FA sensor Pressure sensor/Flow rate sensor IO-Link compatible 2-screen digital pressure sensor [For gas] DP-100L-DP-101ZL3-M-P
FA sensor Pressure sensor/Flow rate sensor IO-Link compatible 2-screen digital pressure sensor [For gas] DP-100L-Panasonic Industry Co., Ltd.

FA sensor Pressure sensor/Flow rate sensor IO-Link compatible 2-screen digital pressure sensor [For gas] DP-100L
Panasonic Industry Co., Ltd.


About This Product

basic information

■Self-monitoring function informs superiors of one's "status"

Obtained UL/C-UL, CE, UKCA. (UL: Recognition certified) Features

■Reducing the burden of data analysis, IoT starts with a small step. IO-Link compatible Collects sensor level data

On-site data collected and accumulated for "preventive maintenance" and "operation monitoring". Analyzing this data requires advanced know-how and time, which is a burden on production sites. Panasonic Industry's "Self-Monitoring Sensor" sends sensor data to the upper layer via IO-Link, and also communicates the sensor's own "status" to the upper layer, reducing the amount of data collected and the burden of data analysis.

■IoT made easy

By monitoring the status of self-monitoring sensors, you can easily perform preventive maintenance.

■Dual screen display allows direct setting of threshold values

□Equipped with 2 screens in a compact size of 30mm. Since you can check the current value and threshold at the same time, you can smoothly check and set the threshold without changing the screen mode. Since the ON/OFF operation is performed even while setting the threshold value, settings can be made in the same way as a volume type sensor. Of course, it is also equipped with a key lock function.

■3-color display (red, green, orange)

The main display changes color in conjunction with the output ON/OFF operation, and also changes color during settings. This makes it easier to understand the sensor status and reduces operational errors.

■Easy to read digital display

Adopts alphanumeric display using 12 segments. Improved visibility of alphanumeric characters.

■Sensor setting operation mode has a 3-layer structure according to the frequency of use

We have clearly differentiated the level of settings: "RUN mode" for daily operation settings, "Menu setting mode" for basic settings, and "PRO mode" for high-level functions. Setting operations are easy to understand and easy.

■Displays orange while setting

In the RUN state, the display will be displayed in green/red, but during settings it will always be displayed in orange, allowing you to see the sensor status at a glance.

■Easy-to-use initial settings

The default settings are easy to use for applications where pressure sensors are used frequently. The low-pressure type is initially set to be optimal for suction confirmation, and the high-pressure type is ideal for source pressure confirmation. Reduces sensor setting work.

  • Product

    FA sensor Pressure sensor/Flow rate sensor IO-Link compatible 2-screen digital pressure sensor [For gas] DP-100L

Share this product


30+ people viewing

Last viewed: 1 hour ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of FA sensor Pressure sensor/Flow rate sensor IO-Link compatible 2-screen digital pressure sensor [For gas] DP-100L

Image Part Number Price (excluding tax) Digital display Digital display Display pressure range Output indicator light Control output (DO) Control output (DO) output mode Control output (DO) output operation Control output (DO) Hysteresis Control output (DO) response time Control output (DO) short circuit protection Control output (DO) repeatability Type of pressure Rated pressure range Power consumption ECO mode Power consumption Normal time Pressure resistance Environmental resistance Operating ambient temperature Environmental resistance Ambient humidity Environmental resistance Protective structure Environmental resistance Insulation resistance Environmental resistance Vibration resistance Environmental resistance Impact resistance Environmental resistance Voltage resistance Setting pressure range Communication output (C/Q) IO-Link communication Communication output (C/Q) process data Communication output (C/Q) transmission speed Communication output (C/Q) minimum cycle time Compliance regulations and certifications Applicable fluid Power supply voltage
FA sensor Pressure sensor/Flow rate sensor IO-Link compatible 2-screen digital pressure sensor [For gas] DP-100L-Part Number-DP-101ZL3-M-P

DP-101ZL3-M-P

Available upon quote

4-digit + 4-digit 3-color LCD display (Display update cycle: 250ms, 500ms, 1,000ms, selected by key operation)

-101.0~+101.0kPa

Orange LED
(Output operation indicator 1: Blinks during IO-Link communication, lights up when control output is ON during non-IO-Link communication (synchronized with output operation indicator 2)
Output operation indicator 2: Lights up when control output is ON)

PNP transistor open collector
• Maximum drain current: 50mA
• Applied voltage: 30V DC or less (between control output and +V)
• Residual voltage: 2V or less (at outflow current 50mA)

EASY mode / Hysteresis mode / Window comparator mode

Select N.O./N.C. by key operation

Minimum 1digit (variable)

2.5ms, 5ms, 10ms, 25ms, 50ms, 100ms, 250ms, 500ms, 1,000ms, 5,000ms Select by key operation

Equipment

±0.1%F.S. (within ±2digits)

Gauge pressure

-100.0~+100.0kPa

480mW or less at STD (current consumption 20mA or less when power supply voltage is 24V), 360mW or less at FULL (current consumption 15mA or less when power supply voltage is 24V)

720mW or less (current consumption 30mA or less when power supply voltage is 24V)

500kPa

-10~+50℃ (no condensation or freezing), Storage: -10~+60℃

35~85%RH, during storage: 35~85%RH

IP40 (IEC)

50MΩ or more at DC500V megger, between all charging parts and case

Durability 10~500Hz, double amplitude 3mm or maximum acceleration 196m/s2, 2 hours each in XYZ directions

Durability 100m/s2 (approx. 10G) 3 times in each direction of XYZ

AC1,000V for 1 minute, all live parts and between cases

101.0~+101.0kPa

IO-Link Specification V1.1

4byte

COM3 (230.4kbps)

1.0ms

CE marking (EMC directive, RoHS directive), UKCA marking (EMC regulation, RoHS regulation), UL/c-UL certification

Non-corrosive gas

12~24V DC±10% Ripple P-P 10% or less

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Pressure Sensors Products

Other products of Panasonic Industry Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Panasonic Industry Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree