All Categories
History
Response Rate
100.0%
Response Time
53.8hours
Product
Insulation resistance meter (Megger) / Earth resistance meter (Earth tester) Digital insulation resistance meter (Megger) HG561HHandling Company
Sanwa Electric Meter Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply | Battery low warning | Insulation resistance (level meter) | LCD display (number of counts) | Automatic polarity display switching | Maximum power consumption | Dimensions/mass | Rated voltage measurement range | Rated measurement voltage (all 7 ranges) | Safety standards | Operating temperature/humidity | Operation method | Storage temperature/humidity | Operating environment conditions | AC detection method | Range switching | Sample rate | Over display | Auto power off | Ω Measuring range | Ω Maximum accuracy | Ω resolution | MΩ measurement range | MΩ maximum accuracy | MΩ resolution | IP rating | EMC directive, RoHS directive | ACV/DCV measurement range | ACV/DCV highest accuracy | ACV/DCV resolution |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
HG561H |
Available upon quote |
LR03 (AAA alkaline battery) 1.5V x 4 |
The battery mark lights up at approximately 4.3V or less. |
15/25/50V 5 levels (LED on or flashing) |
MΩ: 9.99/99.9/110 |
Only "-" is displayed when inputting a negative value |
Approximately 1,000 times |
H139×W91×D29mm/approx. 230g (battery included) |
15/25/50/100/125/250/500V |
15V/25V/50V |
IEC 61010 CAT.Ⅲ 300V, CAT.Ⅱ 600V |
90%RH or less at 0℃~40℃ |
Δ-Σ method |
-10℃~50℃, 90%RH or less, no condensation |
Altitude below 2,000m/Environmental pollution level II |
Average value method |
Auto |
Approximately 2 times/second |
OL" display and buzzer sound in numerical section |
Power off approximately 10 minutes after the last operation |
999.9/99.99k/999.9kΩ |
± (1.5%+7) |
0.1Ω |
15/25/50V 9.99M/21.0MΩ |
± (2%+5) |
0.01MΩ |
IP30 (with measurement probe attached) |
IEC61326 (EMC), EN50581 (RoHS) |
600V (AC/DC automatic discrimination) |
± (1.6%+7) |
0.1V |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
53.8hrs