All Categories
History
Product
FA sensor Light curtain/safety equipment Ultra-thin safety light curtain [Type2 PLc SIL1] SF2CHandling Company
Panasonic Industry Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Test input function | Lockout output (SSD) 1 | Lockout output (SSD) 2 | Lockout output protection circuit (short circuit protection) | Lockout output operation mode (output operation) | Usage altitude | Optical axis pitch | Control output (OSSD) 1 | Control output (OSSD) 2 | Control output (OSSD) protection circuit (short circuit protection) | Control output (OSSD) operation mode (output operation) | Large app indicator light function | Interference prevention function | Response time | Minimum detectable object | Effective opening angle | Detection distance | Pollution degree | Environmental resistance Operating ambient temperature | Environmental resistance Ambient humidity | Environmental resistance Ambient illuminance | Environmental resistance Protective structure | Environmental resistance Insulation resistance | Environmental resistance Voltage resistance | Compliance regulations and certifications | Applicable standards North America | Compliant standards International standards | Compliant standards Japan | Compatible standards Europe | Power supply voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SF2C-H□-P |
Available upon quote |
Equipment |
・Maximum outflow current: 60mA |
・Leakage current: 200μA or less (including when power is OFF) |
Equipment |
ON during normal operation, OFF during lockout |
2,000m or less |
20mm |
・Maximum outflow current: 200mA |
・Leakage current: 200μA or less (including when power is OFF) |
Equipment |
ON when all optical axes receive light, OFF when one or more optical axes are blocked (also OFF when there is an error inside the safety light curtain or a synchronization signal error) |
Equipment |
Equipment |
When OFF: 20ms or less, When ON: 80~100ms |
Φ25mm opaque body |
±5° or less when the sensing distance is 3m (according to IEC 61496-2, ANSI/UL 61496-2) |
0.1~3m |
3 |
-10~+55℃ (no condensation or freezing), storage: -25~+60℃ |
30~85%RH, during storage: 30~85%RH |
Incandescent lamp: Light receiving surface illuminance 5,000ℓx or less |
IP65, IP67 (IEC) |
20MΩ or more at DC500V megger, between all live parts and case |
AC1,000V for 1 minute between all live parts and cases |
CE marking (Machine Directive, EMC Directive, RoHS Directive), UKCA marking (Machine Regulation, EMC Regulation, RoHS Regulation), TÜV SÜD certification, TÜV SÜD certification (USA/Canada) |
ANSI/UL 61496-1/2 (Type 2), ANSI/UL 508, CAN/CSA 61496-1/2 (Type 2), CAN/CSA C22.2 No.14, ANSI/RIA 15.06 |
IEC 61496-1/2 (Type 2), ISO 13849-1:2015 (Category 2, PLc), IEC 61508-1~3 (SIL1) |
JIS B 9704-1/2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL1) |
EN 61496-1 (Type 2), EN ISO 13849-1:2015 (Category 2, PLc), EN 61508-1~3 (SIL1), EN 55011, EN 50178, EN 61000-6-2 |
24V DC±20% Ripple P-P10% or less |