All Categories
History
Relatively Fast Response
Product
Airtightness inspection equipment for small electronic components Bombing/Gross/Fine leak test system MSX-7000 series MSX-7000-00Handling Company
FUKUDA CO., LTD.Categories
Usage Scenarios
Electronics & Electrical UseImage | Part Number | Price (excluding tax) | Power supply voltage/power consumption | Mass | Display | Pneumatic source | Inspection target size (mm) | External dimensions (mm) *Excluding signal tower and LCD panel | Discrimination level (Pa・m3/s) | Processing speed | Usage temperature and humidity range | Helium source nitrogen source | Helium source/nitrogen source | Barcode reader | He calibrator |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
MSX-7000-00 |
Available upon quote |
AC200V±10% three-phase 50/60Hz・4kVA |
Approximately 1,500kg |
Touch panel 10.4 inch |
Air pressure source: 0.5MPa or higher Please use clean, dry air that does not fluctuate. |
1.0×0.8, 1.2×1.0 |
W1,800×D1,400×H1,800 |
Gross leak: 2×10^-7Pa・m3/s (equivalent standard leak) |
12ch1.0s/pcs (bombing 60min) |
0-40℃45~85%RH (no condensation) |
Connection Rc1/4 device External cylinder Pressure regulation to 0.6MPa Purity 99.99% or more |
Adjust the cylinder outside the device to 0.6MPa, purity 99.99% or more |
None |
None *Can only be selected if you already have it |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.