All Categories

History

Compact size -free CCD light device ISOPLANE 81-BRX
Compact size -free CCD light device ISOPLANE 81-Teledyne LeCroy

Compact size -free CCD light device ISOPLANE 81
Teledyne LeCroy

Teledyne LeCroy's Response Status

Response Rate

100.0%

Response Time

25.8hours

Relatively Fast Response


About This Product

All areas of CCD elements can be measured without aberration. Ideal for imaging and microscope measurement. Optional fiber, assembly optical block, excitement laser can easily measure Raman and PL.

■ Characteristics

・ CCD spectroscopy integrated compact size Installation adjustment required, 1,024x256 element (13x13 μm pixel size), back irradiation type, electron cooling ・ Unrecorded spectroscopy ·Low price ・ Improved signal strength and decomposition (FWHM) by unrivaled optical system ・ High sensitivity QE ・ Compact size ·application ・ Raman measurement can be easily measured with various options, ideal for microscopic light

  • Product

    Compact size -free CCD light device ISOPLANE 81

Share this product


300+ people viewing

Last viewed: 2 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

2 Models of Compact size -free CCD light device ISOPLANE 81

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Sensor type Sensor Benefit Sensor format Cooling temperature Reading noise Dark Current* Stray light ** Shift speed Spectral rate Spectral rate (Burst mode) Non -linearity gain Focal length Brightness resolution Wavelength range Spatial resolution Grating Non -point aberration/frame aberration slit Wavelength accuracy Wavelength reproducibility software operating system Data interface I/O Signals Operating temperature Certification size weight
Compact size -free CCD light device ISOPLANE 81-Part Number-BRX

BRX

Available upon quote

TPI Proprietary, Back-Illuminated, DeepdePLETION, Frame-Transfer CCD with Excelon ™ Technology and UV

Enhanced NIR RESPONSE WITH> 97% PEAK QE

1,024 x 256 (1,024 x 512 INCLUDING Frame-Transfer Storage Area)

-55 ℃ Guaranteed; -60 ℃ Typical

4E-RMS@200kHz; 7e-RMS@1MHz; 20E-RMS@4.55MHz

3e-/pixel/sec

<10-4

5.6 µSec/Row to 35 µSec/Row (ProgramMable)

292 Spectra/Sec (FULL VERTICAL BIN)

> 10,000 SPECTRA/SEC (Spectral Kinetics Mode with 10 Rows Binned)

<1%@all adc Rates

1.5E-/Adu (HighGain); 3 E-/Adu (Lowgain); Available at all ADC Rates

80.8mm

f/4

0.13nm

Protected Silver Coating, 400-1,100nm

38.5lp/mm@50% Contrast over entire focal plane (NYQUIST LIMITED)

150g/mm Up to 4,320g/mm; User-Changeable, Rotatable, Single-Grating Turlet

ZERO All wavelengths, grating angles

Slit Width: 10 µm Up to 500µm; 3.3mm Tall; Interchangeable, Laser-Cut Slits

0.13nm

0.015nm

Lightfield®Scientific Imaging and Spectroscopy Software

Microsoft® Windows® 8 or 10

USB3.0 (3 m interface Cable Provided)

THREE MCX COAXIAL CONNECTORS: Two Trigger Out, One Trigger In; Built-in Programmable PulseNerator

+5 ° C to +30 ° C NON-CONDENSING

CE

26cm x18.0cm x21.0cm (11 "x 7" x 8 ")

8.84 kg (19.5 LBS)

Compact size -free CCD light device ISOPLANE 81-Part Number-BX

BX

Available upon quote

TPI Proprietary, Back-ILLUMINATED, Frametransfer CCD with Excelon ™ Technology
And UV Coating

ULTRALOW DARK CURRENT FOR LONG-EXPOSURE EXPERIMENTS

1,024 x 256 (1,024 x 512 INCLUDING Frame-Transfer Storage Area)

-55 ℃ Guaranteed; -60 ℃ Typical

4E-RMS@200kHz; 7e-RMS@1MHz; 20E-RMS@4.55MHz

0.03e-/pixel/sec

<10-4

15.2 µSec/Row to 95 µSec/Row (ProgramMable)

124 SPECTRA/SEC (FULL VERTICAL BIN)

> 5,000 Spectra/Sec (Spectral Kinetics Mode with 10 Rows Binned)

<1%@all adc Rates

1.5E-/Adu (HighGain); 3 E-/Adu (Lowgain); Available at all ADC Rates

80.8mm

f/4

0.13nm

Aluminum coating, 200-1,100nm

38.5lp/mm@50% Contrast over entire focal plane (NYQUIST LIMITED)

150g/mm Up to 4,320g/mm; User-Changeable, Rotatable, Single-Grating Turlet

ZERO All wavelengths, grating angles

Slit Width: 10 µm Up to 500µm; 3.3mm Tall; Interchangeable, Laser-Cut Slits

0.13nm

0.015nm

Lightfield®Scientific Imaging and Spectroscopy Software

Microsoft® Windows® 8 or 10

USB3.0 (3 m interface Cable Provided)

THREE MCX COAXIAL CONNECTORS: Two Trigger Out, One Trigger In; Built-in Programmable PulseNerator

+5 ° C to +30 ° C NON-CONDENSING

CE

26cm x18.0cm x21.0cm (11 "x 7" x 8 ")

8.84 kg (19.5 LBS)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Spectroscopes Products

Other products of Teledyne LeCroy

Reviews shown here are reviews of companies.


View more products of Teledyne LeCroy

About Company Handling This Product

Response Rate

100.0%


Response Time

25.8hrs

Company Overview

Teledyne LeCroy was founded in 1964 and is headquartered in Chestnut Ridge, New York, with sales, service, and...

See More

  • United States of America

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree