All Categories

History

Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD-8038HD
Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD-Teledyne LeCroy

Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD
Teledyne LeCroy

Teledyne LeCroy's Response Status

Response Rate

100.0%

Response Time

25.8hours

Relatively Fast Response


About This Product

■ Characteristics

・ 15.6 inch/touch screen 1,900 × 1,080 ・ Analog 8 channel input ・ Compatible with Probus Prove/Interface for teledine recreali probes ・ Tablet -like intuition operation with OneTouch Maui ・ Q-SCAPE, multi/tab display ・ Up to 5g points waveform capture memory ・ HD4096 High -resolution technologies are always 12 -bit ・ The button and knob that glow in the color according to the display color of the waveform ・ Currently cursor operation and set value change without opening the menu ・ Mixed signal function on 16 channels digital/port ・ 6 USB3.1 ports (front 2, horizontal 4) ・ HDMI external display port, 4K (4,096 × 2,304) external monitor/support ・ Removable SSD (standard) ・ 16 channels displayed when 2 units synchronized with OSCillosync ・ Input/output of synchronization with external devices/clock ・ High -speed remote control with USB3.1 (USBTMC)

■ HD4096 Technology Low noise & always 12 bits

Teledine/Recroy's 12 -bit high -resolution oscilloscope provides unusual measurement capacity that does not compromise using its own HD4096 technology. High -speed sampling, 12 -bit high resolution AD converter. Input amplorer with high SN ratio. (Up to 2 GHz) Low noise architecture. Once, if you experience the high -precision and high -definition HD4096 technology, you will not be able to return to the 8 -bit oscilloscope again. HD4096 technology provides unparalleled reliability and measurement, regardless of general design, debugging, high -precision sensor, power electronics, car electronics, mechatronics, etc.

■ Clear and clean waveform

Compared to the waveform captured by the conventional 8 -bit oscilloscope, the waveform captured by HD4096 12 -bit/technology is overwhelmingly clear, clean and more accurate. HD4096 If you look at the waveforms captured by technology, you will no longer be able to return to 8 -bit oscilloscope.

  • Product

    Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD

Share this product


360+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

4 Models of Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Analog bandwidth@50Ω (-3db) Analog bandwidth@1Ω (-3db) Rising time (10-90%, 50Ω-warranty value) Rising time (20-80%, 50Ω-representative value) Input channel Vertical decomposition ability Number of valid bits (ENOB) Vertical noise floor 1mv/Div ~ 1V/Div sensitivity DC gain accuracy (DC accuracy gain component) Channel between isolation Offset range Offset accuracy Maximum input voltage Input coupling Input impey dance Frequency band restriction Rescaling Horizontal axis -analog channel time base Time base range Clock accuracy Sampling Clock Jitter Descue range between channels See external time base (input) See external time base (output) Capture -Analog Channel sampling speed Standard memory long option (4ch / 2ch) Segment interval Average number interpolation
Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD-Part Number-8038HD

8038HD

Available upon quote

350MHz

350MHz

1NS

750ps

8

12 Bit Resolution Improvement Operation (ERES) Up to 15 bits when used

8.9

95μV ~ 2.95mv

50 Ω: 1 MV -1 V/DIV (consecutive variable variable settings), Fully Variable; 1 MΩ: 1 MV -10 V/DIV (consecutive variable settings)

Full scale ± 0.5%, offset 0V

70 DB @ DC ~ 200 MHz, 60 DB @ 200 ~ 350 MHz

50 Ω: 1 MV ~ 4.95 MV: ± 1.6 V; 5 MV ~ 9.9 MV: ± 4 V, 10 MV ~ 19.8 MV: ± 8 V; 20 MV ~ 1 V: ± 10 V

± (0.5% of offset value + 0.5% + 1 MV of full scale)

50 Ω: 5 VRMS, ± 10V peak, 1 mΩ: 400 V Max (DC + Peak AC ≤ 10 kHz)

1 mΩ: AC, DC, GND; 50 ω: DC, GND

50 Ω: ± 2.0%; 1 mΩ: 19 PF, 10 mΩ: 10 PF

20 MHz, 200 MHz

Length: meters, inch, feet, yard, mile/mass: gram, slag/temperature: Hana, Kelvin/angle: Radian, ARCDEGR, minute, cycle, cycle, turn, turn

