Flowmeter with relay output function Impeller type flowmeter FS-AR seriesHandling Company
Regal Joint Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply voltage (select 12V or 24V when ordering) | Piping diameter | Applicable fluid | Mass | Certification/standards etc. | Accuracy | Current consumption | Fluid temperature | Flow direction | Maximum working pressure | Connection material | Wetted parts material | Rated flow range | Ambient temperature | Mounting position | Protective structure | Relay output | Pulse output frequency | Pulse output (cannot be selected at the same time as current output) | Seal O-ring material | Cable | Orifice diameter | Analog output |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
FS-3AR |
Available upon quote |
DC 12V±5% or DC 24V±10% |
Rc 3/8 or Rc 1/2 |
Industrial water/water |
Approximately 380g |
RoHS Directive (SUS adapter specification only) |
±2.5% (F.S.) |
MAX 50mA (MAX 70mA when DC 1 ~ 5V, DC 4 ~ 20mA output) |
0 ~ 60℃ (No freezing or condensation) |
Both directions |
1.0MPa |
SUS or BsBM (Ni plating) |
Polyacetal/polyamide |
0.5~3L/min |
0 ~ 40℃ (No freezing or condensation) |
Freedom |
Drip-proofing of electronic circuits |
Maximum disallowed current: less than DC 2A |
0~43Hz |
Maximum disallowed current: less than DC 100mA |
Chloroprene rubber or fluororubber |
AWM20276 9 cores |
Φ5 |
DC 0 ~ 10V (voltage output) |