Automatic control package Il -free compressor DPF/DPFM for optimal stop pressure
A & C Service Co., Ltd.
About This Product
■ ECO mode
Energy saving is to be monitored by monitoring the usage of air compressors and automatically controlling the optimal stop pressure.
■ New design
The operating unit has been changed to a new design to improve operability and visibility.
■ Improvement of ease of use
・ The built -in air tank volume has been increased to 35L (conventional machine: 20L).
-The fixing of the door has been changed from a latch type to magnet catch, and the operability of the door opening and closing has been improved.
・ Installation area has been reduced (reduced by about 4 % compared to the conventional machine).
-The air tank is used in combination with a drain sucking type and a plating steel plate to make it difficult to clog the drain tube due to rust.
・ The duct is easier to work on with the upper exhaust structure.
■ Wide expandability
External input and output terminals are standard equipment.
■ Exciting air volume up
・ The cooling fins of the cylinder cover have been enhanced with high conductivity aluminum alloy, the area that touches the outside air has been enhanced, and the cooling effect has been enhanced.
・ Using a piston ring with a special cut in the joint, the seal has improved.
・ Improved the suction valve plate and improved inhalation efficiency.
■ High pressure of pressure used
The maximum pressure is 0.93 MPA, which supports more diverse applications. (5.5kW or less)
■ Improvement of reliability
・ The heat -cut piston pin, which is not easy to convey heat by forming insulation, suppresses the rise in needle bearing temperature.
・ The valve sheet is turned into an all -stainless steel, reduced trouble due to rust.
・ The piston ring is made of new resin and the wear resistance has been improved.
・ Digital display that is easy to confirm the pressure display and operation time.
・ Equipped with a durable durability in the fully closed fan.
■ Realization of a clean environment
Because it is oil -free, it does not require everyday oil management, and it is easy to process because it does not contain oil in the emission drain. (Oils sucked by the surrounding environment are included, but they are included.)
■ Saving maintenance
・ The overhaul is 10,000 hours and 500 hours ago, the maintenance warning lamp turned on.
・ The pressure display is notified while blinking alternately with the overhaul time. 1.5 to 3.7kW is 8,000 hours of maintenance cycle.
-Equipped with remote control terminals for remote control.
・ Equipped with top runner motor
-
-
Product
Automatic control package Il -free compressor DPF/DPFM for optimal stop pressure