Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD-8038HD
Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD-Teledyne LeCroy

Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD
Teledyne LeCroy


About This Product

■ Characteristics ・ 15.6 inch/touch screen 1,900 × 1,080 ・ Analog 8 channel input ・ Compatible with Probus Prove/Interface for teledine recreali probes ・ Tablet -like intuition operation with OneTouch Maui ・ Q-SCAPE, multi/tab display ・ Up to 5g points waveform capture memory ・ HD4096 High -resolution technologies are always 12 -bit ・ The button and knob that glow in the color according to the display color of the waveform ・ Currently cursor operation and set value change without opening the menu ・ Mixed signal function on 16 channels digital/port ・ 6 USB3.1 ports (front 2, horizontal 4) ・ HDMI external display port, 4K (4,096 × 2,304) external monitor/support ・ Removable SSD (standard) ・ 16 channels displayed when 2 units synchronized with OSCillosync ・ Input/output of synchronization with external devices/clock ・ High -speed remote control with USB3.1 (USBTMC) ■ HD4096 Technology Low noise & always 12 bits Teledine/Recroy's 12 -bit high -resolution oscilloscope provides unusual measurement capacity that does not compromise using its own HD4096 technology. High -speed sampling, 12 -bit high resolution AD converter. Input amplorer with high SN ratio. (Up to 2 GHz) Low noise architecture. Once, if you experience the high -precision and high -definition HD4096 technology, you will not be able to return to the 8 -bit oscilloscope again. HD4096 technology provides unparalleled reliability and measurement, regardless of general design, debugging, high -precision sensor, power electronics, car electronics, mechatronics, etc. ■ Clear and clean waveform Compared to the waveform captured by the conventional 8 -bit oscilloscope, the waveform captured by HD4096 12 -bit/technology is overwhelmingly clear, clean and more accurate. HD4096 If you look at the waveforms captured by technology, you will no longer be able to return to 8 -bit oscilloscope.

  • Product

    Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD




*Please note that we may not be able to accommodate sample requests.

4 Models of Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Analog bandwidth@1Ω (-3db) Analog bandwidth@50Ω (-3db) Average number Capture -Analog Channel sampling speed Channel between isolation Clock accuracy DC gain accuracy (DC accuracy gain component) Descue range between channels Frequency band restriction Horizontal axis -analog channel time base Input channel Input coupling Input impey dance Maximum input voltage Number of valid bits (ENOB) Offset accuracy Offset range Rescaling Rising time (10-90%, 50Ω-warranty value) Rising time (20-80%, 50Ω-representative value) Sampling Clock Jitter See external time base (input) See external time base (output) Segment interval Standard memory long option (4ch / 2ch) Time base range Vertical decomposition ability Vertical noise floor 1mv/Div ~ 1V/Div interpolation sensitivity
Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD-Part Number-8038HD

8038HD

Available upon quote 350MHz 350MHz Additional average: Up to 1 million sweep, continuous average: Up to 1 million sweep (≦ 500m point waveform) 10Gs/S (Enhanced Sampling) 70 DB @ DC ~ 200 MHz, 60 DB @ 200 ~ 350 MHz ± 1 PPM calibration+ 1 ppm/year Full scale ± 0.5%, offset 0V ± 9 × Time/Div, up to 100ms, each channel 20 MHz, 200 MHz The internal time base is common to 8 input 8 1 mΩ: AC, DC, GND; 50 ω: DC, GND 50 Ω: ± 2.0%; 1 mΩ: 19 PF, 10 mΩ: 10 PF 50 Ω: 5 VRMS, ± 10V peak, 1 mΩ: 400 V Max (DC + Peak AC ≤ 10 kHz) 8.9 ± (0.5% of offset value + 0.5% + 1 MV of full scale) 50 Ω: 1 MV ~ 4.95 MV: ± 1.6 V; 5 MV ~ 9.9 MV: ± 4 V, 10 MV ~ 19.8 MV: ± 8 V; 20 MV ~ 1 V: ± 10 V Length: meters, inch, feet, yard, mile/mass: gram, slag/temperature: Hana, Kelvin/angle: Radian, ARCDEGR, minute, cycle, cycle, turn, turn 1NS 750ps Capture time range up to 10US: 80 FSRMS (see internal time base), 10ms capture time range: 150 FSRMS (see internal time base) 10MHz ± 25ppm (0 ~ 10dbm, 50Ω input) 10MHz 5.0dbm ± 2.5dbm, synchronization with the time base of the oscilloscope (internal or external reference) 1.5 μs Standard: 50m points/100m points/200m points (65,535 segments) 100 ps/div ~ 5 ks/div (up to 10 ks/div for 500MPT memo application, up to 25 ks/div for 1000Mpt memo application 12 Bit Resolution Improvement Operation (ERES) Up to 15 bits when used 95μV ~ 2.95mv Straight line interpolation or Sin X/X interpolation (2 or 5 points) (≦ 500m point waveform) 50 Ω: 1 MV -1 V/DIV (consecutive variable variable settings), Fully Variable; 1 MΩ: 1 MV -10 V/DIV (consecutive variable settings)
Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD-Part Number-8058HD

8058HD

Available upon quote 500MHz 500MHz Additional average: Up to 1 million sweep, continuous average: Up to 1 million sweep (≦ 500m point waveform) 10Gs/S (Enhanced Sampling) 70 DB @ DC ~ 200 MHz, 60 DB @ 200 ~ 500 MHz ± 1 PPM calibration+ 1 ppm/year Full scale ± 0.5%, offset 0V ± 9 × Time/Div, up to 100ms, each channel 20 MHz, 200 MHz, 350 MHz The internal time base is common to 8 input 8 1 mΩ: AC, DC, GND; 50 ω: DC, GND 50 Ω: ± 2.0%; 1 mΩ: 19 PF, 10 mΩ: 10 PF 50 Ω: 5 VRMS, ± 10V peak, 1 mΩ: 400 V Max (DC + Peak AC ≤ 10 kHz) 8.8 ± (0.5% of offset value + 0.5% + 1 MV of full scale) 50 Ω: 1 MV ~ 4.95 MV: ± 1.6 V; 5 MV ~ 9.9 MV: ± 4 V, 10 MV ~ 19.8 MV: ± 8 V; 20 MV ~ 1 V: ± 10 V Length: meters, inch, feet, yard, mile/mass: gram, slag/temperature: Hana, Kelvin/angle: Radian, ARCDEGR, minute, cycle, cycle, turn, turn 700ps 525ps Capture time range up to 10US: 80 FSRMS (see internal time base), 10ms capture time range: 150 FSRMS (see internal time base) 10MHz ± 25ppm (0 ~ 10dbm, 50Ω input) 10MHz 5.0dbm ± 2.5dbm, synchronization with the time base of the oscilloscope (internal or external reference) 1.5 μs Standard: 50m points/100m points/200m points (65,535 segments) 100 ps/div ~ 5 ks/div (up to 10 ks/div for 500MPT memo application, up to 25 ks/div for 1000Mpt memo application 12 Bit Resolution Improvement Operation (ERES) Up to 15 bits when used 100μV ~ 3.15mv Straight line interpolation or Sin X/X interpolation (2 or 5 points) (≦ 500m point waveform) 50 Ω: 1 MV -1 V/DIV (consecutive variable variable settings), Fully Variable; 1 MΩ: 1 MV -10 V/DIV (consecutive variable settings)
Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD-Part Number-8108HD

8108HD

Available upon quote 500MHz 1GHz Additional average: Up to 1 million sweep, continuous average: Up to 1 million sweep (≦ 500m point waveform) 10Gs/S (Enhanced Sampling) 70 DB @ DC ~ 200 MHz, 60 DB @ 200 ~ 500 MHz, 50 DB @ 500 ~ 1 GHz ± 1 PPM calibration+ 1 ppm/year Full scale ± 0.5%, offset 0V ± 9 × Time/Div, up to 100ms, each channel 20 MHz, 200 MHz, 350 MHz, 500MHz The internal time base is common to 8 input 8 1 mΩ: AC, DC, GND; 50 ω: DC, GND 50 Ω: ± 2.0%; 1 mΩ: 19 PF, 10 mΩ: 10 PF 50 Ω: 5 VRMS, ± 10V peak, 1 mΩ: 400 V Max (DC + Peak AC ≤ 10 kHz) 8.6 ± (0.5% of offset value + 0.5% + 1 MV of full scale) 50 Ω: 1 MV ~ 4.95 MV: ± 1.6 V; 5 MV ~ 9.9 MV: ± 4 V, 10 MV ~ 19.8 MV: ± 8 V; 20 MV ~ 1 V: ± 10 V Length: meters, inch, feet, yard, mile/mass: gram, slag/temperature: Hana, Kelvin/angle: Radian, ARCDEGR, minute, cycle, cycle, turn, turn 400ps 300ps Capture time range up to 10US: 80 FSRMS (see internal time base), 10ms capture time range: 150 FSRMS (see internal time base) 10MHz ± 25ppm (0 ~ 10dbm, 50Ω input) 10MHz 5.0dbm ± 2.5dbm, synchronization with the time base of the oscilloscope (internal or external reference) 1.5 μs Standard: 50m points/100m points/200m points (65,535 segments) 100 ps/div ~ 5 ks/div (up to 10 ks/div for 500MPT memo application, up to 25 ks/div for 1000Mpt memo application 12 Bit Resolution Improvement Operation (ERES) Up to 15 bits when used 130 μV ~ 4.00mv Straight line interpolation or Sin X/X interpolation (2 or 5 points) (≦ 500m point waveform) 50 Ω: 1 MV -1 V/DIV (consecutive variable variable settings), Fully Variable; 1 MΩ: 1 MV -10 V/DIV (consecutive variable settings)
Always 12 bits, up to 16ch high -resolution oscilloscope WAVERUNNER 8000HD-Part Number-8208HD

8208HD

Available upon quote 500MHz 2GHz Additional average: Up to 1 million sweep, continuous average: Up to 1 million sweep (≦ 500m point waveform) 10Gs/S (Enhanced Sampling) 70 DB @ DC ~ 200 MHz, 60 DB @ 200 ~ 500 MHz, 50 DB @ 500 ~ 1 GHz, 40 DB @ 1GHz ~ 2GHz ± 1 PPM calibration+ 1 ppm/year Full scale ± 0.5%, offset 0V ± 9 × Time/Div, up to 100ms, each channel 20 MHz, 200 MHz, 350 MHz, 500MHz, 1GHz The internal time base is common to 8 input 8 1 mΩ: AC, DC, GND; 50 ω: DC, GND 50 Ω: ± 2.0%; 1 mΩ: 19 PF, 10 mΩ: 10 PF 50 Ω: 5 VRMS, ± 10V peak, 1 mΩ: 400 V Max (DC + Peak AC ≤ 10 kHz) 8.4 ± (0.5% of offset value + 0.5% + 1 MV of full scale) 50 Ω: 1 MV ~ 4.95 MV: ± 1.6 V; 5 MV ~ 9.9 MV: ± 4 V, 10 MV ~ 19.8 MV: ± 8 V; 20 MV ~ 1 V: ± 10 V Length: meters, inch, feet, yard, mile/mass: gram, slag/temperature: Hana, Kelvin/angle: Radian, ARCDEGR, minute, cycle, cycle, turn, turn 235ps 176ps Capture time range up to 10US: 80 FSRMS (see internal time base), 10ms capture time range: 150 FSRMS (see internal time base) 10MHz ± 25ppm (0 ~ 10dbm, 50Ω input) 10MHz 5.0dbm ± 2.5dbm, synchronization with the time base of the oscilloscope (internal or external reference) 1.5 μs Standard: 50m points/100m points/200m points (65,535 segments) 100 ps/div ~ 5 ks/div (up to 10 ks/div for 500MPT memo application, up to 25 ks/div for 1000Mpt memo application 12 Bit Resolution Improvement Operation (ERES) Up to 15 bits when used 170μV ~ 5.20mv Straight line interpolation or Sin X/X interpolation (2 or 5 points) (≦ 500m point waveform) 50 Ω: 1 MV -1 V/DIV (consecutive variable variable settings), Fully Variable; 1 MΩ: 1 MV -10 V/DIV (consecutive variable settings)

Click on the part number for more information about each product

Customers who viewed this product also viewed