Super small. Karman vortex flowmeter DKL-5L/20L for space-saving pipingHandling Company
Regal Joint Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply | Piping competition | Mass | Withstand voltage | Insulation resistance | Accuracy | Temperature measurement range | Current consumption | Flow range | Fluid temperature | Flow direction | Maximum working pressure | Transducer material | Response speed | Ambient temperature | Installation direction | Output | Fluid used | Body material | Cable | Alarm |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
DKL-5L |
Available upon quote |
DC 12V±5% or DC 24V±10% |
Φ10×8 |
110g |
Board case…between wires AC500V (1 minute) |
Board case…100MΩ or more between electronic boards JIS C 1302 |
F.S.±2.0% |
0 ~ 100℃ (optional) |
MAX 30mA (MAX 50mA when outputting 4 ~ 20mA current) |
1.0~5.0L/min |
0~90℃ |
Specified direction |
1MPa (less than 10kgf / square centimeter) |
PPS |
2sec |
0 ~ 40℃ (without freezing) |
Freedom |
0 ~ 10V or 4 ~ 20mA (Flow rate, temperature: optional) |
Industrial water, water, etc. |
SUS316 |
AWM20276 9 cores |
Open collector A or B (flow rate, temperature: optional) |