Product Image | Part Number | Price (excluding tax) | Connection type | Connector 1 | Connector 2 | Current consumption current | Default node ID | Default transmission speed | EMC: Noise Immediate | Electromagnetic interference | Filling material | Housing material | Impact resistance | Measurement range | Mttf | Operating temperature | Output driver | Over -voltage prevention | Polar Improvement | Protective structure | Raw material / type | Setting time | Supply voltage | Temperature gradient | Transmission speed | Vibration resistance | accuracy | application | interface | resolution | storage temperature | weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ACS-080-2-C902-HK2-PN |
Available upon quote | Connector 2 x M12 (M+F) | M12 male connector (5 pins, A code) | M12 female connector (5 pins, A code) | ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC | C0H | 250 k bore rate | Din en 61000-6-2 | Din en 61000-6-4 | PUR (polyurethane) | Daikast aluminum alloy | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ± 80 ° | 350 YEARS @ 40 ℃ | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | Desc | Existence | Existence | IP68/IP69K | - | 150 MS | 10 - 30 VDC | 0.004 °/ K | 125K boretto, 250K bore rate, 500k bore rate | 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) | ± 0.10 ° (within +/- 60 ° range) | 2 axis measurement and horizontal measurement | J1939 | 0.01 ° | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | 220 g (0.49 LB) | |
ACS-080-2-C902-HE2-2W |
Available upon quote | Cable 2 m | Cable 2 m | - | ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC | C0H | 250 k bore rate | Din en 61000-6-2 | Din en 61000-6-4 | PUR (polyurethane) | Fiber Enhancement PBT (Polybchiren Televaltarate) | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ± 80 ° | 350 YEARS @ 40 ℃ | -30 ℃ Fixed (-22 ° f), -5 ° C Flexible (+23 ° F) -+80 ° C (+176 ° F) | Desc | Existence | Existence | IP66/IP67 | PVC | 150 MS | 10 - 30 VDC | 0.004 °/ K | 125K boretto, 250K bore rate, 500k bore rate | 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) | ± 0.10 ° (within +/- 60 ° range) | 2 axis measurement and horizontal measurement | J1939 | 0.01 ° | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | 240 g (0.53 LB) | |
ACS-080-2-C902-HE2-CW |
Available upon quote | Cable 1 m | - | - | ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC | C0H | 250 k bore rate | Din en 61000-6-2 | Din en 61000-6-4 | PUR (polyurethane) | Fiber Enhancement PBT (Polybchiren Televaltarate) | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ± 80 ° | 350 YEARS @ 40 ℃ | -30 ℃ Fixed (-22 ° f), -5 ° C Flexible (+23 ° F) -+80 ° C (+176 ° F) | Desc | Existence | Existence | IP66/IP67 | PVC | 150 MS | 10 - 30 VDC | 0.004 °/ K | 125K boretto, 250K bore rate, 500k bore rate | 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) | ± 0.10 ° (within +/- 60 ° range) | 2 axis measurement and horizontal measurement | J1939 | 0.01 ° | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | 170 g (0.37 LB) | |
ACS-080-2-C902-HK2-CW |
Available upon quote | Cable 1 m | - | - | ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC | C0H | 250 k bore rate | Din en 61000-6-2 | Din en 61000-6-4 | PUR (polyurethane) | Daikast aluminum alloy | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ± 80 ° | 350 YEARS @ 40 ℃ | -40 ° C (-40 ° f) -+80 ° C (+176 ° F) | Desc | Existence | Existence | IP68/IP69K | PUR / PU | 150 MS | 10 - 30 VDC | 0.004 °/ K | 125K boretto, 250K bore rate, 500k bore rate | 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) | ± 0.10 ° (within +/- 60 ° range) | 2 axis measurement and horizontal measurement | J1939 | 0.01 ° | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | 370 g (0.82 LB) | |
ACS-080-2-C902-HK2-2w |
Available upon quote | Cable 2 m | Cable 2 m | - | ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC | C0H | 250 k bore rate | Din en 61000-6-2 | Din en 61000-6-4 | PUR (polyurethane) | Daikast aluminum alloy | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ± 80 ° | 350 YEARS @ 40 ℃ | -40 ° C (-40 ° f) -+80 ° C (+176 ° F) | Desc | Existence | Existence | IP68/IP69K | PUR / PU | 150 MS | 10 - 30 VDC | 0.004 °/ K | 125K boretto, 250K bore rate, 500k bore rate | 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) | ± 0.10 ° (within +/- 60 ° range) | 2 axis measurement and horizontal measurement | J1939 | 0.01 ° | -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) | 520 g (1.15 LB) | |
ACS-080-2-C902-HK2-PM |
Available upon quote | Connector M12 | M12 male connector (5 pins, A code) | - | ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC | C0H | 250 k bore rate | Din en 61000-6-2 | Din en 61000-6-4 | PUR (polyurethane) | Daikast aluminum alloy | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ± 80 ° | 350 YEARS @ 40 ℃ | -40 ° C (-40 ° f)-+85 ° C (+185 ° F) | Desc | Existence | Existence | IP68/IP69K | - | 150 MS | 10 - 30 VDC | 0.004 °/ K | 125K boretto, 250K bore rate, 500k bore rate | 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) | ± 0.10 ° (within +/- 60 ° range) | 2 axis measurement and horizontal measurement | J1939 | 0.01 ° | -40 ° C (-40 ° f)-+85 ° C (+185 ° F) | 220 g (0.49 LB) | |
ACS-080-2-C902-HE2-PM |
Available upon quote | Connector M12 | M12 male connector (5 pins, A code) | - | ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC | C0H | 250 k bore rate | Din en 61000-6-2 | Din en 61000-6-4 | PUR (polyurethane) | Fiber Enhancement PBT (Polybchiren Televaltarate) | ≤ 100 g (Half Sign 6 MS, EN 60068-27) | ± 80 ° | 350 YEARS @ 40 ℃ | -40 ° C (-40 ° f)-+85 ° C (+185 ° F) | Desc | Existence | Existence | IP66/IP67 | - | 150 MS | 10 - 30 VDC | 0.004 °/ K | 125K boretto, 250K bore rate, 500k bore rate | 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) | ± 0.10 ° (within +/- 60 ° range) | 2 axis measurement and horizontal measurement | J1939 | 0.01 ° | -40 ° C (-40 ° f)-+85 ° C (+185 ° F) | 100 g (0.22 LB) |