Product
Lineup abundant outdoor air cold chiller CN seriesHandling Company
Masaie Co., Ltd.Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Aquarium capacity (actual water) (L) | Cooling ability (KW) 10 ℃ 50Hz * 32 ° C | Cooling ability (KW) 15 ℃ 50Hz * 32 ° C | Cooling ability (KW) 15 ℃ 60Hz * 32 ° C | Cooling ability (KW) 20 ℃ 50Hz * 32 ° C | Cooling ability (KW) 20 ℃ 60Hz * 32 ° C | Cooling ability (KW) 25 ℃ 50Hz * 32 ° C | Cooling ability (KW) 5 ℃ 50Hz * 32 ° C | Cooling ability (KW) 5 ℃ 60Hz * 32 ° C | Cooling ability (kW) 10 ℃ 60Hz * 32 ° C | Cooling ability (kW) 25 ℃ 60Hz * 32 ° C | Electric specification circulation pump circulation (L/min) | Electrical specification circulation pump call output (W) | Electrical specification fan motor control | Electrical specification fan motor output (W) | Product weight | Protection device circulation pump | Protection device fan | Protection device refrigerant circuit | Protective device compressor | Protective device cooling pump | Protective device electric circuit | Protective device temperature control organs | Protective device water circuit | Refrigerant control | Refrigerant control method | Used refrigerant | air conditioner | power supply |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CN-2200A |
Available upon quote | 100 | 5.7 | 7.3 | 7.5 | 8 | 8.6 | 8.1 | 4.2 | 4.3 | 5.6 | 9.2 | 35/62 (20m as much as Yang) | 300/510 | Pressure switch control or electronic fan controller | 8.8 | 250 | Overcurrent power retainer | Overcurrent power retainer | High pressure switch | Overcurrent power retainer | Overcurrent power retainer | Electrical leakage breaker anti -phase relay | Temperature abnormality (inside the aquarium) | Aquarium float switch to prevent freezing thermo | ON-OFF type | Constant pressure | R-407C | Digital temperature with abnormal contact points | AC200V 50/60Hz 3PH | |
CN-3750A |
Available upon quote | 115 | 10.2 | 11.7 | 13.2 | 13.2 | 14.4 | 13.9 | 7.6 | 8.9 | 11.4 | 14.6 | 60/115 (20m as much as Yang) | 565/893 | Pressure switch control or electronic fan controller | 12.3 | 280 | Overcurrent power retainer | Overcurrent power retainer | High pressure switch | Overcurrent power retainer | Overcurrent power retainer | Electrical leakage breaker anti -phase relay | Temperature abnormality (inside the aquarium) | Aquarium float switch to prevent freezing thermo | ON-OFF type | Constant pressure | R-407C | Digital temperature with abnormal contact points | AC200V 50/60Hz 3PH | |
CN-5500A |
Available upon quote | 190 | 16.2 | 18.5 | 18.7 | 19.8 | 20.2 | 19.8 | 14 | 14.5 | 17.6 | 20.9 | 60/115 (20m as much as Yang) | 565/893 | Pressure switch control or electronic fan controller | 17.7 | 350 | Overcurrent power retainer | Overcurrent power retainer | High low pressure pressure switch | Overcurrent power retainer | Overcurrent power retainer | Electrical leakage breaker anti -phase relay | Temperature abnormality (inside the aquarium) | Aquarium float switch to prevent freezing thermo | ON-OFF type | Constant pressure | R-407C | Digital temperature with abnormal contact points | AC200V 50/60Hz 3PH | |
CN-7500A |
Available upon quote | 205 | 22.9 | 25.1 | 26.6 | 26.9 | 28.1 | 27.6 | 16.7 | 18.3 | 24.6 | 29 | 90/130 (20m as much as Yang) | 771/1,202 | Pressure switch control or electronic fan controller | 21.9 | 450 | Overcurrent power retainer | Overcurrent power retainer | High low pressure pressure switch | Overcurrent power retainer | Overcurrent power retainer | Electrical leakage breaker anti -phase relay | Temperature abnormality (inside the aquarium) | Aquarium float switch to prevent freezing thermo | ON-OFF type | Constant pressure | R-407C | Digital temperature with abnormal contact points | AC200V 50/60Hz 3PH |
Click on the part number for more information about each product