Small divide luminous spectromate SPG-120 series that divides light by wavelength-SPG-120UV
Small divide luminous spectromate SPG-120 series that divides light by wavelength-SPG-120S
Small divide luminous spectromate SPG-120 series that divides light by wavelength-SPG-120IR
Small divide luminous spectromate SPG-120 series that divides light by wavelength-SPG-120UV-REV
Small divide luminous spectromate SPG-120 series that divides light by wavelength-SPG-120S-REV
Small divide luminous spectromate SPG-120 series that divides light by wavelength-Shimadzu Seisakusho Co., Ltd.

Small divide luminous spectromate SPG-120 series that divides light by wavelength
Shimadzu Seisakusho Co., Ltd.

🧪 Chemical Industry Use 💻 Electronics & Electrical Use

About This Product

The SPG-120 series is a monochrome meter that can be easily constructed and recombined. There are SPG-120 that can manually set wavelengths and SPG-120-REV that can drive high-speed wavelengths on PCs. A spectroscope is a device that divides light into wavelengths. In general, the light of many wavelengths is mixed. Speaking of the light that can be seen in the eyes, the white light is a mixture of light from the purple wavelength to the red -visible wavelength. Light can be divided by wavelength. The appearance of light divided into wavelengths is called "spectrum", and the light extracted from the spectrum within a certain wavelength range is called "monochromatic light". The device for obtaining the spectrum is called "spectroscopy", and the one aimed at obtaining a monochromatic light is called "monochrome meter". ■ Features of SPG-120 series ・ Options such as light-collected lenses, slits, detectors, etc. can be detached to the SPG-120 series without using tools. ・ By placing the entry / exit port ports on the coaxial, it is possible to build a system using an optical rail. ・ Applicable to various applications such as wavelength variable light sources combined with light sources and optical characteristics measurement devices combined with detector. ・ High efficiency, F = 3, bright concave, holographic, and diffraction lattice to get a high throughput. -Intracted a fixed angle mount, and boasts a high -images performance due to the optimization of the mounting lattice groove shape for the mount. ■ Expansion of hiring light and size -The expanding angle of the firing light is θz = 9.3 (°) in the vertical direction of the slit, and horizontal spread angle θx = 5.6 (°). -The calculation value of the size of the image at a position 100 mm away from the slit is 1 mm and the image is 37.8 mm and 20.6 mm width. ■ How to select a spectroscope -The way of driving the wavelength is to manually set the SPG-120, and a method of combining options with SPG-120 and SPG-120-REV to control PC. ・ We recommend high-speed wavelength driving and highly durable SPG-120-REV for embedded devices. ・ There are three types: UV (190-700 nm), S (200-900Nm), and IR (700 to 2,500 nm) depending on the wavelength band. -The efficiency of UV and S crosses at about 300 nm, and if you use 300nm or less mainly, choose a UV.

  • Product

    Small divide luminous spectromate SPG-120 series that divides light by wavelength
  • Usage Scenarios

    Chemical Industry Use / Electronics & Electrical Use

Share this product


670+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

6 Models of Small divide luminous spectromate SPG-120 series that divides light by wavelength

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Blaze wavelength Configuration movement pitch Diffraction efficiency Diffraction grating Enrollment shooting light External dimensions F -number Focal length Maximum wavelength drive speed Mizomoto number Operation temperature and humidity range P/n Repeated wavelength accuracy Reverse line dispersion Spectroscopy Wavelength accuracy Wavelength drive Wavelength range Wavelength scale Wavelength scanning method mass resolution slit
Small divide luminous spectromate SPG-120 series that divides light by wavelength-Part Number-SPG-120UV

SPG-120UV

Available upon quote 250 ± 25nm 0.1nm over 50 Design correction type concave blaze
Holographic diffraction lattice
Options: Bundle Fiber, FC Fiber Conector
SMA Fiber Connector, Xenon Lamp Tumor Lens, etc.
W100mm x H110mm x D181mm (excluding protrusion) F = 3 122.6mm 50nm/s 1,200 ± 2/mm 10 ℃ ~ 40 ℃
70%or less
691-05300-04 ± 0.3nm 5.7nm/mm Head -to -face lattice
Classic angle monochrome meter
± 1.5nm Options: Wavelength drive device AT-120PLM
Motor Controller SHOT-702H (Sigma Human), Others
190nm ~ 700nm 3 -digit digital dial direct reading method Autograph -bar system 2.4kg 1nm Options: 100 μm, 200 μm
500 μm, 1mm, 2mm
Small divide luminous spectromate SPG-120 series that divides light by wavelength-Part Number-SPG-120S

