Time Counter Hearmeter Electrometer 891 Series-0 891 213
Time Counter Hearmeter Electrometer 891 Series-Fourty ICG Japan Co., Ltd.

Time Counter Hearmeter Electrometer 891 Series
Fourty ICG Japan Co., Ltd.


About This Product

■ Features ・ Compact size ・ There is no reset function, so you can count the total time ・ We have a variety of power supply voltage types, so you can select according to the usage environment. ・ Easy installation by mounting device ・ By combining with the optional frame, it can be used as your favorite panel shape. ・ The operating status can be visible (the right end of the arrow rotates downward during the power) * Use of seals is not required. It is an option when you want to increase waterproof properties.

  • Product

    Time Counter Hearmeter Electrometer 891 Series




*Please note that we may not be able to accommodate sample requests.

9 Models of Time Counter Hearmeter Electrometer 891 Series

Items marked with have different values ​​depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Electrical connection General structure High letters IEC 068-2-27) Mounting direction Mounting method Operating temperature limit Power supply voltage (AC type) Power supply voltage (DC type) Power supply voltage and operating range ① Protection grade (IEC 144) Save temperature range Units of measurement time Vibration resistance (IEC 068-2-6) certification display frequency option power consumption reset size weight
Time Counter Hearmeter Electrometer 891 Series-Part Number-0 891 213

0 891 213

Available upon quote Screw terminals (can also be used as No.250 type Faston terminal) Compatible with DIN VDE Part 1, protection grade II, pollution level 2, over -voltage category II 5mm (character width 2mm) 800m/s^2 (6ms) The number wheel axis maintains horizontal to the ground (displayed orientation) Mounting equipment usage (attached to the main unit) -10 ℃ ~+50 ℃ AC 100V - Total difference ± 10% IP40 (front), IP66 (when using seal, front) IP20 (screw terminal), IP00 (No.250 Faston terminal) -20 ℃ ~+70 ℃ 0.01 hours (36 seconds) 30 m/s^2 (10 ~ 500 Hz) UL E 130453 (m), CSA (AC type only) 7 digits, 0 to 9999.99H 50Hz Frame / seal 0.3va none 24 x 48 mm (panel cut dimensions: 22.2 x 45 mm) Approximately 50g
Time Counter Hearmeter Electrometer 891 Series-Part Number-0 891 203

0 891 203

Available upon quote Screw terminals (can also be used as No.250 type Faston terminal) Compatible with DIN VDE Part 1, protection grade II, pollution level 2, over -voltage category II 5mm (character width 2mm) 800m/s^2 (6ms) The number wheel axis maintains horizontal to the ground (displayed orientation) Mounting equipment usage (attached to the main unit) -10 ℃ ~+50 ℃ AC 115V - Total difference ± 10% IP40 (front), IP66 (when using seal, front) IP20 (screw terminal), IP00 (No.250 Faston terminal) -20 ℃ ~+70 ℃ 0.01 hours (36 seconds) 30 m/s^2 (10 ~ 500 Hz) UL E 130453 (m), CSA (AC type only) 7 digits, 0 to 9999.99H 50Hz Frame / seal 0.6va none 24 x 48 mm (panel cut dimensions: 22.2 x 45 mm) Approximately 50g
Time Counter Hearmeter Electrometer 891 Series-Part Number-0 891 215

0 891 215

Available upon quote Screw terminals (can also be used as No.250 type Faston terminal) Compatible with DIN VDE Part 1, protection grade II, pollution level 2, over -voltage category II 5mm (character width 2mm) 800m/s^2 (6ms) The number wheel axis maintains horizontal to the ground (displayed orientation) Mounting equipment usage (attached to the main unit) -10 ℃ ~+50 ℃ AC 200V - Total difference ± 10% IP40 (front), IP66 (when using seal, front) IP20 (screw terminal), IP00 (No.250 Faston terminal) -20 ℃ ~+70 ℃ 0.01 hours (36 seconds) 30 m/s^2 (10 ~ 500 Hz) UL E 130453 (m), CSA (AC type only) 7 digits, 0 to 9999.99H 50Hz Frame / seal 0.7va none 24 x 48 mm (panel cut dimensions: 22.2 x 45 mm) Approximately 50g
Time Counter Hearmeter Electrometer 891 Series-Part Number-0 891 211

0 891 211

Available upon quote Screw terminals (can also be used as No.250 type Faston terminal) Compatible with DIN VDE Part 1, protection grade II, pollution level 2, over -voltage category II 5mm (character width 2mm) 800m/s^2 (6ms) The number wheel axis maintains horizontal to the ground (displayed orientation) Mounting equipment usage (attached to the main unit) -10 ℃ ~+50 ℃ AC 230V - Total difference ± 15% IP40 (front), IP66 (when using seal, front) IP20 (screw terminal), IP00 (No.250 Faston terminal) -20 ℃ ~+70 ℃ 0.01 hours (36 seconds) 30 m/s^2 (10 ~ 500 Hz) UL E 130453 (m), CSA (AC type only) 7 digits, 0 to 9999.99H 50Hz Frame / seal 0.7va none 24 x 48 mm (panel cut dimensions: 22.2 x 45 mm) Approximately 50g
Time Counter Hearmeter Electrometer 891 Series-Part Number-0 891 214

0 891 214

Available upon quote Screw terminals (can also be used as No.250 type Faston terminal) Compatible with DIN VDE Part 1, protection grade II, pollution level 2, over -voltage category II 5mm (character width 2mm) 800m/s^2 (6ms) The number wheel axis maintains horizontal to the ground (displayed orientation) Mounting equipment usage (attached to the main unit) -10 ℃ ~+50 ℃ AC 100V - Total difference ± 10% IP40 (front), IP66 (when using seal, front) IP20 (screw terminal), IP00 (No.250 Faston terminal) -20 ℃ ~+70 ℃ 0.01 hours (36 seconds) 30 m/s^2 (10 ~ 500 Hz) UL E 130453 (m), CSA (AC type only) 7 digits, 0 to 9999.99H 60Hz Frame / seal 0.3va none 24 x 48 mm (panel cut dimensions: 22.2 x 45 mm) Approximately 50g
Time Counter Hearmeter Electrometer 891 Series-Part Number-0 891 204

0 891 204

Available upon quote Screw terminals (can also be used as No.250 type Faston terminal) Compatible with DIN VDE Part 1, protection grade II, pollution level 2, over -voltage category II 5mm (character width 2mm) 800m/s^2 (6ms) The number wheel axis maintains horizontal to the ground (displayed orientation) Mounting equipment usage (attached to the main unit) -10 ℃ ~+50 ℃ AC 115V - Total difference ± 10% IP40 (front), IP66 (when using seal, front) IP20 (screw terminal), IP00 (No.250 Faston terminal) -20 ℃ ~+70 ℃ 0.01 hours (36 seconds) 30 m/s^2 (10 ~ 500 Hz) UL E 130453 (m), CSA (AC type only) 7 digits, 0 to 9999.99H 60Hz Frame / seal 0.6va none 24 x 48 mm (panel cut dimensions: 22.2 x 45 mm) Approximately 50g
Time Counter Hearmeter Electrometer 891 Series-Part Number-0 891 216

0 891 216

Available upon quote Screw terminals (can also be used as No.250 type Faston terminal) Compatible with DIN VDE Part 1, protection grade II, pollution level 2, over -voltage category II 5mm (character width 2mm) 800m/s^2 (6ms) The number wheel axis maintains horizontal to the ground (displayed orientation) Mounting equipment usage (attached to the main unit) -10 ℃ ~+50 ℃ AC 200V - Total difference ± 10% IP40 (front), IP66 (when using seal, front) IP20 (screw terminal), IP00 (No.250 Faston terminal) -20 ℃ ~+70 ℃ 0.01 hours (36 seconds) 30 m/s^2 (10 ~ 500 Hz) UL E 130453 (m), CSA (AC type only) 7 digits, 0 to 9999.99H 60Hz Frame / seal 0.7va none 24 x 48 mm (panel cut dimensions: 22.2 x 45 mm) Approximately 50g
Time Counter Hearmeter Electrometer 891 Series-Part Number-0 891 206

0 891 206

Available upon quote Screw terminals (can also be used as No.250 type Faston terminal) Compatible with DIN VDE Part 1, protection grade II, pollution level 2, over -voltage category II 5mm (character width 2mm) 800m/s^2 (6ms) The number wheel axis maintains horizontal to the ground (displayed orientation) Mounting equipment usage (attached to the main unit) -10 ℃ ~+50 ℃ AC 230V - Total difference ± 15% IP40 (front), IP66 (when using seal, front) IP20 (screw terminal), IP00 (No.250 Faston terminal) -20 ℃ ~+70 ℃ 0.01 hours (36 seconds) 30 m/s^2 (10 ~ 500 Hz) UL E 130453 (m), CSA (AC type only) 7 digits, 0 to 9999.99H 60Hz Frame / seal 0.7va none 24 x 48 mm (panel cut dimensions: 22.2 x 45 mm) Approximately 50g
Time Counter Hearmeter Electrometer 891 Series-Part Number-0 891 331

0 891 331

Available upon quote Screw terminals (can also be used as No.250 type Faston terminal) Compatible with DIN VDE Part 1, protection grade II, pollution level 2, over -voltage category II 5mm (character width 2mm) 800m/s^2 (6ms) The number wheel axis maintains horizontal to the ground (displayed orientation) Mounting equipment usage (attached to the main unit) -10 ℃ ~+50 ℃ - DC 12-36V Total difference ± 10% IP40 (front), IP66 (when using seal, front) IP20 (screw terminal), IP00 (No.250 Faston terminal) -20 ℃ ~+70 ℃ 0.01 hours (36 seconds) 30 m/s^2 (10 ~ 500 Hz) UL E 130453 (m), CSA (AC type only) 7 digits, 0 to 9999.99H - Frame / seal 350MW none 24 x 48 mm (panel cut dimensions: 22.2 x 45 mm) Approximately 50g

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Fourty ICG Japan Co., Ltd.


View more products of Fourty ICG Japan Co., Ltd.

About Company Handling This Product

Fourty ICG Japan Co., Ltd.

  • Japan
  • Since 1974
  • 18,000 employees

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree