61000-6-4 PUR (polyurethane) Daikast aluminum alloy ≤ 100 g (Half Sign 6 MS, EN 60068-27) ± 80 ° 450 YEARS @ 40 ℃ -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) Desc Existence Existence IP68/IP69K 320 MS 9 - 30 VDC 0.004 °/ K 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) ± 0.10 ° (within +/- 60 ° range) 2 axis measurement and horizontal measurement MODBUS RTU 0.01 ° -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) 220 g (0.49 LB)
TILTIX inclination ACS-◯◯◯ -M100-Part Number-ACS-080-2-M100-HK2-PM

ACS-080-2-M100-HK2-PM

Available upon quote Connector M12 M12 male connector (5 pins, A code) - ≤ 100 ma @5V, ≤ 45 ma @10V, ≤ 25 ma @24V 127D Din en 61000-6-2 Din en 61000-6-4 PUR (polyurethane) Daikast aluminum alloy ≤ 100 g (Half Sign 6 MS, EN 60068-27) ± 80 ° 450 YEARS @ 40 ℃ -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) Desc Existence Existence IP68/IP69K 320 MS 9 - 30 VDC 0.004 °/ K 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) ± 0.10 ° (within +/- 60 ° range) 2 axis measurement and horizontal measurement MODBUS RTU 0.01 ° -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) 220 g (0.49 LB)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of POSITAL -Fraba


View more products of POSITAL -Fraba

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree