All Categories
History
Product
FA Sensor Light Curtain/Safety Equipment Flameproof Explosion-proof Light Curtain [Type4 PLe SIL3] BSF4-AH80Handling Company
Panasonic Industry Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Optical axis pitch/detection distance | Control output (OSSD1, OSSD2) | Control output protection circuit (short circuit protection) | Control output operation mode (output operation) | Response time | Emission stop input | Light emission stop function | Minimum detectable object | Effective opening angle | Detection width | Explosion-proof performance Canada/Japan | Explosion-proof performance China | Explosion-proof performance Europe | Explosion-proof performance US | Environmental resistance Ambient temperature/humidity | Environmental resistance Ambient illuminance | Environmental resistance Protective structure | Environmental resistance Altitude (atmospheric pressure) | Environmental resistance Vibration/shock resistance | Environmental resistance Withstand voltage/insulation resistance | Auxiliary output (non-safety output) | Auxiliary output (non-safety output) Protection circuit (short circuit protection) | Auxiliary output (non-safety output) operating mode (output operation) | Installation location | Applicable standards Canada | Applicable standards China | Applicable standards United States | Applicable explosion-proof standards Japan | Applicable explosion-proof standards Europe | Power supply voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
BSF4-AH80 |
Available upon quote |
20mm/0.3~6m |
Semiconductor output (PNP equivalent) 2 outputs |
Equipment |
ON when all optical axes receive light, OFF when one or more optical axes are blocked (also OFF when there is an error inside the safety light curtain or a synchronization signal error) |
OFF response 11ms or less, ON response 70ms or less |
Light emission: Vs-2.5V~Vs (inflow current 5mA or less), light emission stop: open or 0~+1.5V |
Equipment |
Φ30mm opaque body |
±2.5° or less when the detection distance exceeds 3m (according to IEC 61496-2/UL 61496-2) |
1,595mm |
Ex d IIB T6 |
Ex d IIB T6 Gb |
Ex db[op is] IIB T6 Gb |
Class I, Zone 1 AEx d IIB T6 |
-10~+40℃ (However, no condensation or freezing), Storage: -20~+55℃ / 45~85%RH, Storage: 45~85%RH |
Incandescent lamp: Light receiving surface illuminance 5,000 lx or less |
IP65 (IEC) |
Less than 2,000m (800~1,100hPa) |
Durability 10~55Hz Double amplitude 0.35mm 20 times in each direction of XYZ / Durability 100m/s2 (approx. 10G) Pulse time 16ms 1,000 times in each direction of XYZ |
AC1,000V for 1 minute between all live parts and the main body ground terminal / 20MΩ or more with DC500V megger between all live parts and the main body ground terminal |
PNP transistor open collector |
Equipment |
OFF when control output is ON, ON when control output is OFF |
Gas or steam Zone 1/Zone 2 hazardous areas equivalent to IIB T6 |
CAN/CSA-E60079 |
GB 3836.1-2010 (GB 3836.2-2010) |
FM 3600 (ANSI/ISA 12.22.01) |
Technical standards consistent with international standards |
EN IEC 60079-0, EN 60079-1, EN 60079-28 |
24V DC±10% Ripple P-P10% or less |