All Categories

History

Small divide luminous spectromate SPG-120 series that divides light by wavelength-SPG-120UV
Small divide luminous spectromate SPG-120 series that divides light by wavelength-SPG-120S
Small divide luminous spectromate SPG-120 series that divides light by wavelength-SPG-120IR
Small divide luminous spectromate SPG-120 series that divides light by wavelength-SPG-120UV-REV
Small divide luminous spectromate SPG-120 series that divides light by wavelength-SPG-120S-REV
Small divide luminous spectromate SPG-120 series that divides light by wavelength-Shimadzu Seisakusho Co., Ltd.

Small divide luminous spectromate SPG-120 series that divides light by wavelength
Shimadzu Seisakusho Co., Ltd.

🧪 Chemical Industry Use 💻 Electronics & Electrical Use

Shimadzu Seisakusho Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

2.4hours

Very Fast Response


About This Product

The SPG-120 series is a monochrome meter that can be easily constructed and recombined. There are SPG-120 that can manually set wavelengths and SPG-120-REV that can drive high-speed wavelengths on PCs. A spectroscope is a device that divides light into wavelengths. In general, the light of many wavelengths is mixed. Speaking of the light that can be seen in the eyes, the white light is a mixture of light from the purple wavelength to the red -visible wavelength. Light can be divided by wavelength. The appearance of light divided into wavelengths is called "spectrum", and the light extracted from the spectrum within a certain wavelength range is called "monochromatic light". The device for obtaining the spectrum is called "spectroscopy", and the one aimed at obtaining a monochromatic light is called "monochrome meter".

■ Features of SPG-120 series

・ Options such as light-collected lenses, slits, detectors, etc. can be detached to the SPG-120 series without using tools. ・ By placing the entry / exit port ports on the coaxial, it is possible to build a system using an optical rail. ・ Applicable to various applications such as wavelength variable light sources combined with light sources and optical characteristics measurement devices combined with detector. ・ High efficiency, F = 3, bright concave, holographic, and diffraction lattice to get a high throughput. -Intracted a fixed angle mount, and boasts a high -images performance due to the optimization of the mounting lattice groove shape for the mount.

■ Expansion of hiring light and size

-The expanding angle of the firing light is θz = 9.3 (°) in the vertical direction of the slit, and horizontal spread angle θx = 5.6 (°). -The calculation value of the size of the image at a position 100 mm away from the slit is 1 mm and the image is 37.8 mm and 20.6 mm width.

■ How to select a spectroscope

-The way of driving the wavelength is to manually set the SPG-120, and a method of combining options with SPG-120 and SPG-120-REV to control PC. ・ We recommend high-speed wavelength driving and highly durable SPG-120-REV for embedded devices. ・ There are three types: UV (190-700 nm), S (200-900Nm), and IR (700 to 2,500 nm) depending on the wavelength band. -The efficiency of UV and S crosses at about 300 nm, and if you use 300nm or less mainly, choose a UV.

  • Product

    Small divide luminous spectromate SPG-120 series that divides light by wavelength
  • Usage Scenarios

    Chemical Industry Use / Electronics & Electrical Use

Share this product


780+ people viewing

Last viewed: 38 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

6 Models of Small divide luminous spectromate SPG-120 series that divides light by wavelength

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Wavelength scanning method P/n Wavelength range Wavelength scale Spectroscopy Focal length Diffraction grating Mizomoto number Blaze wavelength Diffraction efficiency F -number Reverse line dispersion Wavelength accuracy Repeated wavelength accuracy resolution Wavelength drive Maximum wavelength drive speed Configuration movement pitch Enrollment shooting light slit External dimensions mass Operation temperature and humidity range
Small divide luminous spectromate SPG-120 series that divides light by wavelength-Part Number-SPG-120UV

SPG-120UV

Available upon quote

Autograph -bar system

691-05300-04

190nm ~ 700nm

3 -digit digital dial direct reading method

Head -to -face lattice
Classic angle monochrome meter

122.6mm

Design correction type concave blaze
Holographic diffraction lattice

1,200 ± 2/mm

250 ± 25nm

over 50

F = 3

5.7nm/mm

± 1.5nm

± 0.3nm

1nm

Options: Wavelength drive device AT-120PLM
Motor Controller SHOT-702H (Sigma Human), Others

50nm/s

0.1nm

Options: Bundle Fiber, FC Fiber Conector
SMA Fiber Connector, Xenon Lamp Tumor Lens, etc.

Options: 100 μm, 200 μm
500 μm, 1mm, 2mm

W100mm x H110mm x D181mm (excluding protrusion)

2.4kg

10 ℃ ~ 40 ℃
70%or less

Small divide luminous spectromate SPG-120 series that divides light by wavelength-Part Number-SPG-120S

SPG-120S

Available upon quote

Autograph -bar system

691-05300-01

200Nm ~ 900nm

3 -digit digital dial direct reading method

Head -to -face lattice
Classic angle monochrome meter

122.6mm

Design correction type concave blaze
Holographic diffraction lattice

1,200 ± 2/mm

350 ± 35nm

over 50

F = 3

5.7nm/mm

± 1.5nm

± 0.3nm

1nm

Options: Wavelength drive device AT-120PLM
Motor Controller SHOT-702H (Sigma Human), Others

50nm/s

0.1nm

Options: Bundle Fiber, FC Fiber Conector
SMA Fiber Connector, Xenon Lamp Tumor Lens, etc.

Options: 100 μm, 200 μm
500 μm, 1mm, 2mm

W100mm x H110mm x D181mm (excluding protrusion)

2.4kg

10 ℃ ~ 40 ℃
70%or less

Small divide luminous spectromate SPG-120 series that divides light by wavelength-Part Number-SPG-120IR

SPG-120IR

Available upon quote

Autograph -bar system

691-05300-03

700nm ~ 2,500Nm

4 digit digital dial direct reading method

Head -to -face lattice
Classic angle monochrome meter

122.6mm

Design correction type concave blaze
Holographic diffraction lattice

600 ± 2/mm

1,000nm ± 100nm

over 50

F = 3

10.0nm/mm

± 2.5nm

± 0.5nm

2nm

Options: Wavelength drive device AT-120PLM
Motor Controller SHOT-702H (Sigma Human), Others

100nm/s

0.1nm

Options: Bundle Fiber, FC Fiber Conector
SMA Fiber Connector, Xenon Lamp Tumor Lens, etc.

Options: 100 μm, 200 μm
500 μm, 1mm, 2mm

W100mm x H110mm x D181mm (excluding protrusion)

2.4kg

10 ℃ ~ 40 ℃
70%or less

Small divide luminous spectromate SPG-120 series that divides light by wavelength-Part Number-SPG-120UV-REV

SPG-120UV-REV

Available upon quote

Motor direct mission method

691-05640-02

190nm ~ 700nm

-

Head -to -face lattice
Classic angle monochrome meter

122.6mm

Design correction type concave blaze
Holographic diffraction lattice

1,200 ± 2/mm

250 ± 25nm

over 50

F = 3

5.7nm/mm

± 1.5nm

± 0.3nm

1nm

Options: motor controller
SHOT-702H (Sigma Hikari)

500nm/s

0.1nm

Options: Bundle Fiber, FC Fiber Conector
SMA Fiber Connector, Xenon Lamp Tumor Lens, etc.

Options: 100 μm, 200 μm
500 μm, 1 mm, 2mm

W100mm x H160mm x D187mm (excluding protrusion)

3.0kg

10 ℃ ~ 40 ℃
70%or less

Small divide luminous spectromate SPG-120 series that divides light by wavelength-Part Number-SPG-120S-REV

SPG-120S-REV

Available upon quote

Motor direct mission method

691-05640-01

200Nm ~ 900nm

-

Head -to -face lattice
Classic angle monochrome meter

122.6mm

Design correction type concave blaze
Holographic diffraction lattice

1,200 ± 2/mm

350 ± 35nm

over 50

F = 3

5.7nm/mm

± 1.5nm

± 0.3nm

1nm

Options: motor controller
SHOT-702H (Sigma Hikari)

500nm/s

0.1nm

Options: Bundle Fiber, FC Fiber Conector
SMA Fiber Connector, Xenon Lamp Tumor Lens, etc.

Options: 100 μm, 200 μm
500 μm, 1 mm, 2mm

W100mm x H160mm x D187mm (excluding protrusion)

3.0kg

10 ℃ ~ 40 ℃
70%or less

Small divide luminous spectromate SPG-120 series that divides light by wavelength-Part Number-SPG-120IR-REV

SPG-120IR-REV

Available upon quote

Motor direct mission method

691-05640-03

700nm ~ 2,500Nm

-

Head -to -face lattice
Classic angle monochrome meter

122.6mm

Design correction type concave blaze
Holographic diffraction lattice

600 ± 2/mm

1,000 ± 100nm

over 50

F = 3

10.0nm/mm

± 2.5nm

± 0.5nm

2nm

Options: motor controller
SHOT-702H (Sigma Hikari)

1,000nm/s

0.1nm

Options: Bundle Fiber, FC Fiber Conector
SMA Fiber Connector, Xenon Lamp Tumor Lens, etc.

Options: 100 μm, 200 μm
500 μm, 1 mm, 2mm

W100mm x H160mm x D187mm (excluding protrusion)

3.0kg

10 ℃ ~ 40 ℃
70%or less

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Spectrum Analyzers Products

Other products of Shimadzu Seisakusho Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Shimadzu Seisakusho Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

2.4hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree