Earth Leakage Measurement Instrument / Logger I0R (I Zero R) Logger I0R700VHandling Company
Sanwa Electric Meter Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply | Battery life | Measurement circuit | Measurement mode | Dimensions/mass | External output | Input signal | AC voltage (ACV) accuracy | AC voltage (ACV) measurement range | Motor mode MΩ accuracy | Motor mode MΩ measurement range | Motor mode Ior accuracy | Motor mode Ior measurement range | Motor mode Io accuracy | Motor mode Io measurement range | Sample rate | I0R mode MΩ accuracy | I0R mode MΩ measurement range | I0R mode Ior accuracy | I0R mode Ior measurement range | I0R mode Io accuracy | I0R mode Io measurement range |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
I0R700V |
Available upon quote |
6 AA alkaline batteries (LR6), dedicated AC adapter (AD-I0R700) |
Continuous approximately 20 hours (alkaline battery) |
Single phase, three phase delta connection, three phase star connection |
I0R mode, motor mode |
H102×W179×D48mm/approx. 584g |
SD card, USB, alarm output |
Current: CT sensor (Φ40mm/Φ68mm/Φ110mm) |
± (1%+3) (When using CT sensor Φ40mm) |
0.0V~600.0V |
Not specified (calculated value) (when using CT sensor Φ40mm) |
0.00MΩ~99.99MΩ |
± (1%+40+Io*0.005) (When using CT sensor Φ40mm) |
0.000mA~99.999mA |
± (1%+40) (When using CT sensor Φ40mm) |
0.000mA~99.999mA |
Numerical part 1 time/sec |
Not specified (calculated value) (when using CT sensor Φ40mm) |
0.00MΩ~99.99MΩ |
± (1%+40+Io*0.005) (When using CT sensor Φ40mm) |
0.000mA~999.999mA |
± (1%+40) (When using CT sensor Φ40mm) |
0.000mA~999.999mA |