The internal time base is common to 8 input

100 ps/div ~ 5 ks/div (up to 10 ks/div for 500MPT memo application, up to 25 ks/div for 1000Mpt memo application

± 1 PPM calibration+ 1 ppm/year

Capture time range up to 10US: 80 FSRMS (see internal time base), 10ms capture time range: 150 FSRMS (see internal time base)

± 9 × Time/Div, up to 100ms, each channel

10MHz ± 25ppm (0 ~ 10dbm, 50Ω input)

10MHz 5.0dbm ± 2.5dbm, synchronization with the time base of the oscilloscope (internal or external reference)

10Gs/S (Enhanced Sampling)

Standard: 50m points/100m points/200m points (65,535 segments)

1.5 μs

Additional average: Up to 1 million sweep, continuous average: Up to 1 million sweep (≦ 500m point waveform)

Straight line interpolation or Sin X/X interpolation (2 or 5 points) (≦ 500m point waveform)

Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD-Part Number-8058HD

8058HD

Available upon quote

500MHz

500MHz

700ps

525ps

8

12 Bit Resolution Improvement Operation (ERES) Up to 15 bits when used

8.8

100μV ~ 3.15mv

50 Ω: 1 MV -1 V/DIV (consecutive variable variable settings), Fully Variable; 1 MΩ: 1 MV -10 V/DIV (consecutive variable settings)

Full scale ± 0.5%, offset 0V

70 DB @ DC ~ 200 MHz, 60 DB @ 200 ~ 500 MHz

50 Ω: 1 MV ~ 4.95 MV: ± 1.6 V; 5 MV ~ 9.9 MV: ± 4 V, 10 MV ~ 19.8 MV: ± 8 V; 20 MV ~ 1 V: ± 10 V

± (0.5% of offset value + 0.5% + 1 MV of full scale)

50 Ω: 5 VRMS, ± 10V peak, 1 mΩ: 400 V Max (DC + Peak AC ≤ 10 kHz)

1 mΩ: AC, DC, GND; 50 ω: DC, GND

50 Ω: ± 2.0%; 1 mΩ: 19 PF, 10 mΩ: 10 PF

20 MHz, 200 MHz, 350 MHz

Length: meters, inch, feet, yard, mile/mass: gram, slag/temperature: Hana, Kelvin/angle: Radian, ARCDEGR, minute, cycle, cycle, turn, turn

The internal time base is common to 8 input

100 ps/div ~ 5 ks/div (up to 10 ks/div for 500MPT memo application, up to 25 ks/div for 1000Mpt memo application

± 1 PPM calibration+ 1 ppm/year

Capture time range up to 10US: 80 FSRMS (see internal time base), 10ms capture time range: 150 FSRMS (see internal time base)

± 9 × Time/Div, up to 100ms, each channel

10MHz ± 25ppm (0 ~ 10dbm, 50Ω input)

10MHz 5.0dbm ± 2.5dbm, synchronization with the time base of the oscilloscope (internal or external reference)

10Gs/S (Enhanced Sampling)

Standard: 50m points/100m points/200m points (65,535 segments)

1.5 μs

Additional average: Up to 1 million sweep, continuous average: Up to 1 million sweep (≦ 500m point waveform)

Straight line interpolation or Sin X/X interpolation (2 or 5 points) (≦ 500m point waveform)

Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD-Part Number-8108HD

8108HD

Available upon quote

1GHz

500MHz

400ps

300ps

8

12 Bit Resolution Improvement Operation (ERES) Up to 15 bits when used

8.6

130 μV ~ 4.00mv

50 Ω: 1 MV -1 V/DIV (consecutive variable variable settings), Fully Variable; 1 MΩ: 1 MV -10 V/DIV (consecutive variable settings)

Full scale ± 0.5%, offset 0V

70 DB @ DC ~ 200 MHz, 60 DB @ 200 ~ 500 MHz, 50 DB @ 500 ~ 1 GHz

50 Ω: 1 MV ~ 4.95 MV: ± 1.6 V; 5 MV ~ 9.9 MV: ± 4 V, 10 MV ~ 19.8 MV: ± 8 V; 20 MV ~ 1 V: ± 10 V

± (0.5% of offset value + 0.5% + 1 MV of full scale)

50 Ω: 5 VRMS, ± 10V peak, 1 mΩ: 400 V Max (DC + Peak AC ≤ 10 kHz)

1 mΩ: AC, DC, GND; 50 ω: DC, GND

50 Ω: ± 2.0%; 1 mΩ: 19 PF, 10 mΩ: 10 PF

20 MHz, 200 MHz, 350 MHz, 500MHz

Length: meters, inch, feet, yard, mile/mass: gram, slag/temperature: Hana, Kelvin/angle: Radian, ARCDEGR, minute, cycle, cycle, turn, turn

The internal time base is common to 8 input

100 ps/div ~ 5 ks/div (up to 10 ks/div for 500MPT memo application, up to 25 ks/div for 1000Mpt memo application

± 1 PPM calibration+ 1 ppm/year

Capture time range up to 10US: 80 FSRMS (see internal time base), 10ms capture time range: 150 FSRMS (see internal time base)

± 9 × Time/Div, up to 100ms, each channel

10MHz ± 25ppm (0 ~ 10dbm, 50Ω input)

10MHz 5.0dbm ± 2.5dbm, synchronization with the time base of the oscilloscope (internal or external reference)

10Gs/S (Enhanced Sampling)

Standard: 50m points/100m points/200m points (65,535 segments)

1.5 μs

Additional average: Up to 1 million sweep, continuous average: Up to 1 million sweep (≦ 500m point waveform)

Straight line interpolation or Sin X/X interpolation (2 or 5 points) (≦ 500m point waveform)

Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD-Part Number-8208HD

8208HD

Available upon quote

2GHz

500MHz

235ps

176ps

8

12 Bit Resolution Improvement Operation (ERES) Up to 15 bits when used

8.4

170μV ~ 5.20mv

50 Ω: 1 MV -1 V/DIV (consecutive variable variable settings), Fully Variable; 1 MΩ: 1 MV -10 V/DIV (consecutive variable settings)

Full scale ± 0.5%, offset 0V

70 DB @ DC ~ 200 MHz, 60 DB @ 200 ~ 500 MHz, 50 DB @ 500 ~ 1 GHz, 40 DB @ 1GHz ~ 2GHz

50 Ω: 1 MV ~ 4.95 MV: ± 1.6 V; 5 MV ~ 9.9 MV: ± 4 V, 10 MV ~ 19.8 MV: ± 8 V; 20 MV ~ 1 V: ± 10 V

± (0.5% of offset value + 0.5% + 1 MV of full scale)

50 Ω: 5 VRMS, ± 10V peak, 1 mΩ: 400 V Max (DC + Peak AC ≤ 10 kHz)

1 mΩ: AC, DC, GND; 50 ω: DC, GND

50 Ω: ± 2.0%; 1 mΩ: 19 PF, 10 mΩ: 10 PF

20 MHz, 200 MHz, 350 MHz, 500MHz, 1GHz

Length: meters, inch, feet, yard, mile/mass: gram, slag/temperature: Hana, Kelvin/angle: Radian, ARCDEGR, minute, cycle, cycle, turn, turn

The internal time base is common to 8 input

100 ps/div ~ 5 ks/div (up to 10 ks/div for 500MPT memo application, up to 25 ks/div for 1000Mpt memo application

± 1 PPM calibration+ 1 ppm/year

Capture time range up to 10US: 80 FSRMS (see internal time base), 10ms capture time range: 150 FSRMS (see internal time base)

± 9 × Time/Div, up to 100ms, each channel

10MHz ± 25ppm (0 ~ 10dbm, 50Ω input)

10MHz 5.0dbm ± 2.5dbm, synchronization with the time base of the oscilloscope (internal or external reference)

10Gs/S (Enhanced Sampling)

Standard: 50m points/100m points/200m points (65,535 segments)

1.5 μs

Additional average: Up to 1 million sweep, continuous average: Up to 1 million sweep (≦ 500m point waveform)

Straight line interpolation or Sin X/X interpolation (2 or 5 points) (≦ 500m point waveform)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Oscilloscopes Products

Other products of Teledyne LeCroy

Reviews shown here are reviews of companies.


View more products of Teledyne LeCroy

About Company Handling This Product

Response Rate

100.0%


Response Time

25.8hrs

Company Overview

Teledyne LeCroy was founded in 1964 and is headquartered in Chestnut Ridge, New York, with sales, service, and...

See More

  • United States of America

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree