TILTIX tilted meter ACS-◯◯◯ -CA01-ACS-360-1-CA01-VK3-AW
TILTIX tilted meter ACS-◯◯◯ -CA01-ACS-180-F-CA01-VK3-PW
TILTIX tilted meter ACS-◯◯◯ -CA01-ACS-360-1-CA01-VE3-2W
TILTIX tilted meter ACS-◯◯◯ -CA01-POSITAL -Fraba

TILTIX tilted meter ACS-◯◯◯ -CA01
POSITAL -Fraba


About This Product

◾️The precise and robust tilt sensor The inclination is also called a tilt sensor and is designed to measure the angle of the object against gravity. This inclination measures the direction of the angle in a space based on gravity and outputs the value via an electric interface. The inclination does not require a mechanical link other than installation, so it is easy to incorporate into the application and is a great advantage for the designer. Posital's inclined portfolio provides solutions in various industries to work on applications peculiar to applications. It is a dynamic inclination that outputs a clean measurement signal that can be used with confidence in a mobile, shock, or vibration, such as cranes, construction machinery, mining machinery, and agricultural machinery. ◾️ Installation and installation The inclined meter must be installed horizontally when measuring the inclined angle of the two axis, and when measuring one axis, differs depending on the application and machine. ◾️ Application The inclination is a great advantage for the designer because it does not require a mechanical link mechanism, but can easily and efficiently monitor spatial directions. There are other part numbers.

  • Product

    TILTIX tilted meter ACS-◯◯◯ -CA01

Share this product


530+ people viewing

Last viewed: 18 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of TILTIX tilted meter ACS-◯◯◯ -CA01

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Connection type Current consumption current Default node ID Default transmission speed Device Orientation EMC: Noise Immediate Electromagnetic interference Housing material Impact resistance Measurement range Mttf Operating temperature Output driver Over -voltage prevention Polar Improvement Profile Protective structure Raw material / type Setting time Supply voltage Temperature gradient Transmission speed Vibration resistance Wire cross -sectional area accuracy application cable length interface resolution storage temperature
TILTIX tilted meter ACS-◯◯◯ -CA01-Part Number-ACS-360-1-CA01-VK3-AW

ACS-360-1-CA01-VK3-AW

Available upon quote Cable 10 m ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC 1H 125 k bore rate vertical Din en 61000-6-2 Din en 61000-6-4 Zinc ≤ 100 g (Half Sign 6 MS, EN 60068-27) Max. 360 ° 15.9 years (40 ° C) -40 ° C (-40 ° f) -+80 ° C (+176 ° F) Desc Existence Existence DS-410 IP68/IP69K PUR / PU min 30 ms; Default 200 MS (Dependent On Filter Settings) 10 - 30 VDC 0.004 °/ K Minimum 20 k bore rate, up to 1 m bore rate 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) 0.34 mm² / AWG 22 ± 0.10 ° 1 -axis measurement and vertical measurement 10 m [394 "] Canopen 0.01 ° -40 ° C (-40 ° f)-+85 ° C (+185 ° F)
TILTIX tilted meter ACS-◯◯◯ -CA01-Part Number-ACS-180-E-CA01-HK3-AW

ACS-180-E-CA01-HK3-AW

Available upon quote Cable 10 m ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC 1H 125 k bore rate Horizon Din en 61000-6-2 Din en 61000-6-4 Zinc ≤ 100 g (Half Sign 6 MS, EN 60068-27) Canopen 350 YEARS @ 40 ℃ -40 ° C (-40 ° f) -+80 ° C (+176 ° F) Desc Existence Existence DS-410 IP68/IP69K PUR / PU min 30 ms; Default 200 MS (Dependent On Filter Settings) 10 - 30 VDC 0.004 °/ K Minimum 20 k bore rate, up to 1 m bore rate 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) 0.34 mm² / AWG 22 ± 0.10 ° 2 axis measurement and horizontal measurement 10 m [394 "] Canopen 0.01 ° -40 ° C (-40 ° f)-+85 ° C (+185 ° F)
TILTIX tilted meter ACS-◯◯◯ -CA01-Part Number-ACS-090-2-CA01-HK3-AW

ACS-090-2-CA01-HK3-AW

Available upon quote Cable 10 m ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC 1H 125 k bore rate Horizon Din en 61000-6-2 Din en 61000-6-4 Zinc ≤ 100 g (Half Sign 6 MS, EN 60068-27) ± 90 ° 350 YEARS @ 40 ℃ -40 ° C (-40 ° f) -+80 ° C (+176 ° F) Desc Existence Existence DS-410 IP68/IP69K PUR / PU min 30 ms; Default 200 MS (Dependent On Filter Settings) 10 - 30 VDC 0.004 °/ K Minimum 20 k bore rate, up to 1 m bore rate 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) 0.34 mm² / AWG 22 ± 0.10 ° 2 axis measurement and horizontal measurement 10 m [394 "] Canopen 0.01 ° -40 ° C (-40 ° f)-+85 ° C (+185 ° F)
TILTIX tilted meter ACS-◯◯◯ -CA01-Part Number-ACS-180-F-CA01-VK3-PW

ACS-180-F-CA01-VK3-PW

Available upon quote Connector 2 x M12 (M+F) ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC 1H 125 k bore rate vertical Din en 61000-6-2 Din en 61000-6-4 Zinc ≤ 100 g (Half Sign 6 MS, EN 60068-27) Canopen 350 YEARS @ 40 ℃ -40 ° C (-40 ° f) -+80 ° C (+176 ° F) Desc Existence Existence DS-410 IP68/IP69K - min 30 ms; Default 200 MS (Dependent On Filter Settings) 10 - 30 VDC 0.004 °/ K Minimum 20 k bore rate, up to 1 m bore rate 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) - ± 0.10 ° 2 axis measurement and horizontal measurement - Canopen 0.01 ° -40 ° C (-40 ° f)-+85 ° C (+185 ° F)
TILTIX tilted meter ACS-◯◯◯ -CA01-Part Number-ACS-360-1-CA01-VE3-2W

ACS-360-1-CA01-VE3-2W

Available upon quote Cable 2 m ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC 1H 125 k bore rate vertical Din en 61000-6-2 Din en 61000-6-4 Fiber Enhancement PBT (Polybchiren Televaltarate) ≤ 100 g (Half Sign 6 MS, EN 60068-27) Max. 360 ° 350 YEARS @ 40 ℃ -30 ℃ Fixed (-22 ° f), -5 ° C Flexible (+23 ° F) -+80 ° C (+176 ° F) Desc Existence Existence DS-410 IP66/IP67 PVC min 30 ms; Default 200 MS (Dependent On Filter Settings) 10 - 30 VDC 0.004 °/ K Minimum 20 k bore rate, up to 1 m bore rate 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) 0.14 mm² / AWG 26 ± 0.10 ° 1 -axis measurement and vertical measurement 2 M [79 "] Canopen 0.01 ° -40 ° C (-40 ° f)-+85 ° C (+185 ° F)
TILTIX tilted meter ACS-◯◯◯ -CA01-Part Number-ACS-360-1-CA01-VE3-5W

ACS-360-1-CA01-VE3-5W

Available upon quote Cable 5 m ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC 1H 125 k bore rate vertical Din en 61000-6-2 Din en 61000-6-4 Fiber Enhancement PBT (Polybchiren Televaltarate) ≤ 100 g (Half Sign 6 MS, EN 60068-27) Max. 360 ° 350 YEARS @ 40 ℃ -30 ℃ Fixed (-22 ° f), -5 ° C Flexible (+23 ° F) -+80 ° C (+176 ° F) Desc Existence Existence DS-410 IP66/IP67 PVC min 30 ms; Default 200 MS (Dependent On Filter Settings) 10 - 30 VDC 0.004 °/ K Minimum 20 k bore rate, up to 1 m bore rate 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) 0.14 mm² / AWG 26 ± 0.10 ° 1 -axis measurement and vertical measurement 5 M [197 "] Canopen 0.01 ° -40 ° C (-40 ° f)-+85 ° C (+185 ° F)
TILTIX tilted meter ACS-◯◯◯ -CA01-Part Number-ACS-180-F-CA01-VK3-PL

ACS-180-F-CA01-VK3-PL

Available upon quote Connector 2 x M12 (M+F) ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC 1H 125 k bore rate vertical Din en 61000-6-2 Din en 61000-6-4 Zinc ≤ 100 g (Half Sign 6 MS, EN 60068-27) Canopen 350 YEARS @ 40 ℃ -40 ° C (-40 ° f) -+85 ℃ (+185 ° F) Desc Existence Existence DS-410 IP68/IP69K - min 30 ms; Default 200 MS (Dependent On Filter Settings) 10 - 30 VDC 0.004 °/ K Minimum 20 k bore rate, up to 1 m bore rate 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) - ± 0.10 ° 2 axis measurement and horizontal measurement - Canopen 0.01 ° -40 ° C (-40 ° f)-+85 ° C (+185 ° F)
TILTIX tilted meter ACS-◯◯◯ -CA01-Part Number-ACS-360-1-CA01-VE3-AW

ACS-360-1-CA01-VE3-AW

Available upon quote Cable 10 m ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC 1H 125 k bore rate vertical Din en 61000-6-2 Din en 61000-6-4 Fiber Enhancement PBT (Polybchiren Televaltarate) ≤ 100 g (Half Sign 6 MS, EN 60068-27) Max. 360 ° 350 YEARS @ 40 ℃ -30 ℃ Fixed (-22 ° f), -5 ° C Flexible (+23 ° F) -+80 ° C (+176 ° F) Desc Existence Existence DS-410 IP66/IP67 PVC min 30 ms; Default 200 MS (Dependent On Filter Settings) 10 - 30 VDC 0.004 °/ K Minimum 20 k bore rate, up to 1 m bore rate 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) 0.14 mm² / AWG 26 ± 0.10 ° 1 -axis measurement and vertical measurement 10 m [394 "] Canopen 0.01 ° -40 ° C (-40 ° f)-+85 ° C (+185 ° F)
TILTIX tilted meter ACS-◯◯◯ -CA01-Part Number-ACS-180-E-CA01-HE3-AW

ACS-180-E-CA01-HE3-AW

Available upon quote Cable 10 m ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC 1H 125 k bore rate Horizon Din en 61000-6-2 Din en 61000-6-4 Fiber Enhancement PBT (Polybchiren Televaltarate) ≤ 100 g (Half Sign 6 MS, EN 60068-27) Canopen 350 YEARS @ 40 ℃ -30 ℃ Fixed (-22 ° f), -5 ° C Flexible (+23 ° F) -+80 ° C (+176 ° F) Desc Existence Existence DS-410 IP66/IP67 PVC min 30 ms; Default 200 MS (Dependent On Filter Settings) 10 - 30 VDC 0.004 °/ K Minimum 20 k bore rate, up to 1 m bore rate 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) 0.14 mm² / AWG 26 ± 0.10 ° 2 axis measurement and horizontal measurement 10 m [394 "] Canopen 0.01 ° -40 ° C (-40 ° f)-+85 ° C (+185 ° F)
TILTIX tilted meter ACS-◯◯◯ -CA01-Part Number-ACS-090-2-CA01-HK3-2W

ACS-090-2-CA01-HK3-2W

Available upon quote Cable 2 m ≤ 65 ma @ 10 v DC, ≤ 60 ma @ 24 V DC 1H 125 k bore rate Horizon Din en 61000-6-2 Din en 61000-6-4 Zinc ≤ 100 g (Half Sign 6 MS, EN 60068-27) ± 90 ° 350 YEARS @ 40 ℃ -40 ° C (-40 ° f) -+80 ° C (+176 ° F) Desc Existence Existence DS-410 IP68/IP69K PUR / PU min 30 ms; Default 200 MS (Dependent On Filter Settings) 10 - 30 VDC 0.004 °/ K Minimum 20 k bore rate, up to 1 m bore rate 1.5 mm (10 hz - 58 Hz) & ≤ 20 g (58 Hz to 2,000 Hz) 0.34 mm² / AWG 22 ± 0.10 ° 2 axis measurement and horizontal measurement - Canopen 0.01 ° -40 ° C (-40 ° f)-+85 ° C (+185 ° F)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of POSITAL -Fraba


View more products of POSITAL -Fraba

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree