A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Vertical damper/horizontal damper type drainage, ventilation, rubber flexible for rainwater
A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Rubber flexible for vertical 1 type drainage / rainwater
A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Patent equipment Co., Ltd.

A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake
Patent equipment Co., Ltd.


About This Product

A seismic isolation building sways in a different cycle from the building and the ground when an earthquake occurs, causing great relative displacement among the two. At the same time as reducing the damage of the building itself, the lifeline facility pipe must be protected from the earthquake. The OS -type seismic isolation piping system is a unique system that absorbs major displacement in piping equipment. ■ Simple configuration It can be installed in a short time because it is a simple configuration that connects to the L -form using a seismic isolation flexible and elbow on the piping on the building side and the ground side, and supports the elbow part with a control damper with a level adjuster. ■ 3D seismic isolation is possible By adopting a control damper with a dumping mechanism and spring, three -dimensional seismic isolation is possible. ■ Easy construction Control damper and level adjuster are selected according to the terms of use, adjusted height and shipped. It is excellent in construction in the field, and can significantly reduce maintenance and management after construction. ■ There is no twist The control damper and elbow band have almost no twist in the piping fixed portion. ■ Abundant types We propose optimal systems from abundant types of control damper depending on the seismic amount, piping diameter and construction space. * There are other model numbers.

  • Product

    A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake




*Please note that we may not be able to accommodate sample requests.

10 Models of A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Attenuation mechanism Maximum use pressure Maximum used temperature Nominal diameter Seismic isolation flexible total length of seismic abomination 500mm Seismic isolation flexible total length of seismic abomination 600mm Seismic isolation flexible total length of seismic abomination 700mm
A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Part Number-Vertical damper/horizontal damper type drainage, ventilation, rubber flexible for rainwater

Vertical damper/horizontal damper type drainage, ventilation, rubber flexible for rainwater

Available upon quote Control damper 0.28MPa or less 70 ° C or less 20A ~ 300A 600 ~ 1,300mm 700 ~ 1,400mm 900 ~ 1,500mm
A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Part Number-Vertical damper/horizontal damper type rubber flexible for water supply, cooling water, cold water

Vertical damper/horizontal damper type rubber flexible for water supply, cooling water, cold water

Available upon quote Control damper 0.98MPa or less 70 ° C or less 20A ~ 300A 600 ~ 1,300mm 700 ~ 1,400mm 900 ~ 1,500mm
A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Part Number-Vertical damper/horizontal damper type SUS flexible for water supply/cooling water/cold water/steam

Vertical damper/horizontal damper type SUS flexible for water supply/cooling water/cold water/steam

Available upon quote Control damper 0.98MPa or less 300 ° C or less 20A ~ 300A 1,100 to 2,100mm 1,200 to 2,300mm 1,400 to 2,500mm
A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Part Number-Vertical damper/horizontal damper type fire extinguishing/fire extinguishing water (10k) SUS flexible

Vertical damper/horizontal damper type fire extinguishing/fire extinguishing water (10k) SUS flexible

Available upon quote Control damper 1.4MPa or less 300 ° C or less 32a ~ 200A 1,100 ~ 1,700mm 1,300 ~ 1,900mm 1,500 to 2,000mm
A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Part Number-Vertical damper/horizontal damper type fire extinguishing/fire extinguishing water (20k) SUS flexible

Vertical damper/horizontal damper type fire extinguishing/fire extinguishing water (20k) SUS flexible

Available upon quote Control damper 2.8MPa or less 300 ° C or less 32a ~ 200A 1,300 ~ 1,800mm 1,400 to 2,000mm 1,600 to 2,100mm
A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Part Number-Vertical damper/horizontal damper type oil SUS flexible

Vertical damper/horizontal damper type oil SUS flexible

Available upon quote Control damper 0.98MPa or less 300 ° C or less 15A ~ 100A 1,200 ~ 2,000mm 1,300 to 2,200mm 1,500 to 2,300mm
A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Part Number-Vertical damper/horizontal damper type SUS Flexi

Vertical damper/horizontal damper type SUS Flexi

Available upon quote Control damper 0.98MPa or less 270 ° C or less 20A ~ 200A 1,100 ~ 1,850mm 1,300 to 2,050mm 1,450 to 2,200mm
A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Part Number-Rubber flexible for vertical 1 type drainage / rainwater

Rubber flexible for vertical 1 type drainage / rainwater

Available upon quote - 0.28MPa or less 70 ° C or less 20A ~ 250A 900 ~ 1,400mm 900 ~ 1,600mm 1,100 ~ 1,800mm
A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Part Number-1 vertical type 1 type of water supply, cooling water, rubber flexible for cold water

1 vertical type 1 type of water supply, cooling water, rubber flexible for cold water

Available upon quote - 0.98MPa or less 70 ° C or less 20A ~ 250A 900 ~ 1,400mm 900 ~ 1,600mm 1,100 ~ 1,800mm
A seismic isolation piping method OS type seismic isolation piping system to protect equipment compression from an earthquake-Part Number-Vertical 1 type water supply, cooling water, cold water, steam, ventilation flexible

Vertical 1 type water supply, cooling water, cold water, steam, ventilation flexible

Available upon quote - 0.98MPa or less 300 ° C or less 20A ~ 125A 1,200 ~ 1,600mm 1,300 ~ 1,700mm 1,500 to 2,000mm

Click on the part number for more information about each product

Other products of Patent equipment Co., Ltd.


View more products of Patent equipment Co., Ltd.

About Company Handling This Product

Patent equipment Co., Ltd.

  • Japan
  • Since 1969
  • 305 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree