General-purpose leakage sensor RS-3000 series area detection type and individual detection type (NPN output) control unit-RS-3000C
General-purpose leakage sensor RS-3000 series area detection type and individual detection type (NPN output) control unit-Toyoko Chemical

General-purpose leakage sensor RS-3000 series area detection type and individual detection type (NPN output) control unit
Toyoko Chemical

Toyoko Chemical's Response Status

Response Rate

100.0%

Response Time

24.1hours

Relatively Fast Response


About This Product

The RS-3000 and 3500 series are sensors that detect leakage solutions using the refraction principle of light.

■ Characteristics

・ The RS-3000, 3500 series is a sensor that detects leakage solution using the principle of refraction of light. ・ Designed as the optimal flexion part shape so that low -viscous liquids can be detected quickly. ・ It can be widely used according to various sites, such as corrosion liquids such as acids and alkali, and small amounts and multiple leakage. ・ In order to support the device downsizing, the control unit for the equipment has been greatly reduced, enabling efficient dense arrangements, and the concentrated columned connector arrangement has reduced the wiring space. ・ The leakage detection of low -viscous liquids such as Florinato has also become quicker. -The output of the control unit is a "normal crosse" contact corresponding to the fail -safe design specification. -The control unit has been reduced, and the connection work has become one touch by connecting a connector, increasing the reliability of the wiring. ・ Din rails that are indispensable for the control unit can be installed in the standard case. ・ Since the installation of the detection unit and the disconnection are also detected, the operating abnormality of the sensor can be quickly known and contributed to the safety measures of the equipment. Equipped with a main sensor and a secondary sensor in the detection unit, and can also float from the mounting equipment abnormally. Because it is a PFA body as standard, it has a strong pharmaceutical properties and has a track record in drug solution supply equipment.

  • Product

    General-purpose leakage sensor RS-3000 series area detection type and individual detection type (NPN output) control unit

Share this product


270+ people viewing

Last viewed: 3 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

2 Models of General-purpose leakage sensor RS-3000 series area detection type and individual detection type (NPN output) control unit

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Supply voltage Current consumption current Number of input points LED display Output circuit Ambient temperature Case material weight Cable connection Installation method In case of wiring Applicable sensor
General-purpose leakage sensor RS-3000 series area detection type and individual detection type (NPN output) control unit-Part Number-RS-3000C

RS-3000C

Available upon quote

24V ± 10%

200 ma or less

8 points

Individual compatibility display to each point (8 points each x green / red 2 colors)
Normal: Green lighting
During leakage or mounting abnormality: red lighting

Relay contact x 1 point
DC24V 1A (resistance load)
Normal: Closed, when leakage or abnormality: Open, non -energized: Open

-10 ° C to 60 ° C

ABS resin

Approximately 100g

Input unit: connector x 8 points (with lock function)
Power / output unit: 1 connector x 1 point (with lock function)
No special tools are required for the connector wiring.

DIN rail compatible screws can be stopped

Disconnected detection

RS-3000FA, RS-3000FAP

General-purpose leakage sensor RS-3000 series area detection type and individual detection type (NPN output) control unit-Part Number-RS-3500C

RS-3500C

Available upon quote

24V ± 10%

200 ma or less

8 points

Individual compatibility display to each point (8 points each x green / red 2 colors)
Normal: Green lighting
During leakage or mounting abnormality: red lighting

Relay contact x 1 point
DC24V 1A (resistance load)
Normal: Closed, when leakage or abnormality: Open, non -energized: Open

-10 ° C to 60 ° C

ABS resin

Approximately 100g

Input unit: connector x 8 points (with lock function)
Power / output unit: 1 connector x 1 point (with lock function)
No special tools are required for the connector wiring.

DIN rail compatible screws can be stopped

Disconnected detection

RS-3500FA, RS-3500FAP

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Water Detection Sensors Products

Other products of Toyoko Chemical

Reviews shown here are reviews of companies.


View more products of Toyoko Chemical

About Company Handling This Product

Response Rate

100.0%


Response Time

24.1hrs


Company Review

4.5

Company Overview

Toyoko Kagaku Co., Ltd. established in 1952, and based in Kawasaki-city, Japan, is a manufacturer and supplier...

See More

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree