All Categories

History

Area monitor X-zone®5800-X-zone®5800
Area monitor X-zone®5800-Dräger

Area monitor X-zone®5800
Dräger

Dräger's Response Status

Response Rate

100.0%

Response Time

2.8hours

Very Fast Response


About This Product

■Features

State-of-the-art area monitoring – Dräger X-zone® 5800 can be used to measure up to 6 gases in combination with gas detectors Dräger X-am® 5000, 5100 and 5600. The built-in pump and continuous power supply capability for use in explosive zone 0 expands the range of applications for mobile gas detection technology.

■Area monitor

​・Measure up to 6 gases in combination with Dräger X-am® 5000, 5100, 5600 ・Interconnect up to 25 devices and monitor a wide area - Continuous power supply option for use in explosive hazardous areas (Zone 0)

■Innovative area monitoring

Together with Dräger's personal gas detectors X-am5000, 5100 and 5600, the Dräger X-zone 5800 forms a versatile and innovative area monitoring device. In addition to personal portable gas detection alarms worn by workers, these area monitors are placed in areas where gas hazards are expected, resulting in a patented combination that provides a high degree of safety.

■Easy to understand warning

Even from a distance, the green LED ring lights up to let you know that there are no toxic or flammable gases in the air. When a dangerous gas is detected, the LED color changes from green to red, clearly indicating the danger at a glance. Additionally, it will issue an evacuation warning with a loud, audible sound. The gas inlet of the Dräger X-zone 5800 is located in such a way that gas can be taken in from any side of the Dräger

  • Product

    Area monitor X-zone®5800

Share this product


50+ people viewing

Last viewed: 23 minutes ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Area monitor X-zone®5800

Image Part Number Price (excluding tax) Weight Certification Domestic explosion proof certification Certification IECEx Environmental conditions Wireless transfer Wireless authentication Dimensions width x height x depth Operating time Charging time Protection class Life signal operation display Pump operation Alarm output
Area monitor X-zone®5800-Part Number-X-zone®5800

X-zone®5800

Available upon quote

10kg (24Ah battery)

・I M1 Ex ia I Ma
・Ex ia IIC T4 Ga

・Ex ia I Ma
・Ex ia IIC T4 Ga

・Temperature -20℃~+50℃
・Atmospheric pressure 700~1,300hPa
・Humidity 10~95% r.h.

・Worldwide license free ISM frequency
·digital
・Communication distance of approximately 30 to 50 meters (depending on the surrounding environment)

・920MHz (for Japanese market)
・915MHz (USA, Canada, Singapore, Australia)
・433MHz (Russia, Malaysia)

・490x300x300mm
・20x12x12 inches

・About 120 hours (when using 24Ah battery)
・Depends on the type of installed sensor and lamp lighting settings

・About 14 hours
・Power supply External 100~240V charger (worldwide) / Inductive wire charger

IP67

・Green status display lamp (360°)
・Illumination ring (LED)

Maximum hose length 45m, 30m (for zone 0)

・Alarm terminal (6 poles, potential free for safety circuits, 20V or less, 0.25A or less)
・0.15A constant current resistive load

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Area Sensors Products

Other products of Dräger

Reviews shown here are reviews of companies.


View more products of Dräger

About Company Handling This Product

Response Rate

100.0%


Response Time

2.8hrs

Company Overview

Dräger, established in 1889, and headquartered in Lübeck, Germany, is a manufacturer and supplier of advanced ...

See More

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree