Product
Wireless gas detector for toxic gases Polytron6100 EC WLHandling Company
DrägerCategories
Product Image | Part Number | Price (excluding tax) | Certification ATEX IECEx | Certification CE Directive | Certification Functional safety standards | Communication Measured value transmission Processing interface protocol | Communication range | Communication type | Communications Bluetooth® for operations and services | Electrical specifications Battery life | Electrical specifications Battery type | Electrical specifications Operating voltage | Electrical specifications Wired power supply | Housing Battery pack weight | Housing Transmitter weight | Housing cable gland | Housing dimensions | Housing material | Housing protection class | Target gas and measurement range | Usage environment Humidity | Usage environment Pressure | Usage environment Temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Polytron6100 EC WL |
Available upon quote |
・I M1/II 1GD Ex ia I Ma ・Ex ia IIC T4 Ga ・Ex ia IIIC T135 ℃ Da ・-40℃≤Ta≤+65℃ |
・ATEX Directive 2014/34/EU ・RED Directive 2014/53/EU ・RoHS Directive 2011/65/EU |
SIL2 | ISA100 WirelessTM or WirelessHART® | 500m in an unrestricted area | 2.4GHz ISM band industrial radio IEEE802.15.4 | Range 15m | Up to 2 years depending on operating conditions | Lithium thionyl chloride battery (battery pack, D cell type 4 pieces) | 14V~30V |
・2-core shielded cable ・24-12AWG/0.2-2.5mm² |
Approximately 0.5kg | Approximately 3.2kg | M25x1.5 | 320x150x170mm (including 2dBi antenna) | Stainless steel 316 | IP66/67 | Toxic gases and oxygen, see sensor data sheet. Compatible with all Dräger Sensors. |
・0~100%R.H ・No condensation |
700~1,300hPa | -40~+65℃ |