Insulated Channel Data Logger MIDI LOGGER GL240 Series-GL240
Insulated Channel Data Logger MIDI LOGGER GL240 Series-Graphtech Co., Ltd.

Insulated Channel Data Logger MIDI LOGGER GL240 Series
Graphtech Co., Ltd.


About This Product

■ Wireless LAN compatible high -performance data logger GL240 series The GL240 is a 10 -channel -type data logger that supports all channels and multi -function inputs and can measure various phenomena such as voltage and temperature. By narrowing the number of channels, data is possible at a maximum of 10 ms. Wireless measurement is realized with optional wireless LAN units, and remote monitoring is possible. You can select "parent unit mode" and "child unit mode" according to your customer's application, and connect the PETIT LOGGER GL100 as a single child machine. ■ Insulation multi -function input All channel insulation input method is adopted and there is no need to pay attention to the wiring. In addition, it supports multi -function input and can measure various phenomena. ・ I want to measure the voltage Equipped with abundant range from 20MV to 100V ・ I want to measure the temperature Thermal electricity vs.: K, J, T, R, S, B, N, C (former W: WRE5-26) ・ I want to measure the current Prepare a shunt resistance of 250Ω as an option Equipped with a dedicated 1-5V range in the measurement range ・ I want to measure humidity Exclusive humidity sensor is prepared as an option, and sensor power supply is supplied from the main unit, and a dedicated humidity range is installed. ・ Equipped with digital I/O Digital I/O can be used by connecting the optional input cable. ・ Logic/pulse input (either 4 points) Logic: No voltage contacts (contact A, B contact, NO, NC), open collector, H.L judgment by voltage input Pulse: You can select for each channel from 3 modes (rotation speed, accumulation, instantaneous) ■ Wireless measurement with wireless LAN unit ・ Optional wireless LAN unit (B-568) Wireless LAN unit is installed, and wireless measurement is achieved with "parent unit mode" and "child unit mode" according to the application. ・ Remote monitoring is also possible Connect to the Internet, data confirmation and email reception on PCs and smart devices ・ Utilize GL100 as a slave unit One GL100 can be connected as a child aircraft ■ Supports the sampling speed of up to 10ms Data at a maximum of 10 ms can be recorded by narrowing the number of channels.

  • Product

    Insulated Channel Data Logger MIDI LOGGER GL240 Series

Share this product


470+ people viewing

Last viewed: 1 hour ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

2 Models of Insulated Channel Data Logger MIDI LOGGER GL240 Series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) AC adapter Alarm judgment type Battery pack Built -in memory DC input External dimensions (W × D × H) (approx.) External memory slot Mass (weight) (approx.) Maximum number of pulse input Measuring mode Memory content Number of analog input CH PC I/F Repeat trigger Sampling cycle Time / Div Trigger setting Trigger type Vibration resistance input output power consumption usage environment
Insulated Channel Data Logger MIDI LOGGER GL240 Series-Part Number-GL240

GL240

$ 780.00〜 AC100-240V / 50-60Hz Analog judgment: Standing up (↑), falling down (↓), within the range, outside the range, logic judgment: Pattern, pulse judgment: Standing up (↑), falling (↓), within the range DC7.2V (2,900mAh) (battery pack option) SD1 about 8GB (built -in fixed) DC8.5-24V 188 x 117 x 42mm SD2 slot, SD memory card: SDHC compatible, up to about 32GB memory can be used 500g (not included AC adapter, battery) Maximum input frequency: 50kHz, maximum count: 50kc/sampling (16bit counter) Rotation mode/accumulation mode/instant mode Setting conditions, measurement data, screen copy of the main unit 10ch USB2.0 (high speed), wireless LAN (when optional) OFF / ON 10ms to 1h (10ms to 50ms is voltage only, CH mathematical limit), external 1S to 24h Start: OFF, Level, Alarm, External, Time, Day, Regular time, Stop: OFF / Level / Alarm / External / Time / Day Start: Start data recording due to trigger, stop: Stop data due to trigger. Automotive parts 1 type 1 type A equivalent Trigger input (1ch) or external sampling input (1ch), logic input 4ch or pulse input (4ch), input voltage range: 0 to+24V (single -line contact input), input signal: non -voltage contact (A contact point, B contact point , NO, NC), open collector, voltage input Alarm output (4ch), output format: Open collector output (5V pull -up resistance 10kΩ) 36va or less (using AC adapter, when ON LCD, when charging battery pack, AC100V) 0-45 ° C, 5-85 % RH (0 to 40 ° C during battery driving/15 to 35 ° C for charging)
Insulated Channel Data Logger MIDI LOGGER GL240 Series-Part Number-GL240-SD

GL240-SD

$ 780.00〜 AC100-240V / 50-60Hz Analog judgment: Standing up (↑), falling down (↓), within the range, outside the range, logic judgment: Pattern, pulse judgment: Standing up (↑), falling (↓), within the range DC7.2V (2,900mAh) (battery pack option) SD1 Slot Approximately 4GB (SD memory card included, can be taken out from slot) DC8.5-24V 188 x 117 x 42mm SD2 Slot SD Memory Card: SDHC compatible, up to about 32GB memory can be used 500g (not included AC adapter, battery) Maximum input frequency: 50kHz, maximum count: 50kc/sampling (16bit counter) Rotation mode/accumulation mode/instant mode Setting conditions, measurement data, screen copy of the main unit 10ch USB2.0 (high speed), wireless LAN (when optional) OFF / ON 10ms to 1h (10ms to 50ms is voltage only, CH mathematical limit), external 1S to 24h Start: OFF, Level, Alarm, External, Time, Day, Regular time, Stop: OFF / Level / Alarm / External / Time / Day Start: Start data recording due to trigger, stop: Stop data due to trigger. Automotive parts 1 type 1 type A equivalent Trigger input (1ch) or external sampling input (1ch), logic input 4ch or pulse input (4ch), input voltage range: 0 to+24V (single -line contact input), input signal: non -voltage contact (A contact point, B contact point , NO, NC), open collector, voltage input Alarm output (4ch), output format: Open collector output (5V pull -up resistance 10kΩ) 36va or less (using AC adapter, when ON LCD, when charging battery pack, AC100V) 0-45 ° C, 5-85 % RH (0 to 40 ° C during battery driving/15 to 35 ° C for charging)

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Graphtech Co., Ltd.


View more products of Graphtech Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree