Kien particle counterHandling Company
TranstecCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Measurement particle diameter | Suction flow rate | light source | The same clock number error difference | Data memory | display | Sample time | Hold time | Delay time | Measurement cycle | Battery | output | size | weight | Standard accessories | Measurement location ID | Housing material | Optional gas measurement | Printer | Flow rate adjustment | power supply | Operating environment | Storage environment | LED output | Flow rate | Material | pressure | Sampling diversion | Number of connections | Start measurement | Compatible models | Supported OS | Recommended hardware | Number of measurement points | Daily/Total processing | Alarm cleanliness |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Handheld Central Particle Counter MET ONE HHPC 2+ |
Available upon quote |
0.5 μm (fixed) |
2.83ℓ/minute |
Semiconductor laser |
less than 10, |
10,000 times |
3.5 inch color LCD panel (LED backlight type) |
1 second to 23 hours 59 minutes 59 seconds |
0 seconds to 23 hours 59 minutes 59 seconds |
3 seconds to 23 hours 59 minutes 59 seconds |
0 to 999 |
5 hours consecutive (3.5 hours charging) |
USB, Ethernet |
245 (H) x 99 (W) x 53 (D) * Excluding protrusions |
Approximately 690g |
Purge filter, Purge filter adapter, |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
Handheld Central Particle Counter MET ONE HHPC 3+ |
Available upon quote |
0.3 μm (fixed) |
2.83ℓ/minute |
Semiconductor laser |
less than 10, |
10,000 times |
3.5 inch color LCD panel (LED backlight type) |
1 second to 23 hours 59 minutes 59 seconds |
0 seconds to 23 hours 59 minutes 59 seconds |
3 seconds to 23 hours 59 minutes 59 seconds |
0 to 999 |
5 hours consecutive (3.5 hours charging) |
USB, Ethernet |
245 (H) x 99 (W) x 53 (D) * Excluding protrusions |
Approximately 690g |
Purge filter, Purge filter adapter, |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
Handheld Central Particle Counter MET ONE HHPC 6+ |
Available upon quote |
0.3/0.5/1.0/2.0/5.0/10.0 μm (simultaneous measurement of 6 gaps) |
2.83ℓ/minute |
Semiconductor laser |
"less than 10, |
10,000 times |
3.5 inch color LCD panel (LED backlight type) |
1 second to 23 hours 59 minutes 59 seconds |
0 seconds to 23 hours 59 minutes 59 seconds |
3 seconds to 23 hours 59 minutes 59 seconds |
0 to 999 |
5 hours consecutive (3.5 hours charging) |
USB, Ethernet |
245 (H) x 99 (W) x 53 (D) * Excluding protrusions |
Approximately 690g |
Purge filter, Purge filter adapter, |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
Kien Particle Counter MET ONE3413 |
Available upon quote |
0.3/0.5/1.0/3.0/5.0/10.0 μm |
28.3ℓ/minute |
Semiconductor laser |
28.3ℓ model: 10 % or less, |
5,000 times |
Color touch screen, 1/4VGA TFT |
1 second to 23 hours 59 minutes 59 seconds |
0 seconds to 23 hours 59 minutes 59 seconds |
6 seconds to 23 hours 59 minutes 59 seconds |
0-100 cycle |
6 hours (when 2 batteries are installed) |
USB client, USB host, Ethernet |
318 (W) x 254 (D) x 203 (H) mm |
7.55kg |
Speed suction probe, one Li-ion battery, |
0 to 999 |
Stainless steel housing |
nitrogen |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
Kien Particle Counter MET ONE3423 |
Available upon quote |
0.3/0.5/1.0/3.0/5.0/10.0 μm |
50ℓ/minute |
Semiconductor laser |
28.3ℓ model: 10 % or less, |
5,000 times |
Color touch screen, 1/4VGA TFT |
1 second to 23 hours 59 minutes 59 seconds |
0 seconds to 23 hours 59 minutes 59 seconds |
6 seconds to 23 hours 59 minutes 59 seconds |
0-100 cycle |
6 hours (when 2 batteries are installed) |
USB client, USB host, Ethernet |
318 (W) x 254 (D) x 203 (H) mm |
8.33kg |
Speed suction probe, one Li-ion battery, |
0 to 999 |
Stainless steel housing |
nitrogen |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
Kien Particle Counter MET ONE3415 |
Available upon quote |
0.5/1.0/2.0/3.0/5.0/10.0 or 25.0μm |
28.3ℓ/minute |
Semiconductor laser |
28.3ℓ model: 10 % or less, |
5,000 times |
Color touch screen, 1/4VGA TFT |
1 second to 23 hours 59 minutes 59 seconds |
0 seconds to 23 hours 59 minutes 59 seconds |
6 seconds to 23 hours 59 minutes 59 seconds |
0-100 cycle |
6 hours (when 2 batteries are installed) |
USB client, USB host, Ethernet |
318 (W) x 254 (D) x 203 (H) mm |
7.55kg |
Speed suction probe, one Li-ion battery, |
0 to 999 |
Stainless steel housing |
nitrogen |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
Kien Particle Counter MET ONE3425 |
Available upon quote |
0.5/1.0/2.0/3.0/5.0/10.0 or 25.0μm |
50ℓ/minute |
Semiconductor laser |
28.3ℓ model: 10 % or less, |
5,000 times |
Color touch screen, 1/4VGA TFT |
1 second to 23 hours 59 minutes 59 seconds |
0 seconds to 23 hours 59 minutes 59 seconds |
6 seconds to 23 hours 59 minutes 59 seconds |
0-100 cycle |
6 hours (when 2 batteries are installed) |
USB client, USB host, Ethernet |
318 (W) x 254 (D) x 203 (H) mm |
8.33kg |
Speed suction probe, one Li-ion battery, |
0 to 999 |
Stainless steel housing |
nitrogen |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
Kien Particle Counter MET ONE3445 |
Available upon quote |
0.5/1.0/2.0/3.0/5.0/10.0 μm |
100ℓ/minute |
Semiconductor laser |
less than 10, |
5,000 times |
Color touch screen, 1/4VGA TFT |
1 second to 23 hours 59 minutes 59 seconds |
0 seconds to 23 hours 59 minutes 59 seconds |
6 seconds to 23 hours 59 minutes 59 seconds |
0-100 cycle |
3 hours |
USB client, USB host, Ethernet, |
318 (W) x 254 (D) x 203 (H) mm |
8.65kg |
Correspondence suction probe, two Li-ion batteries, |
0 to 999 |
- | - |
Built -in heat printer |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
Kien Particle Counter MET ONE3411 |
Available upon quote |
0.1/0.2/0.3/0.5/1.0/5.0 μm |
28.3ℓ/minute |
HENE laser |
less than 10, |
5,000 times |
Color touch screen, 1/4VGA TFT |
1 second to 23 hours 59 minutes 59 seconds |
0 seconds to 23 hours 59 minutes 59 seconds |
6 seconds to 23 hours 59 minutes 59 seconds |
0-100 cycle |
3 hours |
USB client, USB host, Ethernet, |
330 (W) x 559 (D) x 229 (H) mm |
15.9kg |
Correspondence suction probe, two Li-ion batteries, |
0 to 999 |
Stainless steel housing |
nitrogen |
Built -in heat printer |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
Remote Particle Counter MET ONER4803 |
Available upon quote |
0.3/0.5μm |
2.83ℓ/minute |
Semiconductor laser |
less than 10, |
- | - | - | - | - | - | - |
RS-485 |
94 (W) x 38 (D) x 47 (H) mm |
0.3kg |
- | - | - | - | - |
Critical Olifice |
DC6V@ <250ma |
Temperature 12-29 ° C, humidity 20-95 % (without condensation) |
Temperature -40 to 70 ° C, humidity 0-95 % (without condensation) |
- | - | - | - | - | - | - | - | - | - | - | - | - | |
Remote Particle Counter MET ONER4805 |
Available upon quote |
0.5/5.0μm |
2.83ℓ/minute |
Semiconductor laser |
less than 10, |
- | - | - | - | - | - | - |
RS-485 |
94 (W) x 38 (D) x 47 (H) mm |
0.3kg |
- | - | - | - | - |
Critical Olifice |
DC6V@ <250ma |
Temperature 12-29 ° C, humidity 20-95 % (without condensation) |
Temperature -40 to 70 ° C, humidity 0-95 % (without condensation) |
- | - | - | - | - | - | - | - | - | - | - | - | - | |
Remote Particle Counter MET ONER4815 |
Available upon quote |
0.5/5.0μm |
28.3ℓ/minute |
Semiconductor laser |
less than 10, |
- | - | - | - | - | - | - |
RS-485 |
94 (W) x 38 (D) x 47 (H) mm |
0.3kg |
- | - | - | - | - |
Critical Olifice |
DC6V@ <250ma |
Temperature 12-29 ° C, humidity 20-95 % (without condensation) |
Temperature -40 to 70 ° C, humidity 0-95 % (without condensation) |
- | - | - | - | - | - | - | - | - | - | - | - | - | |
Remote Particle Counter MET ONER4903 |
Available upon quote |
0.3/0.5μm |
2.83ℓ/minute |
Semiconductor laser |
less than 10, |
- | - | - | - | - | - | - |
DC4-20MA |
94 (W) x 38 (D) x 47 (H) mm |
0.3kg |
- | - | - | - | - |
Critical Olifice |
DC6V@ <250ma |
Temperature 12-29 ° C, humidity 20-95 % (without condensation) |
Temperature -40 to 70 ° C, humidity 0-95 % (without condensation) |
- | - | - | - | - | - | - | - | - | - | - | - | - | |
Remote Particle Counter MET ONER4905 |
Available upon quote |
0.5/5.0μm |
2.83ℓ/minute |
Semiconductor laser |
less than 10, |
- | - | - | - | - | - | - |
DC4-20MA |
94 (W) x 38 (D) x 47 (H) mm |
0.3kg |
- | - | - | - | - |
Critical Olifice |
DC6V@ <250ma |
Temperature 12-29 ° C, humidity 20-95 % (without condensation) |
Temperature -40 to 70 ° C, humidity 0-95 % (without condensation) |
- | - | - | - | - | - | - | - | - | - | - | - | - | |
Remote Particle Counter MET ONER4915 |
Available upon quote |
0.5/5.0μm |
28.3ℓ/minute |
Semiconductor laser |
less than 10, |
- | - | - | - | - | - | - |
DC4-20MA |
94 (W) x 38 (D) x 47 (H) mm |
0.3kg |
- | - | - | - | - |
Critical Olifice |
DC6V@ <250ma |
Temperature 12-29 ° C, humidity 20-95 % (without condensation) |
Temperature -40 to 70 ° C, humidity 0-95 % (without condensation) |
- | - | - | - | - | - | - | - | - | - | - | - | - | |
Remote Particle Counter MET ONE6003 |
Available upon quote |
Standard 2 grain diameter option 4 grain size |
2.83ℓ/minute |
Semiconductor laser |
less than 10, |
- | - | - | - | - | - | - |
Ethernet, 4-20ma, Pulse, RS-232C, |
135.6 (W) x 89.3 (D) x 120.6 (H) mm |
0.82kg |
- | - |
SUS304 |
- | - |
Critical Olifice |
DC9-28V |
Temperature 10-32 ° C, humidity 5-95 % (without condensation) |
Temperature -40-70 ° C, humidity 5-98 % (without condensation) |
- | - | - | - | - | - | - | - | - | - | - | - | - | |
Remote Particle Counter MET ONE6005 |
Available upon quote |
Standard 2 grain diameter option 4 grain size |
2.83ℓ/minute |
Semiconductor laser |
less than 10, |
- | - | - | - | - | - | - |
Ethernet, 4-20ma, Pulse, RS-232C, |
135.6 (W) x 89.3 (D) x 120.6 (H) mm |
0.82kg |
- | - |
SUS304 |
- | - |
Critical Olifice |
DC9-28V |
Temperature 10-32 ° C, humidity 5-95 % (without condensation) |
Temperature -40-70 ° C, humidity 5-98 % (without condensation) |
- | - | - | - | - | - | - | - | - | - | - | - | - | |
Remote Particle Counter MET ONE6013 |
Available upon quote |
Standard 2 grain diameter option 4 grain size |
28.3ℓ/minute |
Semiconductor laser |
less than 10, |
- | - | - | - | - | - | - |
Ethernet, 4-20ma, Pulse, RS-232C, |
135.6 (W) x 89.3 (D) x 120.6 (H) mm |
0.82kg |
- | - |
SUS304 |
- | - |
Critical Olifice |
DC9-28V |
Temperature 10-32 ° C, humidity 5-95 % (without condensation) |
Temperature -40-70 ° C, humidity 5-98 % (without condensation) |
- | - | - | - | - | - | - | - | - | - | - | - | - | |
Remote Particle Counter MET ONE6015 |
Available upon quote |
Standard 2 grain diameter option 4 grain size |
28.3ℓ/minute |
Semiconductor laser |
less than 10, |
- | - | - | - | - | - | - |
Ethernet, 4-20ma, Pulse, RS-232C, |
135.6 (W) x 89.3 (D) x 120.6 (H) mm |
0.82kg |
- | - |
SUS304 |
- | - |
Critical Olifice |
DC9-28V |
Temperature 10-32 ° C, humidity 5-95 % (without condensation) |
Temperature -40-70 ° C, humidity 5-98 % (without condensation) |
- | - | - | - | - | - | - | - | - | - | - | - | - | |
Built -in remote party counter MET ONE6015P |
Available upon quote |
Standard 2 grain diameter option 4 gaps (Ethernet model) |
28.3ℓ/minute |
Semiconductor laser |
less than 10, |
- | - | - | - | - | - | - |
Ethernet, 4-20ma, Serial (RS232C/RS485), pulse |
170 (W) x 318 (D) x 102 (H) mm |
4.62kg |
- | - |
SUS304 |
- | - | - |
DC24V (up to 60W), AC100-240V (up to 150W) |
Temperature 10-32 ° C, humidity 5-95 % (without condensation) |
- |
Count alarm, sensor fail, communication failure, |
Automatic adjustment (built -in pressure sensor) |
- | - | - | - | - | - | - | - | - | - | - | |
High -pressure diffuser for MET ONE Particle Counter |
Available upon quote | - | - | - | - | - | - | - | - | - | - | - | - |
191 (W) x 57 (φ) mm |
- | - | - | - | - | - | - | - | - | - | - | - |
stainless |
30psi to 150psi |
2.83ℓ/minute type, 28.3ℓ/minute type |
- | - | - | - | - | - | - | - | |
Particle logger |
Available upon quote | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
One |
Can be stopped from the computer |
227 Series/237 Series/2400/2408/3400 Series |
Windows® 7, Windows® 2000Pro (SP1 or later), XP, Vista, InternetExplore® 5 or later |
Intel Pentium IV, 1GHz, 4GB or more empty hard disk memory 256MB, RS-232 port or USB port |
- | - | - | |
Particle Logger II |
Available upon quote | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Up to 6 units |
Can be stopped from the computer |
227 Series/237 Series/2400/2408/3400 Series |
Windows® 7, Windows® 2000Pro (SP1 or later), XP, Vista, InternetExplore® 5 or later |
Intel Pentium IV, 1GHz, 4GB or more empty hard disk memory 256MB, RS-232 port or USB port |
- | - | - | |
Particle View (Japanese version) |
Available upon quote | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
227 series, 237 series, 2400/2408, 3400 series |
Windows® 2000Pro (SP1 or later), XP, Vista and InternetExplore® 5 or later |
Intel Pentium IV, 1GHz, 4GB or more empty hard disk memory 256MB, RS-232 port or USB port |
- | - | - | |
Clean purifying intensive monitoring system monitoring software "CMS" |
Available upon quote | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
3400 series/manifold/R4800 series/6000 series |
- | - |
Clean cleaning + analog |
Average, maximum, minimum, and standard deviation in an arbitrary period, |
Upper limit 2 level (HIHI/hi), analog upper lower limit 1 level (HI/LO) |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
17.6hrs