SPG-120S

Available upon quote 350 ± 35nm 0.1nm over 50 Design correction type concave blaze
Holographic diffraction lattice
Options: Bundle Fiber, FC Fiber Conector
SMA Fiber Connector, Xenon Lamp Tumor Lens, etc.
W100mm x H110mm x D181mm (excluding protrusion) F = 3 122.6mm 50nm/s 1,200 ± 2/mm 10 ℃ ~ 40 ℃
70%or less
691-05300-01 ± 0.3nm 5.7nm/mm Head -to -face lattice
Classic angle monochrome meter
± 1.5nm Options: Wavelength drive device AT-120PLM
Motor Controller SHOT-702H (Sigma Human), Others
200Nm ~ 900nm 3 -digit digital dial direct reading method Autograph -bar system 2.4kg 1nm Options: 100 μm, 200 μm
500 μm, 1mm, 2mm
Small divide luminous spectromate SPG-120 series that divides light by wavelength-Part Number-SPG-120IR

SPG-120IR

Available upon quote 1,000nm ± 100nm 0.1nm over 50 Design correction type concave blaze
Holographic diffraction lattice
Options: Bundle Fiber, FC Fiber Conector
SMA Fiber Connector, Xenon Lamp Tumor Lens, etc.
W100mm x H110mm x D181mm (excluding protrusion) F = 3 122.6mm 100nm/s 600 ± 2/mm 10 ℃ ~ 40 ℃
70%or less
691-05300-03 ± 0.5nm 10.0nm/mm Head -to -face lattice
Classic angle monochrome meter
± 2.5nm Options: Wavelength drive device AT-120PLM
Motor Controller SHOT-702H (Sigma Human), Others
700nm ~ 2,500Nm 4 digit digital dial direct reading method Autograph -bar system 2.4kg 2nm Options: 100 μm, 200 μm
500 μm, 1mm, 2mm
Small divide luminous spectromate SPG-120 series that divides light by wavelength-Part Number-SPG-120UV-REV

SPG-120UV-REV

Available upon quote 250 ± 25nm 0.1nm over 50 Design correction type concave blaze
Holographic diffraction lattice
Options: Bundle Fiber, FC Fiber Conector
SMA Fiber Connector, Xenon Lamp Tumor Lens, etc.
W100mm x H160mm x D187mm (excluding protrusion) F = 3 122.6mm 500nm/s 1,200 ± 2/mm 10 ℃ ~ 40 ℃
70%or less
691-05640-02 ± 0.3nm 5.7nm/mm Head -to -face lattice
Classic angle monochrome meter
± 1.5nm Options: motor controller
SHOT-702H (Sigma Hikari)
190nm ~ 700nm - Motor direct mission method 3.0kg 1nm Options: 100 μm, 200 μm
500 μm, 1 mm, 2mm
Small divide luminous spectromate SPG-120 series that divides light by wavelength-Part Number-SPG-120S-REV

SPG-120S-REV

Available upon quote 350 ± 35nm 0.1nm over 50 Design correction type concave blaze
Holographic diffraction lattice
Options: Bundle Fiber, FC Fiber Conector
SMA Fiber Connector, Xenon Lamp Tumor Lens, etc.
W100mm x H160mm x D187mm (excluding protrusion) F = 3 122.6mm 500nm/s 1,200 ± 2/mm 10 ℃ ~ 40 ℃
70%or less
691-05640-01 ± 0.3nm 5.7nm/mm Head -to -face lattice
Classic angle monochrome meter
± 1.5nm Options: motor controller
SHOT-702H (Sigma Hikari)
200Nm ~ 900nm - Motor direct mission method 3.0kg 1nm Options: 100 μm, 200 μm
500 μm, 1 mm, 2mm
Small divide luminous spectromate SPG-120 series that divides light by wavelength-Part Number-SPG-120IR-REV

SPG-120IR-REV

Available upon quote 1,000 ± 100nm 0.1nm over 50 Design correction type concave blaze
Holographic diffraction lattice
Options: Bundle Fiber, FC Fiber Conector
SMA Fiber Connector, Xenon Lamp Tumor Lens, etc.
W100mm x H160mm x D187mm (excluding protrusion) F = 3 122.6mm 1,000nm/s 600 ± 2/mm 10 ℃ ~ 40 ℃
70%or less
691-05640-03 ± 0.5nm 10.0nm/mm Head -to -face lattice
Classic angle monochrome meter
± 2.5nm Options: motor controller
SHOT-702H (Sigma Hikari)
700nm ~ 2,500Nm - Motor direct mission method 3.0kg 2nm Options: 100 μm, 200 μm
500 μm, 1 mm, 2mm

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Shimadzu Seisakusho Co., Ltd.


View more products of Shimadzu Seisakusho Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree