Area monitor X-zone®5800Handling Company
DrägerCategories
Product Image | Part Number | Price (excluding tax) | Alarm output | Certification Domestic explosion proof certification | Certification IECEx | Charging time | Dimensions width x height x depth | Environmental conditions | Life signal operation display | Operating time | Protection class | Pump operation | Weight | Wireless authentication | Wireless transfer |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
X-zone®5800 |
Available upon quote |
・Alarm terminal (6 poles, potential free for safety circuits, 20V or less, 0.25A or less) ・0.15A constant current resistive load |
・I M1 Ex ia I Ma ・Ex ia IIC T4 Ga |
・Ex ia I Ma ・Ex ia IIC T4 Ga |
・About 14 hours ・Power supply External 100~240V charger (worldwide) / Inductive wire charger |
・490x300x300mm ・20x12x12 inches |
・Temperature -20℃~+50℃ ・Atmospheric pressure 700~1,300hPa ・Humidity 10~95% r.h. |
・Green status display lamp (360°) ・Illumination ring (LED) |
・About 120 hours (when using 24Ah battery) ・Depends on the type of installed sensor and lamp lighting settings |
IP67 | Maximum hose length 45m, 30m (for zone 0) | 10kg (24Ah battery) |
・920MHz (for Japanese market) ・915MHz (USA, Canada, Singapore, Australia) ・433MHz (Russia, Malaysia) |
・Worldwide license free ISM frequency ·digital ・Communication distance of approximately 30 to 50 meters (depending on the surrounding environment) |