All Categories
History
Product
FA Sensor Pressure Sensor/Flow Rate Sensor Digital Pressure Sensor [For Gas] DP-0Handling Company
Panasonic Industry Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Earthing method | Usage altitude | Output operation | Type of pressure | Pressure port | Rated pressure range | Comparison output NPN output type | Comparison output PNP output type | Comparison output Hysteresis | Comparison output response time | Comparison output short circuit protection | Comparison output Repeatability | Pollution degree | Power consumption | Temperature characteristics (based on +20℃) | Pressure resistance | Environmental resistance Operating ambient temperature | Environmental resistance Ambient humidity | Environmental resistance Protective structure | Environmental resistance Insulation resistance | Environmental resistance Vibration resistance | Environmental resistance Impact resistance | Environmental resistance Voltage resistance | Display | Display pressure range | Setting pressure range | Overvoltage category | Compliance regulations | Applicable fluid | Power supply voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
DP-001Z |
Available upon quote |
Floating |
2,000m or less |
Select NO/NC by key operation |
Gauge pressure |
M5 female thread |
-100.0~+100.0kPa |
NPN transistor open collector |
PNP transistor open collector |
Minimum 2digits (variable) |
2.5ms, 25ms, 250ms Select by key operation |
Equipment |
±0.2%F.S. (within ±4digits) |
2 |
30mA or less |
+10~+40℃: Within ±1%F.S. |
500kPa |
0~+50℃ (no condensation), Storage: -10~+60℃ |
35~85%RH, during storage: 35~85%RH |
IP40 (IEC) |
50MΩ or more at DC500V megger, between all charging parts and case |
Durability 10~150Hz Double amplitude 0.75mm or maximum acceleration 49m/s2 2 hours each in XYZ directions |
Durability 100m/s2 (approx. 10G) 3 times in each direction of XYZ |
AC500V for 1 minute, all live parts and between cases |
3+1/2 digits, 3 colors (white/red/pink) LCD display (display update cycle: 250ms) |
-101.0~+101.0kPa |
101.0~+101.0kPa |
I |
CE marking (EMC directive, RoHS directive), UKCA marking (EMC regulation, RoHS regulation) |
Air, non-corrosive gas |
12~24V DC±10% Ripple P-P 10% or less |