All Categories

History

Top Runner Motor The Motor Neo100 Premium TFO-LK (LKK)-TFO-LK (LKK)
Top Runner Motor The Motor Neo100 Premium TFO-LK (LKK)-Fuji Electrode Industry Co., Ltd.

Top Runner Motor The Motor Neo100 Premium TFO-LK (LKK)
Fuji Electrode Industry Co., Ltd.

Fuji Electrode Industry Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

6.9hours

Fast Response


About This Product

A premium motor from the "The Motor" series that further pursues high efficiency and energy savings.

■ High efficiency and energy saving

It satisfies the Top Runner regulation efficiency value and achieves high economic efficiency through energy saving.

■Heat resistance class F is adopted as standard for all models.

Previously, heat-resistant class E was used for outputs of 3.7 kW or less, and heat-resistant class B was used for 5.5 to 22 kW (equivalent to 4 poles), but Top Runner Motors uses highly reliable "heat-resistant class F" materials for all models. I upgraded. The temperature rise value tends to be the same or lower than that of conventional motors, so when used in a package, the temperature inside the refrigerator will be better than before. Furthermore, although Top Runner Motor is intended for use in Japan, it will also serve as a base for use overseas in the future. Heat resistance class F is becoming the standard for overseas motor manufacturers, and we are also considering compliance with global standards.

■Same installation dimensions as standard motor

The mounting dimensions (frame number, shaft system, foot hole position, etc.) are the same as standard efficiency motors. For 3.7kW or less, the external dimensions are the same as standard efficiency motors, and for 5.5 to 15kW or less, the overall length is the same as standard efficiency motors.

■Space saving

Can also be mounted on top of the terminal box to save space on the side. You can also unify your inventory. We can also accommodate terminal box top structures over the entire output range. By mounting the terminal box on top, the width of the motor can be significantly reduced and floor space can be reduced. In addition, if you suddenly change the direction of the outlet, you can simply change the direction of the terminal box. Furthermore, if you use both the left-side and right-side terminal box installations, the terminal box top structure can accommodate both types by changing the exit direction.

■Protection structure IP55 adopted as standard (outdoor type)

IP55 is standard for outdoor specification motors in Europe and other countries. Until now, in Japan, IP44 structure was the standard, and IP55 was made to order. The Top Runner motor also follows the IP55 outdoor motor adopted in "The Motor Neo100" series, which aims to become a global standard. The adopted IP55 structure is a highly reliable structure based on our unique design concept.

  • Product

    Top Runner Motor The Motor Neo100 Premium TFO-LK (LKK)

Share this product


100+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Top Runner Motor The Motor Neo100 Premium TFO-LK (LKK)

Image Part Number Price (excluding tax) Voltage Atmosphere Applicable standards Connection method Heat resistance class Terminal box installation direction Number of poles/output Rating Outer cover structure Protection method Paint color Rotation direction Ambient conditions Altitude Ambient conditions Installation location Ambient conditions Humidity Ambient conditions Temperature Number of meddlers Meddling method
Top Runner Motor The Motor Neo100 Premium TFO-LK (LKK)-Part Number-TFO-LK (LKK)

TFO-LK (LKK)

Available upon quote

80M frame or more: 200V50Hz, 200/220/230V60Hz or 400V50Hz, 400/440/460V60Hz, etc.

Free from corrosive and explosive gases, vapors, condensation, and low dust

IS C 4213 Efficiency: JIS C 4034-30 Premium Efficiency (IE3)

2 poles 11kW or more: Direct connection only, 2 poles 7.5kW or less and 4, 6 poles: Direct connection / belt hooking common

155 (F) (Regarding temperature rise, the 112M frame and below are E rise, and the 132S~180M frame is B rise.)

Frame number 180M or less: Left when viewed from the load side Frame number 180L or more: Top

2 poles 0.75~200kW, 4 poles 0.75~300kW, 6 poles 0.75~250kW

S1 (continuous)

Totally enclosed external fan type IP44

Rigel Gray (Munsell 8.9Y5.1/0.3)

Counterclockwise when viewed from the load side (shaft end)

Altitude below 1,000m

Indoor

95%RH or less

132kW or less: -30~40℃, 150kW or more: -20~40℃

3.7kW or less 3 wires, 5.5kW or more 6 wires (Y-△ startable), 2 poles 22kW or more 4 poles 18.5kW or more 6 poles 15kW or more 12 wires (Y-△ startable), etc.

80M~160L are terminal block (screw) type, others are lug type.

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Three-Phase Motors Products

Other products of Fuji Electrode Industry Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Fuji Electrode Industry Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

6.9hrs


Company Review

5.0
  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.