Q Switch solid laser TalonHandling Company
Spectra-PhysicsCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | wavelength | power | Repeated rate | pulse width | Energy stability between pulse | Beam characteristic space mode | M^2 | Polarization rate | Beam diameter, waist position | Beam dissipation (full -width) | Beam's asymmetry (circularity) | Bore City tolerance value | Beam -oriented stability | AC input | Warm -up time | Temperature range | Advanced | Humidity | Cooling water temperature | Flow of cooling water | Heat load (for water) | Total power consumption | Dimensions (laser) (length x width x height) | Weight (laser) | Dimensions (utility module) (length x width x height) | Weight (utility module) | Featuring option safety shutter | Internal power monitor | E-PULSE Pulse Energy Control |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Talon UV45 |
Available upon quote |
355nm |
> 30 w @ 100kHz |
0 ~ 500kHz |
<35ns @ 150kHz |
<2%RMS @150kHz |
TEM00 |
<1.2 |
100: 1 vertical |
3.5mm ± 10% |
<0.3mrad |
<1.1 (>> 90%) |
<1mm, <1mrad |
<± 25 µrad/℃ |
AC110/220 ± 10%V, 50 ~ 60Hz |
Less than 20 minutes from standby. Less than 40 minutes from the cold start |
The operating temperature is 18-35 ° C. -20-50 ℃ Non -operating |
0 to 2,000 meters operations. 0 ~ 12,000m (when not operating) |
8-95%, no condensation |
Stable to 20 ℃ ± 1 ° C and ± 0.2 ° C |
3.5 ~ 6.0 liter/minute, usually 40 PSI |
Less than 800 watts |
Less than 900 watts |
28 x 9 x 5 inches (711 x 229 x 127mm) |
45 pounds (20.5kg) |
498 x 482 x 88mm (19.6 x 19 x 3.5 inches) |
22 pounds (10kg) |
Field service is easy by installing external installation, and you can replace it by customers. |
Calibration is possible for external power meters |
Keep pulse energy, pulse width, and beam parameters constantly over a wide range of repetitions |
|
Talon UV30 |
Available upon quote |
355nm |
> 15 w @ 50kHz |
0 ~ 500kHz |
<25ns @ 100kHz |
<2%RMS @100kHz, representative value |
TEM00 |
<1.2 |
100: 1 vertical |
3.5mm ± 10% |
<0.3mrad |
<1.1 (>> 90%) |
<1mm, <1mrad |
<± 25 µrad/℃ |
AC110/220 ± 10%V, 50 ~ 60Hz |
Less than 20 minutes from standby. Less than 40 minutes from the cold start |
The operating temperature is 18-35 ° C. -20-50 ℃ Non -operating |
0 to 2,000 meters operations. 0 ~ 12,000m (when not operating) |
8-95%, no condensation |
Stable to 20 ℃ ± 1 ° C and ± 0.2 ° C |
Minimum 1.5 liters/minutes, usually 20 PSI |
Less than 350 watts |
Less than 400 watts |
25 x 6 x 4.5 inches (635 x 153 x 115mm) |
28 pounds (12.7kg) |
498 x 482 x 88mm (19.6 x 19 x 3.5 inches) |
22 pounds (10kg) |
Field service is easy by installing external installation, and you can replace it by customers. |
Calibration is possible for external power meters |
Keep pulse energy, pulse width, and beam parameters constantly over a wide range of repetitions |
|
Talon UV20 |
Available upon quote |
355nm |
> 10w @ 50kHz |
0 ~ 500kHz |
<25ns @ 100kHz |
<2%RMS @100kHz, representative value |
TEM00 |
<1.2 |
100: 1 vertical |
3.5mm ± 10% |
<0.3mrad |
<1.1 (>> 90%) |
<1mm, <1mrad |
<± 10 µrad/℃ |
AC110/220 ± 10%V, 50 ~ 60Hz |
Less than 20 minutes from standby. Less than 40 minutes from the cold start |
The operating temperature is 18-35 ° C. -20-50 ℃ Non -operating |
0 to 2,000 meters operations. 0 ~ 12,000m (when not operating) |
8-95%, no condensation |
Stable to 20 ℃ ± 1 ° C and ± 0.2 ° C |
Minimum 1.5 liters/minutes, usually 20 PSI |
Less than 350 watts |
Less than 400 watts |
25 x 6 x 4.5 inches (635 x 153 x 115mm) |
28 pounds (12.7kg) |
498 x 482 x 88mm (19.6 x 19 x 3.5 inches) |
22 pounds (10kg) |
Field service is easy by installing external installation, and you can replace it by customers. |
Calibration is possible for external power meters |
Keep pulse energy, pulse width, and beam parameters constantly over a wide range of repetitions |
|
Talon UV15 |
Available upon quote |
355nm |
> 15 w @ 50kHz |
0 ~ 500kHz |
<25ns @ 100kHz |
<2%RMS @100kHz, representative value |
TEM00 |
<1.2 |
100: 1 vertical |
1.0mm ± 10%5 |
<0.6mrad |
<1.1 (>> 90%) |
<1mm, <1mrad |
<± 10 µrad/℃ |
AC110/220 ± 10%V, 50 ~ 60Hz |
Less than 20 minutes from standby. Less than 40 minutes from the cold start |
The operating temperature is 18-35 ° C. -20-50 ℃ Non -operating |
0 to 2,000 meters operations. 0 ~ 12,000m (when not operating) |
8-95%, no condensation |
Stable to 20 ℃ ± 1 ° C and ± 0.2 ° C |
Minimum 1.5 liters/minutes, usually 20 PSI |
Less than 300 watts |
Less than 300 watts |
25 x 6 x 4.5 inches (635 x 153 x 115mm) |
28 pounds (12.7kg) |
498 x 482 x 88mm (19.6 x 19 x 3.5 inches) |
22 pounds (10kg) |
Field service is easy by installing external installation, and you can replace it by customers. |
Calibration is possible for external power meters |
Keep pulse energy, pulse width, and beam parameters constantly over a wide range of repetitions |
|
Talon UV12 |
Available upon quote |
355nm |
> 12 W @ 50kHz |
0 ~ 500kHz |
<25ns @ 100kHz |
<2%RMS @100kHz, representative value |
TEM00 |
<1.2 |
100: 1 vertical |
1.0mm ± 10% |
<0.6mrad |
<1.1 (>> 90%) |
<1mm, <1mrad |
<± 10 µrad/℃ |
AC110/220 ± 10%V, 50 ~ 60Hz |
Less than 20 minutes from standby. Less than 40 minutes from the cold start |
The operating temperature is 18-35 ° C. -20-50 ℃ Non -operating |
0 to 2,000 meters operations. 0 ~ 12,000m (when not operating) |
8-95%, no condensation |
Stable to 20 ℃ ± 1 ° C and ± 0.2 ° C |
Minimum 1.5 liters/minutes, usually 20 PSI |
Less than 300 watts |
Less than 300 watts |
25 x 6 x 4.5 inches (635 x 153 x 115mm) |
28 pounds (12.7kg) |
498 x 482 x 88mm (19.6 x 19 x 3.5 inches) |
22 pounds (10kg) |
Field service is easy by installing external installation, and you can replace it by customers. |
Calibration is possible for external power meters |
Keep pulse energy, pulse width, and beam parameters constantly over a wide range of repetitions |
|
Talon UV6 |
Available upon quote |
355nm |
> 6 w @ 50kHz |
0 ~ 500kHz |
<25ns @ 100kHz |
<2%RMS @50kHz, representative value |
TEM00 |
<1.2 |
100: 1 vertical |
1.0mm ± 10% |
<0.6mrad |
<1.1 (>> 90%) |
<1mm, <1mrad |
<± 10 µrad/℃ |
AC110/220 ± 10%V, 50 ~ 60Hz |
Less than 20 minutes from standby. Less than 40 minutes from the cold start |
The operating temperature is 18-35 ° C. -20-50 ℃ Non -operating |
0 to 2,000 meters operations. 0 ~ 12,000m (when not operating) |
8-95%, no condensation |
Stable to 20 ℃ ± 1 ° C and ± 0.2 ° C |
Minimum 1.5 liters/minutes, usually 20 PSI |
Less than 300 watts |
Less than 300 watts |
25 x 6 x 4.5 inches (635 x 153 x 115mm) |
28 pounds (12.7kg) |
498 x 482 x 88mm (19.6 x 19 x 3.5 inches) |
22 pounds (10kg) |
Field service is easy by installing external installation, and you can replace it by customers. |
Calibration is possible for external power meters |
Keep pulse energy, pulse width, and beam parameters constantly over a wide range of repetitions |
|
Talon GR20 |
Available upon quote |
532nm |
> 20 w @ 50kHz |
0 ~ 500kHz |
<25ns @ 100kHz |
<2%RMS @ 100kHz, representative value |
TEM00 |
<1.2 |
100: 1 vertical |
1.0mm ± 10% |
<0.9mrad |
<1.1 (>> 90%) |
<1mm, <1mrad |
<± 10 µrad/℃ |
AC110/220 ± 10%V, 50 ~ 60Hz |
Less than 20 minutes from standby. Less than 40 minutes from the cold start |
The operating temperature is 18-35 ° C. -20-50 ℃ Non -operating |
0 to 2,000 meters operations. 0 ~ 12,000m (when not operating) |
8-95%, no condensation |
Stable to 20 ℃ ± 1 ° C and ± 0.2 ° C |
Minimum 1.5 liters/minutes, usually 20 PSI |
Less than 300 watts |
Less than 300 watts |
25 x 6 x 4.5 inches (635 x 153 x 115mm) |
28 pounds (12.7kg) |
498 x 482 x 88mm (19.6 x 19 x 3.5 inches) |
22 pounds (10kg) |
Field service is easy by installing external installation, and you can replace it by customers. |
Calibration is possible for external power meters |
none |
|
Talon GR40 |
Available upon quote |
532nm |
> 20 w @ 50kHz |
0 ~ 500kHz |
<25ns @ 100kHz |
<2%RMS @ 100kHz, representative value |
TEM00 |
<1.2 |
100: 1 vertical |
1.0mm ± 10% |
<0.9mrad |
<1.1 (>> 90%) |
<1mm, <1mrad |
<± 25 µrad/℃ |
AC110/220 ± 10%V, 50 ~ 60Hz |
Less than 20 minutes from standby. Less than 40 minutes from the cold start |
The operating temperature is 18-35 ° C. -20-50 ℃ Non -operating |
0 to 2,000 meters operations. 0 ~ 12,000m (when not operating) |
8-95%, no condensation |
Stable to 20 ℃ ± 1 ° C and ± 0.2 ° C |
Minimum 1.5 liters/minutes, usually 20 PSI |
Less than 350 watts |
Less than 400 watts |
25 x 6 x 4.5 inches (635 x 153 x 115mm) |
28 pounds (12.7kg) |
498 x 482 x 88mm (19.6 x 19 x 3.5 inches) |
22 pounds (10kg) |
Field service is easy by installing external installation, and you can replace it by customers. |
Calibration is possible for external power meters |
none |
|
Talon GR70 |
Available upon quote |
532nm |
> 70 w @ 275kHz |
0 ~ 700kHz |
<43ns @ 550kHz |
Up to 550kHz <3%RMS |
TEM00 |
<1.2 |
100: 1 vertical |
2.0mm ± 10% |
<0.6mrad |
<1.1 (>> 90%) |
<1mm, <1mrad |
<± 25 µrad/℃ |
AC110/220 ± 10%V, 50 ~ 60Hz |
Less than 20 minutes from standby. Less than 40 minutes from the cold start |
The operating temperature is 18-35 ° C. -20-50 ℃ Non -operating |
0 to 2,000 meters operations. 0 ~ 12,000m (when not operating) |
8-95%, no condensation |
Stable to 20 ℃ ± 1 ° C and ± 0.2 ° C |
3.5 ~ 6.0 liter/minute, usually 40 PSI |
Less than 800 watts |
Less than 900 watts |
28 x 9 x 5 inches (711 x 229 x 127mm) |
45 pounds (20.5kg) |
none |
none |
Field service is easy by installing external installation, and you can replace it by customers. |
Calibration is possible for external power meters |
none |